PubMed Health⌕ Search

Biomedical subjects

Gabriele Schulz

Publications and source records attributed to Gabriele Schulz.

4 recordsLinked to original sources

Slow blood sampling from an umbilical artery catheter prevents a decrease in cerebral oxygenation in the preterm newborn.

OBJECTIVE: Blood sampling from an umbilical artery catheter (UAC) placed in a high position (thoracal 6-9) has the potential to produce clinically significant changes in cerebral blood flow and, thereby, in cerebral oxygenation. This may contribute to cerebral impairment in preterm newborn infants. Therefore, we set up a study to determine the effects of different sampling speeds through a UAC on cerebral oxygenation in preterm infants. METHODS: Thirty pairs of measurements were conducted on 20 preterm infants (median gestational age: 30.14 weeks; median birth weight: 1170 g). For each infant, 2 blood samplings (both 2.3 mL, including flush volume) through the UAC in high position were taken at 2 different speeds (20 and 40 seconds) in alternating sequence. Cerebral oxygenation was measured noninvasively by near-infrared spectroscopy. Concentration changes in cerebral oxygenated hemoglobin (O2Hb) and deoxygenated hemoglobin (HHb), along with the tissue oxygenation index (TOI; O2Hb/[O2Hb + HHb] x 100), were recorded while blood was withdrawn and subsequently reinfused. RESULTS: A significant decrease in O2Hb and TOI occurred during blood sampling within 20 seconds (median DeltaO2Hb: -1.5 micromol/L; range: -4.1-2.3; median DeltaTOI: -0.6%; range: -6.3-2.3), whereas HHb increased (median DeltaHHb: 0.4 micromol/L, range: -1.1-3.9). No significant change was found in O2Hb, HHb, and TOI when sampling time was extended to 40 seconds. CONCLUSION: Our results show that blood withdrawal over 20 seconds from a UAC in high position significantly decreases cerebral O2Hb and TOI in preterm infants. Prolonging sampling time to 40 seconds can prevent this phenomenon.

Blood Specimen Collection↗

Liver tissue oxygenation as measured by near-infrared spectroscopy in the critically ill child in correlation with central venous oxygen saturation.

OBJECTIVE: To evaluate the clinical usefulness of near-infrared spatially resolved spectroscopic quantitative assessment of liver tissue oxygenation for simple, non-invasive estimation of global tissue oxygenation in critically ill neonates and children. DESIGN: Prospective observational clinical study. SETTING: A tertiary multidisciplinary neonatal and paediatric intensive care unit (23 beds). PATIENTS: One hundred neonates and children consecutively admitted to the paediatric intensive care unit. MEASUREMENTS AND RESULTS: Near-infrared spectroscopic single-point assessment of liver tissue oxygenation index (TOI(Liver)) was compared with global tissue oxygenation as measured by central venous oxygen saturation (SvO(2)) and derived haemodynamic parameters. Data were compared using linear and multiple regression analysis. Overall correlation between TOI(Liver)and SvO(2) was good ( r=0.72, p<0.0001). Multivariable regression revealed that SvO(2) alone explained 51% of the observed variance of TOI(Liver). However, our data demonstrated large inter-individual differences between SvO(2) and TOI(Liver) values. CONCLUSION: Near-infrared spatially resolved spectroscopic quantitative measurement of liver tissue oxygenation correlates well with SvO(2) in critically ill neonates and children. Large inter-individual SvO(2) to TOI(Liver) differences may prevent its use for non-invasive single-point estimation of global tissue oxygenation. Further clinical studies are required to validate the method with other regional and global haemodynamic parameters and to evaluate its clinical use for continuous non-invasive haemodynamic monitoring.

Catheterization, Central Venous↗

Transcutaneously measured near-infrared spectroscopic liver tissue oxygenation does not correlate with hepatic venous oxygenation in children.

PURPOSE: To compare transcutaneous near-infrared spectroscopic (NIRS) measured liver tissue oxygenation with hepatic vein oxygen saturation (SvhO2) in children undergoing cardiac catheterization. METHODS: A NIRS optode (containing an emitter and a receiver of near-infrared light) was placed directly below the right costal arch above the palpable liver in 40 children aged 0.02 to 7.28 yr (median: 1.8 yr). Spatially resolved spectroscopic measured tissue oxygenation index (TOI) was recorded using the NIRO-300. Paired blood samples from the hepatic vein were taken under radiological control for determination of SvhO2 in a co-oxymeter. TOI values were compared with hepatic vein oxygenation, with simultaneously obtained arterial oxygen saturation (SaO2), inferior vena cava SO2 and hemoglobin concentration using simple linear and multi-regression analysis. RESULTS: TOI values ranged from 35% to 73% (58.6 +/- 8.4%); SvhO2 from 32% to 80% (58.4 +/- 14.4%), and arterial SO2 from 54% to 100% (90.0 +/- 11.4%). TOI and hepatic vein oxygen saturation failed to correlate (r = 0.052/P = 0.752). A regression model containing arterial saturation (Delta R2 = 0.177) and the ratio of pulmonary to systemic resistance (Delta R2 = 0.095) explained 27.3% of the observed variance in TOI. In this model, hepatic vein oxygen saturation was no longer significant; explaining only 3.4% of the variance. No other variable retained a significant association. CONCLUSION: Transcutaneously measured NIRS tissue oxygenation with an optode placed over the palpable liver does not correlate with SvhO2. The value is dominated by non-hepatic variables such as arterial saturation and vascular resistances.

Child↗

Placebo-controlled study of the mite allergen-reducing effect of tannic acid plus benzyl benzoate on carpets in homes of children with house dust mite sensitization and asthma.

We studied the effect of a spray containing 1% benzyl benzoate, an acaricide, and 1% tannic acid ('Lowal'; a protein-denaturing substance), on concentrations of major allergens from house dust mite (HDM) species Dermatophagoides pteronyssinus and D. farinae (Der p 1 and Der f 1, respectively) in carpets. In a double-blind, placebo-controlled study with crossover design, 30 homes of children with HDM sensitization and asthma were included. All houses showed > or = 400 ng/g of Der p 1 + Der f 1 in carpet dust. The first treatment was performed on day 0 (group 1 active treatment, n = 15; group 2 placebo treatment, n = 15). After 2 and 8 weeks, dust samples were collected for quantification of mite allergens. After a 2-week washout period, the second treatment was performed (group 1 placebo treatment; group 2 active treatment). Again, carpet dust was collected after 2 and 8 weeks. Twenty-two of 30 families completed the trial: 14/15 in group 1 and eight of 15 in group 2. On day 0, there was no significant difference in mite allergen exposure between group 1 and group 2 (1,498 vs. 2,239 ng/g of Der p 1 + Der f 1, respectively). In group 1, the geometric mean for the difference of mite allergen concentration comparing day 0 and week 6 was 196 ng/g (95% CI: -7,161 and 8,401) for the first treatment (active) and 15 ng/g (95% CI: -1,079 and 1,292) for the second treatment (control). In group 2, the difference was 66 ng/g (95% CI: -398 and 1,515) for the first treatment (control) and 609 ng/g (95% CI: 186 and 9,264) for the second treatment (active). Comparing placebo and active treatment in total, there was a significant decrease following placebo treatment after 14 days (p = 0.026). After 8 weeks, active treatment was superior to placebo treatment (p = 0.049), but the allergen reduction achieved was < 20% (median 1,500 ng/g on day 0 vs. 1,250 ng/g after 8 weeks). We conclude that the slight mite allergen reduction on carpets achieved by the treatment with 'Lowal' is unlikely to achieve worthwhile clinical benefit either in the treatment of mite-sensitive patients or in primary or secondary prophylaxis.

Antigens, Dermatophagoides↗