PubMed Health⌕ Search

Biomedical subjects

Garry E Gold

Publications and source records attributed to Garry E Gold.

At least 19 recordsLinked to original sources

Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession--initial experience.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. In this study, iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) balanced steady-state free precession (bSSFP), fat-suppressed bSSFP, and fat-suppressed spoiled gradient-echo (GRE) sequences for 3.0-T magnetic resonance (MR) imaging of articular knee cartilage were prospectively compared in five healthy volunteers. Cartilage and fluid signal-to-noise ratio (SNR), cartilage-fluid contrast-to-noise ratio (CNR), SNR efficiency, CNR efficiency, image quality, and fat suppression were compared. Fat-suppressed bSSFP and IDEAL bSSFP had higher SNR efficiency of cartilage (P < .01) than did GRE. IDEAL bSSFP had higher cartilage-fluid CNR efficiency than did fat-suppressed bSSFP or GRE (P < .01). Fat-suppressed bSSFP and IDEAL bSSFP had higher image quality than did GRE (P < .01). GRE and IDEAL bSSFP had significantly better fat-water separation or fat saturation than did fat-suppressed bSSFP (P < .05). IDEAL bSSFP is a promising method for imaging articular knee cartilage.

Adult↗

MRI of articular cartilage in OA: novel pulse sequences and compositional/functional markers.

Osteoarthritis (OA) is a leading cause of disability worldwide. Magnetic resonance imaging (MRI), with its unique ability to image and characterize soft tissue non-invasively, has proven valuable in assessing cartilage in OA. The development of new, fast imaging methods with high contrast show promise to improve the magnetic resonance (MR) evaluation of this disease. In addition to morphologic MRI methods, MRI contrast mechanisms under development may reveal detailed information about the physiology of cartilage. It is anticipated that these and other MRI techniques will play an increasingly important role in assessing the success or failure of therapies for OA. On December 5 and 6, 2002, OMERACT (Outcome Measures in Rheumatology Clinical Trials) and OARSI (Osteoarthritis Research Society International) held a workshop in Bethesda, MD aiming at providing a state-of-the-art review of imaging outcome measures for OA of the knee to help guide scientists and pharmaceutical companies in the use of MRI in multi-site studies of OA. Applications of MRI were initially reviewed by a multidisciplinary, international panel of expert scientists and physicians from academia, the pharmaceutical industry and regulatory agencies. The findings of the panel were then presented to a wider group of participants for open discussion. The following report summarizes the results of these discussions with respect to novel MRI pulse sequences for evaluating articular cartilage of the knee in OA and notes any additional advances that have been made since.

Cartilage, Articular↗

Comparison of quantitative cartilage measurements acquired on two 3.0T MRI systems from different manufacturers.

PURPOSE: To investigate the comparability of two osteoarthritis (OA) surrogate endpoints--average cartilage thickness and cartilage volume--acquired from healthy volunteers on two 3.0T magnetic resonance imaging (MRI) systems from different manufacturers. MATERIALS AND METHODS: Ten knees of five healthy volunteers were scanned on a 3.0T General Electric (GE) and a 3.0T Philips scanner using a fast three-dimensional fat-suppressed spoiled gradient (SPGR) imaging sequence. The acquisition parameters were optimized beforehand and were kept as comparable as possible on both scanners. For quantitative analysis, the average cartilage thickness and volume of the load-bearing regions of the femoral condyles were compared. Data were analyzed using a univariate repeated-measures analysis of variance (ANOVA) to examine the effects of position, condyle, and imaging system on the measurements. RESULTS: The average cartilage thickness and volume of the load-bearing regions of the femoral condyles did not differ between the two different 3.0T MRI systems (P > 0.05). There was no significant effect of position or condyle on the average cartilage thickness measurements (P > 0.05; range = 0.41-0.93) or cartilage volume (P > 0.05; range = 0.14-0.87). CONCLUSION: Two OA surrogate endpoints--average cartilage thickness and cartilage volume--acquired on two 3.0T MRI systems from different manufacturers are comparable.

Adult↗

T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation.

PURPOSE: To compare the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) method with fat-saturated T1-weighted (T1W) and T2W fast spin-echo (FSE) and short-TI inversion recovery (STIR) imaging of the brachial plexus and cervical spine. MATERIALS AND METHODS: Images acquired at 1.5T in five volunteers using fat-saturated T1W and T2W FSE imaging and STIR were compared with T1W and T2W IDEAL-FSE images. Examples of T1W and T2W IDEAL-FSE images acquired in patients are also shown. RESULTS: T1W and T2W IDEAL-FSE demonstrated superior fat suppression (P<0.05) and image quality (P<0.05), compared to T1W and T2W fat-saturated FSE, respectively. SNR performance of T1W-IDEAL-FSE was similar to T1W FSE in the spinal cord (P=0.250) and paraspinous muscles (P=0.78), while T2W IDEAL-FSE had superior SNR in muscle (P=0.02) and CSF (P=0.02), and marginally higher cord SNR (P=0.09). Compared to STIR, T2W IDEAL-FSE demonstrated superior image quality (P<0.05), comparable fat suppression (excellent, P=1.0), and higher SNR performance (P<0.001). CONCLUSION: IDEAL-FSE is a promising method for T1W and T2W imaging of the brachial plexus and cervical spine.

Adipose Tissue↗

Fluid-attenuated inversion-recovery SSFP imaging.

PURPOSE: To describe and evaluate a fast, fluid-suppressed 2D multislice steady-state free precession (SSFP) neuroimaging sequence. MATERIALS AND METHODS: We developed a fast fluid-attenuated inversion-recovery SSFP sequence for use in neuroimaging. The inversion time (TI) was optimized to yield good cerebrospinal fluid (CSF) suppression while conserving white matter (WM)/lesion contrast across a broad range of flip angles. Multiple SSFP acquisitions were combined using the sum-of-squares (SOS) method to maximize SNR efficiency while minimizing SSFP banding artifacts. We compared our fluid-attenuated inversion-recovery (FLAIR) SSFP sequence with FLAIR fast spin-echo (FSE) in both normal subjects and a volunteer with multiple sclerosis. SNR measurements were performed to ascertain the SNR efficiency of each sequence. RESULTS: Our FLAIR SSFP sequence demonstrated excellent CSF suppression and good gray matter (GM)/WM contrast. Coverage of the entire brain (5-mm slices, 24-cm FOV, 256 x 192 matrix) was achieved with FLAIR SSFP in less than half the scan time of a corresponding FLAIR FSE sequence with similar SNR, yielding improvements of more than 50% in SNR efficiency. Axial scans of a volunteer with multiple sclerosis show clearly visible plaques and very good visualization of brain parenchyma. CONCLUSION: We have demonstrated the feasibility of a very fast fluid-suppressed neuroimaging technique using SSFP.

Algorithms↗

Linear combination filtering for T2-selective imaging of the knee.

Recently a novel T2 selective imaging method based on linear combination (LC) filtering was developed. By linearly combining images acquired with different echo times LC filtering is able to generate images showing only tissues with a preselected range of T2 relaxation times. In this study the use of LC filtering in knee imaging was investigated. Three LC filters were designed: a short LC filter for imaging the knee meniscus, a medium LC filter for articular cartilage, and a long LC filter for synovial fluid. To verify the filter designs, eight phantoms with different T2 relaxation times were imaged. In addition, in vivo images were acquired from four asymptomatic volunteers and a subject with cartilage damage. T2 maps were also generated using the same source images. Signal-to-noise ratio (SNR) measurements were made of the meniscus, cartilage, and fluid regions on the three LC filtered images. The highest SNR was seen in the target tissue on each of the LC filtered images. LC filtering is a new method that can selectively image knee tissues based on their T2.

Cartilage, Articular↗

Designing long-T2 suppression pulses for ultrashort echo time imaging.

Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 values. In this article, new long-T2 suppression RF pulses that improve the contrast of short-T2 species are introduced. These pulses are improvements over previous long-T2 suppression pulses that suffered from poor off-resonance characteristics or T1 sensitivity. Short-T2 tissue contrast can also be improved by suppressing fat in some applications. Dual-band long-T2 suppression pulses that additionally suppress fat are also introduced. Simulations, along with phantom and in vivo experiments using 2D and 3D UTE imaging, demonstrate the feasibility, improved contrast, and improved sensitivity of these new long-T2 suppression pulses. The resulting images show predominantly short-T2 species, while most long-T2 species are suppressed.

Adipose Tissue↗

Prepolarized magnetic resonance imaging around metal orthopedic implants.

A prepolarized MRI (PMRI) scanner was used to image near metal implants in agar gel phantoms and in in vivo human wrists. Comparison images were made on 1.5- and 0.5-T conventional whole-body systems. The PMRI experiments were performed in a smaller bore system tailored to extremity imaging with a prepolarization magnetic field of 0.4 T and a readout magnetic field of 27-54 mT (1.1-2.2 MHz). Scan parameters were chosen with equal readout gradient strength over a given field of view and matrix size to allow unbiased evaluation of the benefits of lower readout frequency. Results exhibit substantial reduction in metal susceptibility artifacts under PMRI versus conventional scanners. A new artifact quantification technique is also presented, and phantom results confirm that susceptibility artifacts improve as expected with decreasing readout magnetic field using PMRI. This proof-of-concept study demonstrates that prepolarized techniques have the potential to provide diagnostic cross-sectional images for postoperative evaluation of patients with metal implants.

Adult↗

Software tools for interactive instruction in radiologic anatomy.

RATIONALE AND OBJECTIVES: To promote active learning in an introductory Radiologic Anatomy course through the use of computer-based exercises. MATERIALS AND METHODS: DICOM datasets from our hospital PACS system were transferred to a networked cluster of desktop computers in a medical school classroom. Medical students in the Radiologic Anatomy course were divided into four small groups and assigned to work on a clinical case for 45 minutes. The groups used iPACS viewer software, a free DICOM viewer, to view images and annotate anatomic structures. The classroom instructor monitored and displayed each group's work sequentially on the master screen by running SynchronEyes, a software tool for controlling PC desktops remotely. RESULTS: Students were able to execute the assigned tasks using the iPACS software with minimal oversight or instruction. Course instructors displayed each group's work on the main display screen of the classroom as the students presented the rationale for their decisions. The interactive component of the course received high ratings from the students and overall course ratings were higher than in prior years when the course was given solely in lecture format. CONCLUSIONS: DICOM viewing software is an excellent tool for enabling students to learn radiologic anatomy from real-life clinical datasets. Interactive exercises performed in groups can be powerful tools for stimulating students to learn radiologic anatomy.

Anatomy↗

Advanced magnetic resonance imaging of articular cartilage.

MRI is one of the most accurate imaging methods available to diagnose disorders of articular cartilage. Conventional two-dimensional and three-dimensional approaches show changes in cartilage morphology. Newer and substantially faster three-dimensional imaging methods show great promise to improve MRI of cartilage. These methods may allow acquisition of fluid-sensitive isotropic data that can be reformatted into arbitrary planes for improved detection and visualization of pathology. Unique MRI contrast mechanisms also allow clinicians to probe cartilage physiology and detect early changes in cartilage macromolecules.

Cartilage, Articular↗

Articular cartilage of the knee: evaluation with fluctuating equilibrium MR imaging--initial experience in healthy volunteers.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study, whose purpose was to prospectively compare three magnetic resonance (MR) imaging techniques-fluctuating equilibrium, three-dimensional (3D) spoiled gradient-recalled acquisition in the steady state (SPGR), and two-dimensional (2D) fast spin echo (SE)-for evaluating articular cartilage in the knee. The study cohort consisted of 10 healthy volunteers (four men, six women; age range, 26-42 years). Cartilage signal-to-noise ratio (SNR), SNR efficiency, cartilage-fluid contrast-to-noise ratio (CNR), CNR efficiency, image quality, cartilage visibility, and fat suppression were compared. Cartilage volume was compared for the fluctuating equilibrium and 3D SPGR techniques. Compared with 3D SPGR and 2D fast SE, fluctuating equilibrium yielded the highest cartilage SNR efficiency and cartilage-fluid CNR efficiency (P < .01 for both). Image quality was similar with all sequences. Fluctuating equilibrium imaging yielded higher cartilage visibility than did 2D fast SE imaging (P <. 01) but worse fat suppression than did 3D SPGR and 2D fast SE imaging (P < .04). Cartilage volume measurements with fluctuating equilibrium and 3D SPGR were similar. Fluctuating equilibrium MR imaging is a promising method for evaluating articular cartilage in the knee.

Adult↗

Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fast spin-echo imaging of the ankle: initial clinical experience.

OBJECTIVE: Reliable, uniform fat suppression is important. Multiple approaches currently exist, many of which suffer from either suboptimal signal-to-noise ratio (SNR), or the inability to obtain consistent fat suppression around the ankle joint. Our purpose was to test iterative decomposition of water and fat with echo asymmetry and the least-squares estimation (IDEAL) method in combination with fast spin-echo imaging, which is able to achieve reliable high SNR images with uniform fat-water separation. SUBJECTS AND METHODS: We compared IDEAL fast spin-echo with conventional fat-suppressed fast spin-echo imaging in 33 ankles in 32 patients. Quantitative measurements of SNR and contrast-to-noise ratio efficiency were made, and qualitative diagnostic image quality and fat-suppression scores were determined. RESULTS: We found that the SNR efficiency for both cartilage and fluid was similar for both techniques, and fluid/cartilage contrast-to-noise ratio efficiency was higher with IDEAL fast spin-echo imaging. Fat suppression and diagnostic quality scores using the IDEAL method were superior (p < 0.01) to fat-suppressed fast spin-echo imaging. CONCLUSION: IDEAL fast spin-echo imaging is a promising technique for MRI of the ankle.

Adipose Tissue↗

Driven equilibrium magnetic resonance imaging of articular cartilage: initial clinical experience.

PURPOSE: To evaluate three-dimensional driven equilibrium Fourier transform (3D-DEFT) for image quality and detection of articular cartilage lesions in the knee. MATERIALS AND METHODS: We imaged 104 consecutive patients with knee pain with 3D-DEFT and proton density (PD-FSE) and T2-weighted (T2-FSE) fast spin echo. Twenty-four went on to arthroscopy. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) efficiency were measured. Subjective image quality, fat suppression, and cartilage thickness visibility were assessed. Cartilage lesions on 3D-DEFT and T2-FSE were compared with findings outlined in operative reports. RESULTS: SNR efficiency was higher for 3D-DEFT and PD-FSE than for T2-FSE (P < 0.02). 3D-DEFT and PD-FSE showed superior cartilage thickness visibility compared with T2-FSE (P < 0.02). T2-FSE showed better fat suppression and fewer image artifacts than 3D-DEFT (P < 0.04). 3D-DEFT had similar sensitivity and similar specificity for cartilage lesions compared with PD-FSE and T2-FSE. CONCLUSION: 3D-DEFT provides excellent synovial fluid-to-cartilage contrast while preserving signal from cartilage, giving this method a high cartilage SNR. 3D-DEFT shows the full cartilage thickness better than T2-FSE. T2-FSE had superior fat saturation and fewer artifacts than 3D-DEFT. Overall, 3D-DEFT requires further technical development, but is a promising method for imaging articular cartilage.

Arthroscopy↗

Echo time optimization for linear combination myelin imaging.

A 3-echo linear combination myelin imaging method is presented. The echo times and weights are chosen such that the signal-to-noise ratio (SNR) of myelin-water is maximized, and signals from other white matter components are sufficiently suppressed. Interfering tissue water and cerebrospinal fluid (CSF) signals are much stronger than myelin due to their longer T2 and abundance. By carefully optimizing the echo times a 50-fold tissue water suppression is achieved along with a 10-fold CSF suppression. For comparison 4, 5, and 32 echo filters are also designed using the same method. The SNR efficiency of these filters is very similar. The 3-echo filter design was validated by phantom scans. In addition, multislice in vivo myelin images were acquired from both a healthy volunteer and a multiple sclerosis patient. Total scan time was 5 min. A uniform T2 filter is also designed to pass all white matter species with uniform gain. The myelin-water fraction of the in vivo 3-echo data set is then measured by dividing the myelin image by the uniformly filtered image. Obtained myelin-water fractions compare well with previous work.

Algorithms↗

Reduction of blurring in view angle tilting MRI.

Magnetic resonance imaging (MRI) in the presence of metallic objects suffers from slice-selection errors and in-plane distortions. View angle tilting (VAT) corrects for in-plane distortions by adding a gradient on the slice-select axis during readout, but can suffer from image blurring. This work demonstrates that the major source of blurring is a slice profile modulation of the data, and proposes several solutions to prevent such blurring. Multiple high-bandwidth readouts are demonstrated to reduce the blurring while improving the signal-to-noise ratio (SNR) over a single high-bandwidth readout.

Artifacts↗

Automatic tuning of flexible interventional RF receiver coils.

Microcontroller-based circuitry was built and tested for automatically tuning flexible RF receiver coils at the touch of a button. This circuitry is robust to 10% changes in probe center frequency, is in line with the scanner, and requires less than 1 s to tune a simple probe. Images were acquired using this circuitry with a varactor-tunable 1-inch flexible probe in a phantom and in an in vitro porcine knee model. The phantom experiments support the use of automatic tuning by demonstrating 30% signal-to-noise ratio (SNR) losses for 5% changes in coil center frequency, in agreement with theoretical calculations. Comparisons between patellofemoral cartilage images obtained using a 3-inch surface coil and the surgically-implanted 1-inch flexible coil reveal a worst-case local SNR advantage of a factor of 4 for the smaller coil. This work confirms that surgically implanted coils can greatly improve resolution in small-field-of-view (FOV) applications, and demonstrates the importance and feasibility of automatically tuning such probes.

Animals↗

Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2pi/3, with the middle echo centered at pi/2+pik (k=any integer), i.e., (-pi/6+pik, pi/2+pik, 7pi/6+pik). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.

Adipose Tissue↗