PubMed Health⌕ Search

Biomedical subjects

Günter Schreier

Publications and source records attributed to Günter Schreier.

3 recordsLinked to original sources

Cardiac anisotropy: is it negligible regarding noninvasive activation time imaging?

The aim of this study was to quantify the effect of cardiac anisotropy in the activation-based inverse problem of electrocardiography. Differences of the patterns of simulated body surface potential maps for isotropic and anisotropic conditions were investigated with regard to activation time (AT) imaging of ventricular depolarization. AT maps were estimated by solving the nonlinear inverse ill-posed problem employing spatio-temporal regularization. Four different reference AT maps (sinus rhythm, right-ventricular and septal pacing, accessory pathway) were calculated with a bidomain theory based anisotropic finite-element heart model in combination with a cellular automaton. In this heart model a realistic fiber architecture and conduction system was implemented. Although the anisotropy has some effects on forward solutions, effects on inverse solutions are small indicating that cardiac anisotropy might be negligible for some clinical applications (e.g., imaging of focal events) of our AT imaging approach. The main characteristic events of the AT maps were estimated despite neglected electrical anisotropy in the inverse formulation. The worst correlation coefficient of the estimated AT maps was 0.810 in case of sinus rhythm. However, all characteristic events of the activation pattern were found. The results of this study confirm our clinical validation studies of noninvasive AT imaging in which cardiac anisotropy was neglected.

Action Potentials↗

Computerized heart allograft-recipient monitoring: a multicenter study.

Computerized heart allograft recipient monitoring (CHARM) is a unique concept of patient surveillance after heart transplantation (HTx), based on the evaluation of intramyocardial electrograms (IEGMs) recorded non-invasively with telemetric pacemakers. Previous open, single-center studies had indicated a high correlation between CHARM results and clinical findings. The present study was initiated to assess the suitability of CHARM for monitoring the absence of rejection in a blind, multicenter context. During the HTx procedure, telemetric pacemakers and two epimyocardial leads were implanted in 44 patients at four European HTx centers. IEGMs during pacing were recorded and transferred via the Internet to the CHARM computer center, for automatic data processing and extraction of diagnostically relevant information, i.e., the maximum slew rate of the descending part of the repolarization phase of the ventricular evoked response (VER T-slew). The study period comprised the first 6 months after HTx, during which the transplant centers were blind to the CHARM results. A single threshold diagnosis model was prospectively defined to assess the ability of the VER T-slew to indicate clinically significant rejection, which was defined as an endomyocardial biopsy (EMB) grade greater than or equal to 2, according to the grading system of the International Society for Heart and Lung Transplantation. All EMB slides from three centers were reviewed blind by the pathologist of the fourth center in order that agreement among the histological diagnoses at the various centers could be assessed. Totals of 839 follow-ups and 366 EMBs were obtained in 44 patients. Thirty-seven patients were alive at the end of the study period. Age at HTx, EMB grade distribution, and rejection prevalence varied significantly between the centers. Review of the EMB results showed considerable differences with respect to classification of significant rejection. Comparison of average VER T-slew values with and without rejection in the 15 patients who exhibited both states revealed significantly lower values under the influence of rejection (97+/-13% vs 79+/-15%, P<0.0001). Twenty out of the 25 cases with significant rejection were correctly identified by VER T-slew values below a threshold of 98% (sensitivity =80%, specificity =50%, negative predictive value =97%, positive predictive value =11%; P<0.0005). Of the EMBs, 48% could have been saved if the diagnosis model had been used to indicate the need for EMB. A high negative predictive value for the detection of cases with significant rejection has been obtained in a prospective, blind, multicenter study. The presented method can, therefore, be used to supplement patient monitoring after HTx non-invasively, in particular to indicate the need for EMBs. In centers with patient management similar to the ones who participated in the study, this may allow a reduction in the number of surveillance EMBs.

Decision Making, Computer-Assisted↗

Development of a new QT algorithm with heterogenous ECG databases.

An algorithm for automated QT interval assessments has been developed and evaluated using the PhysioNet QT database and the electrocardiogram multilead database (2 collections of electrocardiograms with different characteristics, eg, numbers of leads and expert annotations). QRS onset and coarse T offset detection was based on the definition of a short time window, within which the range of signal amplitudes was calculated and compared to given threshold values. The final position of T offset was based on a combination of 3 methods: decreasing thresholds, multiple tangents, and a model based approach. The evaluation was based on the comparison of a waveform marker as computed automatically, and those of the human experts. Mean and standard deviation of those differences compared well to other algorithms and to inter-expert variations. Waveform marker detection was successful in at least 98% of the annotated beats in both databases, thus, indicating the robustness of the proposed method.

Algorithms↗