PubMed Health⌕ Search

Biomedical subjects

Gabriel von Allmen

Publications and source records attributed to Gabriel von Allmen.

2 recordsLinked to original sources

Virtopsy: postmortem minimally invasive angiography using cross section techniques--implementation and preliminary results.

Postmortem investigation is increasingly supported by Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). This led to the idea to implement a noninvasive or minimally invasive autopsy technique. Therefore, a minimally invasive angiography technique becomes necessary, in order to support the vascular cross section diagnostic. Preliminary experiments investigating different contrast agents for CT and MRI and their postmortem applicability have been performed using an ex-vivo porcine coronary model. MSCT and MRI angiography was performed in the porcine model. Three human corpses were investigated using minimally invasive MSCT angiography. Via the right femoral artery a plastic tube was advanced into the aortic arch. Using a flow adjustable pump the radiopaque contrast agent meglumine-ioxithalamate was injected. Subsequent MSCT scanning provided an excellent anatomic visualization of the human arterial system including intracranial and coronary arteries. Vascular pathologies such as calcification, stenosis and injury were detected. Limitations of the introduced approach are cases of major vessel injury and cases that show an advanced stage of decay.

Angiography↗

Grading airway stenosis down to the segmental level using virtual bronchoscopy.

OBJECTIVE: To assess the sensitivity of noninvasive virtual bronchoscopy based on multirow detector CT scanning in detecting and grading central and segmental airway stenosis using flexible bronchoscopic findings as the reference standard. MATERIALS AND METHODS: In a blinded controlled trial, multirow detector CT virtual bronchoscopy and flexible bronchoscopy were used to search for and grade airway stenosis in 20 patients. CT scan data were obtained with a multirow detector CT scanner using 4 x 1 mm collimation. Flexible bronchoscopy findings were graded by a pulmonologist and served as the reference standard for 176 central airway regions (ie, trachea, main bronchi, and lobar bronchi) and 302 segmental airway regions. The extent of airway narrowing was categorized as grade 0 (no narrowing), grade 1 (< 50%), or grade 2 (> or =50%). RESULTS: Flexible bronchoscopy revealed 30 stenoses in the central airways and 10 in the segmental airways. Virtual bronchoscopy detected 32 stenoses in the central airways (sensitivity, 90.0%; specificity, 96.6%; accuracy, 95.5%) and 22 in the segmental airways (sensitivity, 90.0%; specificity, 95.6%; accuracy, 95.5%). The number of false-positive findings was higher in the segmental airways (13 false-positive findings) than in the central airways (5 false-positive findings), which caused a lower positive predictive value for the segmental airways (40.9%) than for the central airways (84.4%). Flexible and virtual bronchoscopic gradings correlated better for central airway stenosis (r = 0.87) than for segmental airway stenosis (r = 0.61). CONCLUSION: Although a high sensitivity was found for the detection of both central and segmental airway stenosis, the number of false-positive findings was higher for segmental airways. However, noninvasive multirow detector CT virtual bronchoscopy enables high-resolution endoluminal imaging of the airways down to the segmental bronchi.

Aged↗