Biomechanical properties of human articular cartilage under compressive loads.

The function of articular cartilage is to support and distribute loads and to provide lubrication in the diarthrodial joints. Cartilage function is described by proper mechanical and rheological properties, strain and depth-dependent, which are not completely assessed. Unconfined and confined compression are commonly used to evaluate the Young's modulus (E) and the aggregate modulus (H(A)), respectively. The Poisson's ratio (nu) can be calculated indirectly from the equilibrium compression data, or using the biphasic indentation technique; it has recently been optically evaluated by using video microscopy during unconfined compression. The transient response of articular cartilage during confined compression depends on its permeability k; a constant value of k can be easily identified by a simple analytical model of confined compression tests, whereas more complex models or direct measurements (permeation tests) are needed to study the permeability dependence on deformation. A poroelastic finite element model of articular cartilage was developed for this purpose. The elastic parameters (E,nu) of the model were evaluated performing unconfined compression creep tests on human articular cartilage disks, whereas k was identified from the confined test response. Our combined experimental and computational method can be used to identify the parameters that define the permeability dependence on deformation, as a function of depth from articular surface.

Adaptation, Physiological↗

The effect of media perfusion on three-dimensional cultures of human chondrocytes: integration of experimental and computational approaches.

This work examines the effect of perfusion on human mature articular chondrocytes cultured on synthetic biodegradable scaffolds (DegraPol). Human chondrocytes were isolated, seeded on the scaffolds and subjected to perfused culture at a flow rate of 0.5 ml/min, corresponding to an average inlet fluid velocity of 44 microm/s, with flow inversion every 1 minute. The flow was imposed at the construct surface in some constructs, it was forced through the construct thickness in other constructs and was absent in the static controls. We compared cell viability and morphology and we evaluated material properties of the constructs at 1 month of culture. Thickness-perfused constructs showed significantly higher material properties and roughly a two-fold cell viability, when compared both to surface-perfused constructs and to static controls. Chondrocytes maintained a phenotypic morphology in all experiments, probably favoured by a limited cell-scaffold interaction. Biosynthetic activity could be demonstrated only in the bioreactor-cultured constructs. In this experimental model, a bi-directional flow of culture medium was applied to the cells at a macroscopic level and computational modelling was used to quantify the fluid-dynamic environment induced on the cells at a microscopic level. This method may be used to quantify the effects of fluid-dynamic shear on the growth modulation of tissue-engineered cartilage constructs, to potentially enhance tissue growth in vitro.

Biomechanical Phenomena↗

Computational fluid dynamics in the evaluation of hemodynamic performance of cavopulmonary connections after the Norwood procedure for hypoplastic left heart syndrome.

OBJECTIVE: Computational fluid dynamics have been used to study the hemodynamic performance of surgical operations, resulting in improved design. Efficient designs with minimal energy losses are especially important for cavopulmonary connections. The purpose of this study was to compare hydraulic performance between the hemi-Fontan and bidirectional Glenn procedures, as well as the various types of completion Fontan operations. METHODS: Three-dimensional models were constructed of typical hemi-Fontan and bidirectional Glenn operations according to anatomic data derived from magnetic resonance scans, angiocardiograms, and echocardiograms. Boundary conditions were imposed, and fluid dynamics were calculated from a mathematic code. Power losses, flow distribution to each lung, and pressures were measured at three predetermined levels of pulmonary arteriolar resistance. Models of the lateral tunnel, total cavopulmonary connection, and extracardiac conduit completion Fontan operations were constructed, and power losses, total flow distribution, vena caval and pulmonary arterial pressures, and flow distribution of inferior vena caval return were calculated. RESULTS: The hemi-Fontan and bidirectional Glenn procedures performed nearly identically, with similar power losses and nearly equal flow distributions to each lung at all levels of pulmonary arteriolar resistance. However, the lateral tunnel Fontan procedure as performed after the hemi-Fontan operation had lower power losses (6.9 mW, pulmonary arteriolar resistance 3 units) than the total cavopulmonary connection (40.5 mW) or the extracardiac conduit (42.9 mW), although the inclusion of an enlargement patch toward the right in the total cavopulmonary connection was effective in reducing the difference (10.0 mW). Inferior vena caval flow to the right lung was 52% for the lateral tunnel, compared with 19%, 30%, 19%, and 15% for the total cavopulmonary connection, total cavopulmonary connection with right-sided enlargement patch, extracardiac conduit, and extracardiac conduit with a bevel to the left lung, respectively. CONCLUSIONS: According to these methods, the hemi-Fontan and bidirectional Glenn procedures performed equally well, but important differences in energy losses and flow distribution were found after the completion Fontan procedures. The superior hydraulic performance of the lateral tunnel Fontan operation after the hemi-Fontan procedure relative to any other method may be due to closer to optimal caval offset achieved in the surgical reconstruction.

Cardiac Surgical Procedures↗

Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: the influence of the inferior caval anastomosis.

Fluid dynamics of Total Cavo-Pulmonary Connection (TCPC) were studied in 3-D models based on real dimensions obtained by Magnetic Resonance (MR) images. Models differ in terms of shape (intra- or extra-cardiac conduit) and cross section (with or without patch enlargement) of the inferior caval (IVC) anastomosis connection. Realistic pulsatile flows were submitted to both the venae cavae, while porous portions were added at the end of the pulmonary arteries to reproduce the pulmonary afterload. The dissipated power and the flow distribution into the lungs were calculated at different values of pulmonary arteriolar resistances (PAR). The most important results are: i) power dissipation in different TCPC designs is influenced by the actual cross sectional area of the IVC anastomosis and ii) the inclusion of a patch minimizes the dissipated power (range 4-13 mW vs. 14-56 mW). Results also show that the perfusion of the right lung is between 15% and 30% of the whole IVC blood flow when the PAR are evenly distributed between the right and the left lung.

Blood Flow Velocity↗

Pressure drops in a distensible model of end-to-side anastomosis in systemic-to-pulmonary shunts.

The modified Blalock-Taussig shunt is a surgical procedure used as a palliation to treat complex congenital heart defects. It consists of an interposing prosthetic tube between the innominate/subclavian artery and the right pulmonary artery. Previous experience indicates that the pressure drop across the shunt is affected by the pulmonary pressure at the distal anastomosis combined with the distensibility of the anastomosis. In this study, a computational fluid-structure interaction approach is presented to investigate the haemodynamic behaviour. Steady-state fluid dynamics and structural analyses were carried out using commercial codes based on the finite element method (FIDAP and ABAQUS) coupled by means of a purposely-developed procedure to transfer boundary conditions. Both prosthetic tube and artery walls were characterised by non-linear material properties. Three different pulmonary pressures (2, 5 and 15 mmHg) and two volume flow rates (0.4 and 0.8 l/min) were investigated. Results indicate that the effects of distensibility at the distal anastomosis on the shunt pressure drop are relevant only when the distal anastomosis on the shunt pressure drop are relevant only when the distal anastomosis is not fully distended, which occurs when the pulmonary pressure is lower than 5 mmHg.

Algorithms↗

The effect of fixture neck design in a realistic model of dental implant: a finite element approach.

The aim of this work is to develop an accurate finite element model able to reproduce a standard experimental set-up for the evaluation of mechanical failure of a dental implant system. The considered system is composed of a fixture, an abutment and a connecting screw. We analysed the behaviour of the implant system considering three different designs of the fixture, in order to establish which one provides the better mechanical behaviour. After the definition of the numerical models, loading conditions were selected in order to reproduce the same stress state found in previous mechanical failure tests. Preloading and functional loading conditions were simulated. The analysis of the numerical results shows that the structure yielding is due to the fixture neck plastic deformation, that increases the load eccentricity and then the bending stress on the connecting screw. Only slight differences were found between the three implant systems in the amount and distribution of stress. The model reproduces properly the implant systems and the experimental set-up. The goodness of the model can be summarised as: realistic geometrical structure, elastoplastic model for the material description, correct definition of the contacts and the existing tolerance among the different system components, reproduction of the preloading stress condition. The present study permitted to define a valid procedure for the realization of numerical models of implant systems.

Computer Simulation↗

Poroelastic numerical modelling of natural and engineered cartilage based on in vitro tests.

The mechanisms underlying the ability of articular cartilage to withstand and distribute the loads applied across diarthrodial joints have been widely studied. Experimental tests have been done under several configurations to reveal the tissue response to mechanical stimuli, and theoretical models have been developed for the interpretation of the experimental results. The experiments demonstrated that the tissue is non-linear with strain, both in tension and in compression, non-linear with direction of stimulus, anisotropic in tension and compression, non-homogeneous with depth, resulting in depth dependent mechanical properties, and presents fluid dependent and fluid independent viscoelasticity. None of the models up to now developed is able to describe the whole set of responses of such a complex tissue. The purpose of this study was to develop a combined experimental-numerical approach for the proper description of the cartilage response under confined and unconfined compression. We defined a series of experimental tests to be performed on disks of natural and engineered cartilage and we developed a numerical model for cartilage, based on the biphasic theory, which potentially includes the tension-compression non-linearity, the strain non-linearity and the fluid independent viscoelasticity. The model successfully simulated the confined and unconfined compression experiments performed on disks of natural and engineered cartilage, and was also used to identify parameters of difficult experimental evaluation, such as the collagen stiffness and the permeability. In conclusion, the use of our model in combination with biomechanical experimental testing seems a valuable tool to analyze the mechanical properties of natural cartilage and the biofunctionality of tissue engineered cartilage.

Aged↗