PubMed Health⌕ Search

Biomedical subjects

Gabriel P Lopez

Publications and source records attributed to Gabriel P Lopez.

15 recordsLinked to original sources

Thermoresponsive transport through ordered mesoporous silica/PNIPAAm copolymer membranes and microspheres.

Thermosensitive inorganic-organic hybrid polymers and gels can be used for controlled molecular transport in a variety of applications that require robust, mechanically stable materials. Silica and poly(N-isopropylacrylamide) (PNIPAAm) precursors were copolymerized in the presence of surfactant supramolecular assemblies to form hybrid gels with ordered nanostructure. This method was less complicated and results in enhanced reversible transport properties compared to previous approaches noted herein. In this study, the thermoresponsive polymer, PNIPAAm, was incorporated into polymerizing silica networks using the coupling agent 3-methacryloxypropyltrimethoxysilane. The hydration transition of PNIPAAm associated with its lower critical solution temperature (LCST) in aqueous solution was retained in the hydrated silica matrices and was used to control the permeability of membranes and molecular release behavior of particles. This report presents new methods for formation of hybrid silica/PNIPAAm membranes and particles, characterization of these materials, and documentation of reversible molecular transport properties of these new hybrid materials.

Acrylic Resins↗

Using bicellar mixtures to form supported and suspended lipid bilayers on silicon chips.

Bicellar mixtures, planar lipid bilayer assemblies comprising long- and short-chain phosphatidylcholine lipids in suspension, were used to form supported lipid bilayers on flat silicon substrate and on nanotextured silicon substrates containing arrays of parallel troughs (170 nm wide, 380 nm deep, and 300 nm apart). Confocal fluorescence and atomic force microscopies were used to characterize the resulting lipid bilayer. Formation of a continuous biphasic undulating lipid bilayer membrane, where the crests and troughs corresponded to supported and suspended lipid bilayer regions, is demonstrated. The use of interferometric lithography to fabricate nanotexured substrates provides an advantage over other nanotextured substrates such as nanoporous alumina by offering flexibility in designing different geometries for suspending lipid bilayers.

Lipid Bilayers↗

Supramolecular photochemical self-assemblies for fluorescence "turn on" and "turn off" assays for chem-bio-helices.

We describe the development of an optical sensing system for the high-throughput screening (HTS) of a broad range of biological molecules, whole cells, organisms and pathogens, and illustrate the technology applications by a hyaluronidase enzyme activity assay as a specific example. At the core of the technology described in this paper, is the exciton concept that is relevant to molecular aggregation. J-aggregates of cyanine dyes have a narrower, red-shifted absorption band compared to monomer. We demonstrate that self-assembly may be driven by the helicogenic nature of the cyanine dye, converting the linear polymers of hyaluronic acid or carboxymethyl cellulose into supramolecular helical assemblies. This self-assembly is accompanied by an intense, sharp, red-shifted J-aggregate fluorescence. We utilized this property to develop an assay for the enzyme hyaluronidase, based upon the concept of "scaffold destruction," whereby the disruption/destruction of the hyaluronic acid polymer by hyaluronidase is accompanied by an attenuation of light emission from the J-aggregate. The extent of light attenuation provides an index of hyaluronidase activity. Other polymers of carbohydrates, proteins, nucleic acids and chemical polymers (such as the carbon nanotube) might provide a similar scaffold for helicogenic dyes upon which molecular aggregation can occur. A key feature of these assays is that they are label-free.

Fluorescence↗

Superquenching as a detector for microsphere-based flow cytometric assays.

BACKGROUND: Fluorescent conjugated polymers display high fluorescence quantum yields and enhanced sensitivity to quenching (superquenching) by oppositely charged quenchers through energy or electron transfer. Fluorescent polymers and their quenchers are used in bead-based biosensor applications where the polymers are coated on particles. In this work, we investigate a detection method that utilizes superquenching on microspheres, which can be used for flow cytometric assays. METHODS: Microspheres were coated with the fluorescent cationic polyelectrolyte poly(p-phenylene-ethynylene) (PPE), and its superquenching by 9,10-anthraquinone-2,6-disulfonic acid (AQS) was examined by fluorometric methods in presence and in absence of a barrier to superquenching in the form of an anionic lipid bilayer. RESULTS: Flow cytometry detected superquenching of PPE on microspheres (MS-PPE) by AQS where high levels of reduction in fluorescence were observed. Adding different concentrations of AQS to MS-PPE yielded a Stern-Volmer quenching constant of 0.8x10(6) M-1. While forming an anionic lipid bilayer around the MS-PPE acted as a barrier to superquenching by AQS, disrupting the lipid bilayer allowed superquenching to take place. CONCLUSIONS: The sensitivity of flow cytometry in detecting fluorescence of microspheres and the amplified quenching sensitivity of fluorescent conjugated polymers both offer advantages over other fluorometric methods and conventional quenching detection. This study used superquenching of fluorescent polymers as a new tool in flow cytometry, thus combining the advantages offered by both method and detector. In addition, we employed the formation and the disruption of a supported lipid bilayer in mediating superquenching to offer new biosensing applications.

Anthraquinones↗

Electrostatic potential and electroosmotic flow in a cylindrical capillary filled with symmetric electrolyte: analytic solutions in thin double layer approximation.

The electrostatic potential in a capillary filled with electrolyte is derived by solving the nonlinear Poisson-Boltzmann equation using the method of matched asymptotic expansions. This approach allows obtaining an analytical result for arbitrary high wall potential if the double layer thickness is smaller than the capillary radius. The derived expression for the electrostatic potential is compared to numerical solutions of the Poisson-Boltzmann equation and it is shown that the agreement is excellent for capillaries with radii greater or equal to four times the electrical double layer thickness. The knowledge of the electrostatic potential distribution inside the capillary enables the derivation of the electroosmotic velocity flow profile in an analytical form. The obtained results are applicable to capillaries with radii ranging from nanometers to micrometers depending on the ionic strength of the solution.

Journal Article↗

Dynamics of fluorescence dequenching of ostrich-quenched fluorescein biotin: a multifunctional quantitative assay for biotin.

We describe a simple and rapid quantitative assay for biotin and biotin conjugates. The assay is based on the kinetic analysis of the enhancement of fluorescence of streptavidin/fluorescein biotin complexes in the presence of biotin. The kinetic response of fluorescence enhancement is proportional to the concentration of biotin. Standard calibration curves based on the kinetic response are obtained and detection limits of approximately 10(-9)M are established. Because the assay is amenable for use in small volumes of 5-50 microL or bead-based assays, the detection limits can be extended to the femtomole range. Since the assay depends on kinetic analysis, routine quantitation can be achieved without reference to standard curves. The dynamic aspects allow the assay to be extended to a broader range of applications including its use as an indicator of reagent mixing in laminar-flow assays carried out in microfluidic devices.

Biotin↗

Microchannel protein separation by electric field gradient focusing.

A microchannel device is presented which separates and focuses charged proteins based on electric field gradient focusing. Separation is achieved by setting a constant electroosmotic flow velocity against step changes in electrophoretic velocity. Where these two velocities are balanced for a given analyte, the analyte focuses at that point because it is driven to it from all points within the channel. We demonstrate the separation and focusing of a binary mixture of bovine serum albumin and phycoerythrin. The device is constructed of intersecting microchannels in poly(dimethylsiloxane)(PDMS) inlaid with hollow dialysis fibers. The device uses no exotic chemicals such as antibodies or synthetic ampholytes, but operates instead by purely physical means involving the independent manipulation of electrophoretic and electroosmotic velocities. One important difference between this apparatus and most other devices designed for field-gradient focusing is the injection of current at discrete intersections in the channel rather than continuously along the length of a membrane-bound separation channel.

Dimethylpolysiloxanes↗

Small-volume rapid-mix device for subsecond kinetic analysis in flow cytometry.

BACKGROUND: Rapid-mix flow cytometry has emerged as a powerful tool for mechanistic analysis of ligand binding, cell response, and molecular assembly. Although progress has come from improving sample delivery capabilities, little attention has been paid to the volumetric requirements associated with precious biological reagents. METHODS: By using programmable syringes, valves, and other fluidic components, we created a modular, precisely regulated rapid-mix device for the delivery of small-volume samples to the flow cytometer. The device was tested using a bead-based assay in which the binding kinetics between native biotin and fluorescein biotin-bearing beads were characterized. RESULTS: Bead suspensions and reagents paired in 35- to 45-microl aliquots were efficiently mixed by the device and delivered to the flow cytometer. Kinetic data associated with the fluorescein biotin beads were analyzed and used to calibrate the performance characteristics of the device in terms of sample delivery and mixing efficiency. CONCLUSION: The rapid-mix device is capable of detecting subsecond kinetics of biological reactions using microliter volume of samples. Dimensions of the device have been minimized, and the quantitative aspects of sample delivery and analysis have been optimized. Further, the modular design has been optimized for adaptation to a variety of experimental protocols.

Biotin↗

Near-simultaneous and real-time detection of multiple analytes in affinity microcolumns.

A miniaturized immunoassay system based on beads in poly(dimethylsiloxane) microchannels for analyzing multiple analytes has been developed. The method involves real-time detection of soluble molecules binding to receptor-bearing microspheres, sequestered in affinity column format inside a microfluidic channel. Identification and quantitation of analytes occurs via direct fluorescence measurements or fluorescence resonance energy transfer. A preliminary account of this work based on single-analyte format has been published in this journal (Buranda, T.; Huang, J.; Perez-Luna, V. H.; Schreyer, B.; Sklar, L. A.; Lopez, G. P. Anal. Chem. 2002, 74, 1149-1156). We have extended the work to a multianalyte model system composed of discrete segments of beads that bear distinct receptors. Near-simultaneous and real-time detection of diverse analytes is demonstrated. The importance of this work is established in the exploration of important factors related to the design, assessment, and utility of affinity microcolumn sensors. First, beads derivatized with surface chemistry suitable for the attachment of fluorescently labeled biomolecules of interest are prepared and characterized in terms of functionality and receptor site densities by flow cytometry. Second, calibrated beads are incorporated in microfluidic channels. The analytical device that emerges replicates the basic elements of affinity chromatography with the advantages of microscale and real-time direct measurement of bound analyte on beads rather than the indirect determination from eluted sample typical of affinity chromatography. In addition, the two-compartment analysis of the assay data as demonstrated in single-analyte columns provides a template upon which the dynamics of multiple-analyte assays can be characterized using existing theoretical models and be tested experimentally. The assay can potentially detect subfemtomole quantities of protein with high signal-to-noise ratio and a large dynamic range spanning nearly 4 orders of magnitude in analyte concentration in microliter to submicroliter volumes of analyte fluid. The approach has the potential to be generalized to a host of bioaffinity assay methods including analysis of protein complexes (e.g., biomolecular indicators of diseases). Proof-of-principle analytes include FLAG peptide and carcinoembryonic antigen detected at physiologically relevant concentration levels.

Carcinoembryonic Antigen↗

Effect of substratum surface chemistry and surface energy on attachment of marine bacteria and algal spores.

Two series of self-assembled monolayers (SAMs) of omega-substituted alkanethiolates on gold were used to systematically examine the effects of varying substratum surface chemistry and energy on the attachment of two model organisms of interest to the study of marine biofouling, the bacterium Cobetia marina (formerly Halomonas marina) and zoospores of the alga Ulva linza (formerly Enteromorpha linza). SAMs were formed on gold-coated glass slides from solutions containing mixtures of methyl- and carboxylic acid-terminated alkanethiols and mixtures of methyl- and hydroxyl-terminated alkanethiols. C. marina attached in increasing numbers to SAMs with decreasing advancing water contact angles (theta(AW)), in accordance with equation-of-state models of colloidal attachment. Previous studies of Ulva zoospore attachment to a series of mixed methyl- and hydroxyl-terminated SAMs showed a similar correlation between substratum theta(AW) and zoospore attachment. When the hydrophilic component of the SAMs was changed to carboxylate, however, the profile of attachment of Ulva was significantly different, suggesting that a more complex model of interfacial energetics is required.

Bacterial Adhesion↗

Microchip countercurrent electroseparation.

We report a microchip-based method for separating charged molecules according to electrophoretic mobility. The method is based on opposed electroosmotic, electrophoretic and convective forces. Similar to isoelectric focusing, solute can be accumulated into stationary zones, but without use of ampholytes. The method of "microchip countercurrent electroseparation" described here has potential application in the design of microfluidic separation chips.

Journal Article↗

Functional nanocomposites prepared by self-assembly and polymerization of diacetylene surfactants and silicic acid.

Conjugated polymer/silica nanocomposites with hexagonal, cubic, or lamellar mesoscopic order were synthesized by self-assembly using polymerizable amphiphilic diacetylene molecules as both structure-directing agents and monomers. The self-assembly procedure is rapid and incorporates the organic monomers uniformly within a highly ordered, inorganic environment. By tailoring the size of the oligo(ethylene glycol) headgroup of the diacetylene-containing surfactant, we varied the resulting self-assembled mesophases of the composite material. The nanostructured inorganic host altered the diacetylene polymerization behavior, and the resulting nanocomposites show unique thermo-, mechano-, and solvatochromic properties. Polymerization of the incorporated surfactants resulted in polydiacetylene (PDA)/silica nanocomposites that were optically transparent and mechanically robust. Molecular modeling and quantum calculations and (13)C spin-lattice relaxation times (T(1)) of the PDA/silica nanocomposites indicated that the surfactant monomers can be uniformly organized into precise spatial arrangements prior to polymerization. Nanoindentation and gas transport experiments showed that these nanocomposite films have increased hardness and reduced permeability as compared to pure PDA. Our work demonstrates polymerizable surfactant/silica self-assembly to be an efficient, general approach to the formation of nanostructured conjugated polymers. The nanostructured inorganic framework serves to protect, stabilize, and orient the polymer, mediate its performance, and provide sufficient mechanical and chemical stability to enable integration of conjugated polymers into devices and microsystems.

Acetylene↗

Biomolecular recognition on well-characterized beads packed in microfluidic channels.

We describe a new approach for the analysis of biomolecular recognition in microfluidic channels. The method involves real-time detection of soluble molecules binding to receptor-bearing microspheres, sequestered in affinity column format inside a microfluidic channel. Identification and quantitation of analytes occurs via direct fluorescence measurements or fluorescence resonance energy transfer (FRET). We establish a model system that detects the FLAG epitope. The assay can potentially detect subfemtomole quantities of antibody with a high signal-to-noise ratio and a large dynamic range spanning nearly 4 orders of magnitude in analyte concentration in microliter-to-submicroliter volumes of analyte fluid. Kinetic and equilibrium constants for the reaction of this receptor-ligand pair are obtained through modeling of kinetic responses of the affinity microcolumn and are consistent with those obtained by flow cytometry. Because of the correlation between kinetic and equilibrium data obtained for the microcolumns, quantitative analysis can be done prior to the steady-state end point of the recognition reaction. This method has the promise of combining the utility of affinity chromatography with the advantage of direct, quantitative, and real-time analysis and the cost-effectiveness of microanalytical devices. The approach has the potential to be generalized to a host of bioaffinity assay methods including analysis of protein complexes and molecular assembly and microsystem-based multianalyte determinations.

Antibodies, Monoclonal↗

Diazo coupling method for covalent attachment of proteins to solid substrates.

We describe a process for covalently linking proteins to glass microscope slides and microbeads in a manner that optimizes the reactivity of the immobilized proteins and that is suitable for high-throughput microarray and flow cytometry analysis. The method involves the diazo coupling of proteins onto activated self-assembled monolayers formed from p-aminophenyl trimethoxysilane. Proteins immobilized by this method maintained bioactivity and produced enhanced levels of protein-protein interaction, low background fluorescence, and high selectivity. The binding of immobilized proteins to their specific binding partner was analyzed quantitatively and successfully correlated with solution concentrations. Diazotized surfaces bound more efficiently to proteins containing a hexahistidine tag than those without a his-tag. Moreover, significantly higher reactivity of the immobilized his-tagged proteins was observed on diazotized surfaces than on amine-terminated surfaces. Results suggest that his-tagged proteins are immobilized by reaction of the his-tag with the diazotized surface, thus offering the possibility for preferential orientation of covalently bound proteins.

Animals↗

Dual closed-loop, optoelectronic, auto-oscillatory detection circuit for monitoring fluorescence lifetime-based chemical sensors and biosensors.

We present a new detection instrument for sensor measurements based on excited-state fluorescence lifetimes. This system consists of a primary optoelectronic loop containing a resonance-type rf amplifier, a modulatable fluorescence-excitation light source, a fiber optic feedback loop (with a gap for a fluorescent sensor), and a photomultiplier tube. A secondary, phase-feedback optoelectronic circuit consists of a long-wavelength-pass optical filter, a second photomultiplier tube, a photodiode, an electronic phase detector, a dc amplifier, and an electronic phase shifter (inserted into the main loop). This phase-feedback circuit is new with respect to our previous work. Under the appropriate conditions, the main loop exhibits self-oscillations, manifesting themselves as sinusoidal rf modulation of light intensity. The phase-feedback circuit detects the modulation phase shift resulting from the finite excited-state lifetimes of a fluorophore. As the excited state lifetime changes, the phase shift from the electronic phase shifter also changes, which results in a shift in self-oscillation frequency. The detection system uses self-oscillation frequency as the detection parameter and has excellent resolution with respect to changes in excited-state lifetime ( approximately 1 ps). (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Biosensing Techniques↗