Proteomic Characterization of the Rhesus Macaque Lens Nucleus: Similarity to Human Lens, Age Effects on Protein Solubility, and Trends in Post-Translational Modifications.

PURPOSE: Proteomes of lens nuclei from young (4 years old) and old (15-16 years old) rhesus macaques (Macaca mulatta) were analyzed to determine similarity of the proteomic profile to that of human lenses, age-related differences in protein solubility, and association of various post-translational modifications with age and protein solubility. METHODS: Lens core proteins were separated into water-soluble and water-insoluble fractions using aqueous buffer and centrifugation. The water-insoluble fraction was solubilized using sodium dodecyl sulfate (SDS). Proteins were processed using S-trap columns, and peptide digests were analyzed using high-resolution, label-free data-dependent acquisition (DDA) proteomics. Open modification searches were performed using MSFragger to identify possible post-translational modifications (PTMs). The number of modified peptide tandem mass spectra confidently assigned to samples by age or solubility were compared to find PTMs with statistically significant count differences. RESULTS: The overall proteomic profile of rhesus macaque lenses was very similar to human lenses, consisting of 80.2% crystallins, 1.1% beaded filament proteins, and 18.7% other proteins. The crystallin fraction consisted of 27% alpha crystallins, 67.6% beta/gamma crystallins, and 5.4% taxon-specific psi crystallin. Glycolytic enzymes, beta/gamma crystallins, and a few glutathione-related enzymes were found to have age-related shifts to the water-insoluble fraction. There were significant differences in deamidation, dioxidation, carbamylation, carboxymethylation, and trioxidation based on age and/or solubility of proteins. CONCLUSIONS: These data indicate a high level of conformity between rhesus macaque and human lens proteomes, and a few key differences. We identified several age-related differences in protein solubility and PTM that may contribute to lens pathology.

Animals↗

Glaucoma detection with matrix and standard achromatic perimetry.

BACKGROUND: Matrix perimetry is a new iteration of frequency-doubling technology (FDT) which uses a smaller target size in the standard achromatic perimetry presentation pattern. AIM: To compare the performance of matrix and Swedish interactive thresholding algorithm (SITA) perimetry in detecting glaucoma diagnosed by structural assessment. DESIGN: Prospective cross-sectional study. METHODS: 76 eyes from 15 healthy subjects and 61 consecutive glaucoma suspects and patients with glaucoma were included. All patients underwent optic nerve head (ONH) photography, SITA and matrix perimetries, and optical coherence tomography (OCT) within a 6-month period. Glaucoma diagnosis was established by either glaucomatous optic neuropathy or OCT by assessing retinal nerve fibre layer (RNFL) thickness. Mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test and cluster of abnormal testing locations were recorded from matrix and SITA perimetries. RESULTS: Similar correlations were observed with matrix and SITA perimetry MD and PSD with either cup-to-disc ratio or OCT mean RNFL. The area under the receiver operating characteristic (AROC) curves of MD and PSD for discriminating between healthy and glaucomatous eyes ranged from 0.69 to 0.81 for matrix perimetry and from 0.75 to 0.77 for SITA perimetry. There were no significant differences among any corresponding matrix and SITA perimetry AROCs. CONCLUSIONS: Matrix and SITA perimetries had similar capabilities for distinguishing between healthy and glaucomatous eyes regardless of whether the diagnosis was established by ONH or OCT-RNFL assessment.

Adult↗

Glaucoma detection with the Heidelberg retina tomograph 3.

PURPOSE: To compare the ability of the Heidelberg retina tomograph version 3 (HRT 3) and HRT version 2 (HRT 2) to discriminate between healthy and glaucomatous eyes. DESIGN: Retrospective cross-sectional study. PARTICIPANTS: Seventy-one eyes of 71 healthy volunteers and 50 eyes of 50 glaucoma patients were studied. The average visual field mean deviation of the glaucoma group was -6.03+/-5.78 dB. INTERVENTION: All participants had comprehensive ocular examinations, perimetry, and HRT scanning within 6 months. HRT 2 data were analyzed using HRT 3 software without modifying the disc margin. MAIN OUTCOME MEASURES: Discrimination capabilities between healthy and glaucomatous eyes were determined by areas under the receiver operating characteristics (AROCs) curves. Comparisons between corresponding AROCs obtained by HRT 2 and HRT 3 analyses were performed using the nonparametric DeLong method. Agreement between classifications as defined by the different analysis methods was quantified by kappa analysis. RESULTS: The individual stereometric parameters with the best discrimination were linear cup/disc ratio (AROC = 0.897; 95% confidence interval [CI], 0.836-0.958) for standard HRT 3 analysis and horizontal retinal nerve fiber layer curvature (0.905) for HRT 3 glaucoma probability score (GPS) analysis. Areas under the receiver operating characteristics for discrimination between glaucomatous and healthy eyes of the overall classification by HRT 2 Moorfields regression analysis (MRA), HRT 3 MRA, and GPS were 0.927 (95% CI, 0.877-0.977), 0.934 (0.888-0.980), and 0.880 (0.812-0.948), respectively. The difference between the 3 AROCs was not significant (P = 0.44). The agreement between HRT 2 and HRT 3 overall MRA classification was good (kappa = 0.70; CI, 0.59-0.80) with HRT 3 tending to report more abnormalities than HRT 2 analysis. The agreement between overall HRT 3 MRA and overall GPS was kappa = 0.58 (CI, 0.45-0.70). CONCLUSIONS: The glaucoma discriminating ability of the new HRT 3 software is similar to that of the previous generation HRT 2. The GPS analysis showed promising results in differentiating between healthy and glaucomatous eyes without the need for subjective operator input.

Adult↗

Comparison of visual field defects using matrix perimetry and standard achromatic perimetry.

PURPOSE: To compare visual field (VF) defects found by Swedish interactive thresholding Algorithm (SITA) perimetry and Matrix perimetry, a new VF device that utilizes frequency doubling technology in a 24-2 test pattern. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Fifty eyes from 50 subjects with SITA field defects were recruited for an observational study. METHODS: Swedish Interactive Threshold Algorithm and Matrix VF testing were performed on patients from a glaucoma practice. To evaluate the learning effect on the performance of the VF, we tested subsets of each group who had previous experience with standard automated perimetry (SAP). MAIN OUTCOME MEASURES: Test duration, mean threshold, mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test, and number of abnormal points on the pattern deviation plot were evaluated for each device. RESULTS: Test duration was significantly shorter for Matrix (SITA, 357.0+/-85.6 seconds; Matrix, 319.5+/-16.5 seconds; P = 0.0002, paired t-test). Thirty-six percent of eyes with SITA VF defects showed a normal Matrix field. In 30 of 32 eyes (94%) where both devices showed VF defects, the defects were congruent. Mean threshold value was significantly lower with Matrix compared to SITA (P<0.0001, paired t-test), as was MD (-5.34+/-5.42 dB, -4.14+/-5.29 dB, respectively; P = 0.03, paired t-test). There was no significant difference in PSD between the 2 devices (P = 0.78, paired t-test). Matrix delineated significantly smaller (P = 0.005, Wilcoxon's test) and deeper (P<0.001, Wilcoxon's test) defects than those found with SITA. Similar results were observed in the subgroups with prior SAP experience. CONCLUSIONS: The Matrix examination did not detect 36% of abnormal SITA fields. Matrix field defects were smaller and deeper than those appearing in SITA perimetry.

Adult↗

Persistence of Cloquet's canal in normal healthy eyes.

PURPOSE: Optic nerve head (ONH) structural imaging with state-of-the-art, high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT). DESIGN: Observational cohort study. METHODS: ONH centered 3-dimensional (94,371,840 voxel measurements in a 6- x 6- x 1.4-mm tissue volume) hsUHR-OCT data were obtained in one eye from each of six males and nine females normal healthy volunteers (40 +/- 9 years of age). The presence of structures projecting anteriorly from the disk into the vitreous was noted. RESULTS: Structures were noted in 14 of 15 (93%) examined eyes, emanating from the rim of the ONH at the nasal inferior sector, presenting as thin tissue meandering into the vitreous. CONCLUSIONS: Previous technologies provided limited visualization of ONH structures. The ability to scan the entire disk using 3-dimensional OCT (3D-OCT) in a high-density raster pattern reveals a high frequency of persistence of Cloquet's canal in the normal healthy eye.

Adult↗

Effect of corneal drying on optical coherence tomography.

PURPOSE: To determine the effect of corneal drying on the outcome of optical coherence tomography (OCT). DESIGN: Cohort study. PARTICIPANTS: Seventeen normal participants (mean age, 39+/-12 years). METHODS: Subjects underwent a series of peripapillary circular StratusOCT scans (version 3.0; Carl Zeiss Meditec, Inc., Dublin, CA) in a randomly selected eye. Baseline scan sets were acquired, and thereafter, blinking was prevented by taping the eyelid. Eyelid taping was immediately followed by 6 to 8 serial scan sets, each separated by 20 seconds. After removing the eyelid tape, 3 additional scans were acquired at 1, 2, and 4 minutes of blinking freely. MAIN OUTCOME MEASURES: The analyzed outcome measures were scan quality as defined by signal-to-noise ratio (SNR) and signal strength (SS) provided by the built-in OCT software and mean nerve fiber layer (NFL) thickness. RESULTS: Significant reductions in SNR, SS, and NFL were noted at each scanning point in the drying phase (for each, P<0.015, paired t test) except for NFL thickness measurements acquired at 140 and 160 seconds. The reduction in NFL thickness exceeded the 95% confidence limit of the reported reproducibility error of StratusOCT after 15 seconds of corneal drying. After 1 and 2 minutes of blinking freely, there was still a significant reduction in NFL thickness compared with the baseline value, which was no longer evident at the 4-minute scan. CONCLUSIONS: Corneal dryness affects OCT scan quality and measured NFL thickness after a short exposure time. It is recommended to instruct those who are scanned to blink frequently or to instill artificial tears.

Adult↗

Retinal nerve fiber layer assessment using optical coherence tomography with active optic nerve head tracking.

PURPOSE: To develop an eye-motion-tracking optical coherence tomographic (OCT) method and assess its effect on image registration and nerve fiber layer (NFL) thickness measurement reproducibility. METHODS: A system capable of tracking common fundus features based on reflectance changes was integrated into a commercial OCT unit (OCT II; Carl Zeiss Meditec, Inc., Dublin, CA) and tested on healthy subjects and patients with glaucoma. Twenty successive peripapillary NFL scans were obtained with tracking and 20 without tracking, for 40 images in each session for each eye. Subjects participated in one session on three different days. Composite OCT scans and composite fundus images were generated for assessment of eye tracking. NFL thickness measurement reproducibility was also assessed. RESULTS: Seven healthy and nine glaucomatous eyes of 16 subjects were recruited. A qualitative assessment of composite OCT scans and composite fundus images showed little motion artifact or blurring along edges and blood vessels during tracking; however, those structures were less clearly defined when tracking was disengaged. There was no significant reproducibility difference with and without tracking in both intra- and intersession NFL measurement SD calculations in any location. The mean retinal pixel SD was significantly smaller with tracking than without (490.9 +/- 19.3 microm vs. 506.4 +/- 31.8 microm, P = 0.005, paired t-test). CONCLUSIONS: A retinal-tracking system was successfully developed and integrated into a commercial OCT unit. Tracking OCT improved the consistency of scan registration, but did not influence NFL thickness measurement reproducibility in this small sample study.

Adult↗

Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular pathology.

OBJECTIVE: To compare ultrahigh-resolution optical coherence tomography (UHR OCT) with standard-resolution OCT for imaging macular diseases, develop baselines for interpreting OCT images, and identify situations where UHR OCT can provide additional information on disease morphology. DESIGN: Cross-sectional study. PARTICIPANTS: One thousand two eyes of 555 patients with different macular diseases including macular hole, macular edema, central serous chorioretinopathy, age-related macular degeneration (AMD), choroidal neovascularization, epiretinal membrane, retinal pigment epithelium (RPE) detachment, and retinitis pigmentosa. METHODS: A UHR ophthalmic OCT system that achieves 3-microm axial image resolution was developed for imaging in the ophthalmology clinic. Comparative studies were performed with both UHR OCT and standard 10-microm-resolution OCT. Standard scanning protocols of 6 radial 6-mm scans through the fovea were obtained with both systems. Ultrahigh-resolution OCT and standard-resolution OCT images were correlated with standard ophthalmic examination techniques (dilated ophthalmoscopy, fluorescein angiography, indocyanine green angiograms) to assess morphological information contained in the images. MAIN OUTCOME MEASURES: Ultrahigh-resolution and standard-resolution OCT images of macular pathologies. RESULTS: Correlations of UHR OCT images, standard-resolution images, fundus examination, and/or fluorescein angiography were demonstrated in full-thickness macular hole, central serous chorioretinopathy, macular edema, AMD, RPE detachment, epiretinal membrane, vitreal macular traction, and retinitis pigmentosa. Ultrahigh-resolution OCT and standard-resolution OCT exhibited comparable performance in differentiating thicker retinal layers, such as the retinal nerve fiber, inner and outer plexiform, and inner and outer nuclear. Ultrahigh-resolution OCT had improved performance differentiating finer structures or structures with lower contrast, such as the ganglion cell layer and external limiting membrane. Ultrahigh-resolution OCT confirmed the interpretation of features, such as the boundary between the photoreceptor inner and outer segments, which is also visible in standard-resolution OCT. The improved resolution of UHR OCT is especially advantageous in assessing photoreceptor morphology. CONCLUSIONS: Ultrahigh-resolution OCT enhances the visualization of intraretinal architectural morphology relative to standard-resolution OCT. Ultrahigh-resolution OCT images can provide a baseline for defining the interpretation of standard-resolution images, thus enhancing the clinical utility of standard OCT imaging. In addition, UHR OCT can provide additional information on macular disease morphology that promises to improve understanding of disease progression and management.

Adult↗

Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma.

OBJECTIVES: To longitudinally evaluate optical coherence tomography (OCT) peripapillary retinal nerve fiber layer thickness measurements and to compare these measurements across time with clinical status and automated perimetry. METHODS: Retrospective evaluation of 64 eyes (37 patients) of glaucoma suspects or patients with glaucoma participating in a prospective longitudinal study. All participants underwent comprehensive clinical assessment, visual field (VF) testing, and OCT every 6 months. Field progression was defined as a reproducible decline of at least 2 dB in VF mean deviation from baseline. Progression of OCT was defined as reproducible mean retinal nerve fiber layer thinning of at least 20 mum. RESULTS: Each patient had a median of 5 usable OCT scans at median follow-up of 4.7 years. The difference in the linear regression slopes of retinal nerve fiber layer thickness between glaucoma suspects and patients with glaucoma was nonsignificant for all variables; however, Kaplan-Meier survival curve analysis demonstrated a higher progression rate by OCT vs VF. Sixty-six percent of eyes were stable throughout follow-up, whereas 22% progressed by OCT alone, 9% by VF mean deviation alone, and 3% by VF and OCT. CONCLUSIONS: A greater likelihood of glaucomatous progression was identified by OCT vs automated perimetry. This might reflect OCT hypersensitivity or true damage identified by OCT before detection by conventional methods.

Aged↗

Comparison of three optical coherence tomography scanning areas for detection of glaucomatous damage.

PURPOSE: Several cross-sectional studies have demonstrated the capability of optical coherence tomography (OCT) to detect glaucomatous changes. OCT enables posterior pole scanning of three regions: macula, peripapillary, and optic nerve head (ONH). This study compared the ability of each region to detect glaucomatous damage. DESIGN: Retrospective observational cross-sectional study. METHODS: The study included 37 normal (37 subjects) and 37 glaucomatous eyes (26 subjects) that had comprehensive ocular examination, reliable and reproducible Swedish interactive thresholding algorithm standard 24-2 perimetry, and Stratus OCT scanning of macula, peripapillary, and ONH regions on the same visit. Optical nerve head (ONH) appearance did not form part of the inclusion criteria. The main outcome measure, was area under receiver operating characteristic curves (AROCs) that was calculated for each scanning region for distinguishing between normal and glaucomatous eyes. RESULTS: The highest AROCs for distinguishing between groups were for ONH parameters (rim area = 0.97, horizontal integrated rim width = 0.96, vertical integrated rim area = 0.95) and peripapillary nerve fiber layer (NFL) thickness (0.94) followed by macular volume and thickness (both 0.80). A statistically significant difference existed in ONH and NFL AROCs when compared with macular AROCs (P < or = .007, for both) CONCLUSIONS: OCT ONH and NFL parameters provided similar discrimination capabilities between healthy eyes and those of glaucoma patients and superior discrimination capabilities when compared with macular parameters.

Algorithms↗

Ultrahigh-resolution optical coherence tomography in glaucoma.

OBJECTIVE: Optical coherence tomography (OCT) has been shown to be a valuable tool in glaucoma assessment. We investigated a new ultrahigh-resolution OCT (UHR-OCT) imaging system in glaucoma patients and compared the findings with those obtained by conventional-resolution OCT. DESIGN: Retrospective comparative case series. PARTICIPANTS: A normal subject and 4 glaucoma patients representing various stages of glaucomatous damage. TESTING: All participants were scanned with StratusOCT (axial resolution of approximately 10 mum) and UHR-OCT (axial resolution of approximately 3 microm) at the same visit. MAIN OUTCOME MEASURE: Comparison of OCT findings detected with StratusOCT and UHR-OCT. RESULTS: Ultrahigh-resolution OCT provides a detailed cross-sectional view of the scanned retinal area that allows differentiation between retinal layers. These UHR images were markedly better than those obtained by the conventional-resolution OCT. CONCLUSIONS: Ultrahigh-resolution OCT provides high-resolution images of the ocular posterior segment, which improves the ability to detect retinal abnormalities due to glaucoma.

Adult↗

Macular segmentation with optical coherence tomography.

PURPOSE: To develop a software algorithm to perform automated segmentation of retinal layer structures on linear macular optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Inc., Dublin, CA) scan images and to test its performance in discriminating normal from glaucomatous eyes in comparison with conventional circumpapillary nerve fiber layer (cpNFL) thickness measurement. METHODS: Four layer structures within the retina were defined: the macular nerve fiber layer (mNFL), the inner retinal complex (IRC; retinal ganglion cell [RGC] layer + inner plexiform and nuclear layers), outer plexiform layer (OPL), and outer retinal complex (ORC; outer nuclear layer + photoreceptor layer). Normal and glaucomatous eyes underwent fast macular map and fast NFL OCT scans. Linear macular images were analyzed using the developed algorithm, and the results were compared with the cpNFL thickness measurement. RESULTS: Forty-seven subjects (23 normal and 24 with glaucoma) were analyzed. mNFL, cpNFL, IRC, and the total retinal thicknesses were significantly greater in normal than in glaucomatous eyes (P < or = 0.0002; Wilcoxon), whereas OPL thickness did not show a significant difference (P = 0.46). ORC thickness was significantly greater in glaucomatous than normal eyes (P = 0.035). Areas under the receiver operator characteristic curve (AROCs) for discriminating normal from glaucomatous eyes were highest with mNFL + IRC (0.97) and lowest with OPL (0.56). AROCs for OPL and ORC were significantly smaller than those for mNFL, IRC, mNFL+IRC, and cpNFL (P < or = 0.01). AROCs for IRC, mNFL + IRC, and cpNFL were significantly larger than for retinal thickness (P < or = 0.049). Among the best-performing parameters (mNFL, IRC, mNFL + IRC, and cpNFL) there was no significant difference in AROCs (P > or = 0.15). CONCLUSIONS: The newly developed macular segmentation algorithm described herein demonstrated its ability to quantify objectively the glaucomatous damage to RGCs and NFL and to discriminate between glaucomatous and normal eyes. Further algorithm refinement and improvements in resolution and image quality may yield a more powerful methodology for clinical glaucoma evaluation.

Algorithms↗

Optical coherence tomography machine learning classifiers for glaucoma detection: a preliminary study.

PURPOSE: Machine-learning classifiers are trained computerized systems with the ability to detect the relationship between multiple input parameters and a diagnosis. The present study investigated whether the use of machine-learning classifiers improves optical coherence tomography (OCT) glaucoma detection. METHODS: Forty-seven patients with glaucoma (47 eyes) and 42 healthy subjects (42 eyes) were included in this cross-sectional study. Of the glaucoma patients, 27 had early disease (visual field mean deviation [MD] > or = -6 dB) and 20 had advanced glaucoma (MD < -6 dB). Machine-learning classifiers were trained to discriminate between glaucomatous and healthy eyes using parameters derived from OCT output. The classifiers were trained with all 38 parameters as well as with only 8 parameters that correlated best with the visual field MD. Five classifiers were tested: linear discriminant analysis, support vector machine, recursive partitioning and regression tree, generalized linear model, and generalized additive model. For the last two classifiers, a backward feature selection was used to find the minimal number of parameters that resulted in the best and most simple prediction. The cross-validated receiver operating characteristic (ROC) curve and accuracies were calculated. RESULTS: The largest area under the ROC curve (AROC) for glaucoma detection was achieved with the support vector machine using eight parameters (0.981). The sensitivity at 80% and 95% specificity was 97.9% and 92.5%, respectively. This classifier also performed best when judged by cross-validated accuracy (0.966). The best classification between early glaucoma and advanced glaucoma was obtained with the generalized additive model using only three parameters (AROC = 0.854). CONCLUSIONS: Automated machine classifiers of OCT data might be useful for enhancing the utility of this technology for detecting glaucomatous abnormality.

Adult↗

Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields.

PURPOSE: To investigate the structure-function relationship between optical coherence tomography (OCT) macular retinal and peripapillary nerve fiber layer (NFL) thickness and automated visual field (VF) findings. DESIGN: Cross-sectional observational study. METHODS: Retrospective institutional study where 150 consecutive eyes (101 subjects) from a glaucoma service were included. All the participants had full ophthalmic evaluation, VF testing and prototype OCT scanning at the same visit. Orthogonal OCT macular analysis was obtained to maximize the sampling of the area of interest. Pearson age-adjusted correlation was determined between macular retinal thickness and peripapillary NFL thickness. Area under the receiver operator characteristics (AROC) curves for the association between macular retinal thickness and peripapillary NFL thickness and VF findings were calculated in a subgroup of eyes without VF defect and eyes with VF defect confined to one hemifield. RESULTS: The correlation between macular retinal and peripapillary NFL measurements ranged between r =.27 to.54 for quadrants,.44 to.55 for hemiretina, and.52 for the overall mean. Areas under the receiver operator characteristics for macular thickness were higher in areas corresponding to the VF defect location than the noncorresponding locations. Areas under the receiver operator characteristics for peripapillary NFL thickness were higher than for the macular retinal thickness. Including both macular retinal thickness and peripapillary NFL thickness measurements in the logistic regression model yielded AROCs (range:.69 -.77) similar to those found for the peripapillary NFL alone. CONCLUSION: Macular retinal thickness, as measured by OCT, was capable of detecting glaucomatous damage and corresponded with peripapillary NFL thickness; however, peripapillary NFL thickness had higher sensitivity and specificity for the detection of VF abnormalities.

Aged↗

Contact transscleral neodymium:yttrium-aluminum-garnet laser cyclophotocoagulation Long-term outcome.

PURPOSE: Contact transscleral neodymium:yttrium-aluminum-garnet (Nd:YAG) laser cyclophotocoagulation (CYC) is a treatment option for advanced glaucoma refractory to alternative treatments. This study determined the long-term efficacy and risks of contact transscleral Nd:YAG laser CYC. DESIGN: A prospective study was performed with patients with advanced, uncontrolled glaucoma who received CYC from 1988 through 1989. PARTICIPANTS: Records for 68 eyes of 64 patients were obtained and reviewed for the 10-year follow-up. METHODS: A transscleral continuous-wave Nd:YAG laser was used for photocoagulation of the ciliary body. MAIN OUTCOME MEASURES: Intraocular pressure (IOP), visual acuity, and second intervention. Failure was defined as the need for second intervention, IOP of more than 25 mmHg, or IOP of less than 3 mmHg. RESULTS: The mean follow-up period was 5.85+/-4.0 years (range, 0.1-10 years). The mean preoperative IOP of 36.3+/-10.1 mmHg decreased to 22.6+/-11.3 mmHg at 1 year of follow-up (P<0.001). The mean postoperative IOP at 5 years was 21.8+/-13.3 mmHg (P<0.001) and was 18.9+/-12.2 mmHg at 10 years of follow-up (P<0.001). A second intervention after CYC was required in 30 eyes (44.1%). Six eyes (8.8%) with initial visual acuity of counting fingers or worse progressed to no light perception, and 5 of 8 eyes (62.5%) with visual acuity better than 20/200 lost 2 or more Snellen lines. Hypotony developed in 3 eyes (4.4%). Overall, the failure rate by 10 years of follow-up was 51.5% (35/68 eyes). CONCLUSIONS: Cyclophotocoagulation resulted in a significant reduction of IOP after surgery at 1, 5, and 10 years of follow-up; however, 51.5% of eyes failed by the end of 10 years, with most failures occurring within the first year (40%). Although CYC provides a useful method to lower IOP significantly, this study suggests that its success in controlling IOP is tempered by its failure rate and risk of complications, including visual loss, phthisis, and loss of light perception.

Adolescent↗

Imaging in glaucoma.

Structural assessment using the imaging technologies discussed herein provides reproducible quantitative measurements of posterior segment ocular structures. These measurements have been found to provide useful data for glaucoma detection in various regions of the posterior segment. Further studies are needed to evaluate the utility of these technologies for pre-perimetric glaucoma detection and for monitoring glaucoma progression over an extended period.

Diagnostic Imaging↗

Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

PURPOSE: The measurement reproducibility of the third generation of commercial optical coherence tomography, OCT-3 (StratusOCT, software ver. A2, Carl Zeiss Meditec Inc., Dublin, CA) was investigated. The nerve fiber layer (NFL) thickness, macula thickness map, and optic nerve head (ONH) parameters in normal eyes were studied. METHODS: Ten normal subjects were imaged six times (three before and three after dilation) per day, and the series was repeated on three different days. The order of the scans before pupil dilation was randomized in each of the 3 days of scanning. After pupil dilation, the scans were also randomized in each of the 3 days of scanning. Each series was performed separately for standard-density (128 A-scans per macular and ONH image and 256 A-scans per NFL image) and high-density (512 A-scans per image for all three scan types) scanning. RESULTS: The mean macular thickness was 235 +/- 9.8 micro m. A-scan density (or image acquisition speed) had a statistically significant effect (P < 0.05) on the reproducibility of the mean macular thickness, macular volume, and a few sectors of the macular map. No significant dilation effect was found for any of the macular parameters. The best intraclass correlation coefficient (ICC; 94%) for macular scans was found for dilated high-density scanning, with an intervisit SD of 2.4 micro m and an intravisit SD of 2.2 micro m. The mean NFL thickness for standard scanning was 98 +/- 9 micro m. NFL reproducibility showed mixed results and had interactions between scan density and dilation for some parameters. For most of the NFL parameters, reproducibility was better with dilated standard-density scanning. The mean NFL thickness ICC for dilated standard scanning was 79%, with an intervisit SD of 2.5 micro m and an intravisit SD of 1.6 micro m. For the ONH analysis, the reproducibility was better for dilated standard-density scanning for almost all the parameters, except for disc area, horizontal integrated rim volume, and vertical integrated rim area, which were better before dilation. The best reproducibility was found for cup-to-disc ratio (ICC = 97%, with intervisit SD of 0.04 micro m and intravisit SD of 0.02 micro m). CONCLUSIONS: StratusOCT demonstrated reproducible measurements of NFL thickness, macular thickness, and optic nerve head parameters. The best reproducibility was found for dilated standard scanning for NFL and ONH parameters and for dilated high-density scanning for macular parameters.

Adult↗

Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy.

PURPOSE: To evaluate the relationship between optic nerve head (ONH) measurements generated by optical coherence tomography (OCT; versions 2 and 3) and confocal scanning laser ophthalmoscopy (CSLO) and to compare the association between OCT and CSLO ONH measurements with glaucoma disease status, as determined by clinical evaluation and perimetry. DESIGN: Cross-sectional study. METHODS: In a prospective study in the glaucoma service of an academic department of ophthalmology, 159 eyes (97 subjects) and 77 eyes (44 subjects) were recruited in two separate periods. All subjects were scanned with a CSLO device. Subjects tested within the first period of recruitment were scanned with OCT version 2 and in the second period with OCT version 3. The main outcome measure was the correlation between automatic and manually defined OCT ONH measurements and the correlation of CSLO and OCT ONH measurements between devices and with glaucoma disease status. RESULTS: A high correlation was found between ONH measurements obtained by the automatic determination of ONH margin and those obtained by manual tracing of the disk margin (r =.93 to.98). Optical coherence tomography and CSLO ONH measurements were highly correlated. Optical coherence tomography-measured mean disk area was significantly larger than that measured by CSLO, as were all other disk size-related parameters. The areas under the receiver operator characteristic (AROC) curves for the associations between CSLO and OCT ONH measurements and clinical diagnosis were found to be similar and in the range of 0.47 to 0.79 for both devices. CONCLUSIONS: Automated OCT ONH measurements correlate highly with those obtained by manual tracing of disk margin. Optical coherence tomography and CSLO ONH analyses are highly correlated and have similar associations with glaucoma disease status.

Cross-Sectional Studies↗