PubMed Health⌕ Search

Biomedical subjects

Gary A Griess

Publications and source records attributed to Gary A Griess.

3 recordsLinked to original sources

Matrix conditioning for lengthened capillary DNA sequencing.

Capillary electrophoresis (CE) is currently the preferred format for both DNA sequencing and small DNA fragment analysis. The present study provides a simple revision of the procedure used for CE of DNA with a commercial DNA sequencing apparatus from Applied Biosystems. The revision is electrophoretic conditioning of the sieving matrix (typically POP-6) before sample injection. The effects of this preconditioning are revealed during subsequent analyses performed without replenishing the sieving matrix. The primary effect of preconditioning is to increase peak separations during a subsequent CE. The preconditioning has the following characteristics: (i) The effect on peak separation progressively increases as the preconditioning time increases to at least 6 h. (ii) The effect on peak separation scales approximately as the product of the preconditioning time and the magnitude of the electrical field (162 - 320 V/cm) during preconditioning. (iii) The preconditioning persists for more than 72 h at zero field. Preconditioning of the matrix substantially improves resolution of fragment analysis in the range of 700-2000 nucleotides. For DNA sequencing, the primary impact of preconditioning is, thus far, extension of the range of low-quality base calls at the end of sequence reading. Matrix preconditioning is a new factor to consider when interpreting data obtained by CE in polymer solutions. The mechanism of preconditioning is not yet known.

DNA↗

Temperature-dependence of preconditioning for lengthened capillary DNA sequencing.

A previous study shows that electrophoretic preconditioning of a commercial polymer solution increases the spacing and resolution of DNA fragments fractionated in this solution by CE at 50 degrees C (Griess, G. A. et al., Electrophoresis 2005, 26, 102). The present study shows that this preconditioning effect on peak spacing progressively increases when the temperature of preconditioning increases to 70 degrees C, though fractionation is still performed at 50 degrees C. An increase in peak sharpness accompanies the increase in peak separation for DNA fragments longer than 200 bases. Changing the preconditioning temperature from 50 to 70 degrees C optimally improves resolution of fragment analysis in the range of 600-2000 nucleotides. When DNA sequencing is performed with automated base calling and 70 degrees C preconditioning at 319 V/cm (47 cm long capillary, Applied Biosystems 310 apparatus), the range of high-quality base calls is increased by 25% to 750; the range of low-quality base calls is increased by about 100% to 1200 in comparison to DNA sequencing without preconditioning.

DNA↗

Cyclic capillary electrophoresis.

A strategy is described here for increasing both the resolution and the flexibility of capillary electrophoresis performed in a sieving medium of ungelled polymer. This strategy is based on analysis and, sometimes, re-analysis that is done in several stages of constant-field electrophoresis. Enhancement-stages are between the analysis-stages. An enhancement-stage (i) increases the separation between peaks, while (ii) moving DNA molecules in the reverse direction. An enhancement-stage is based on an electrophoretic ratchet generated by a pulsed electrical field that can be zero-integrated. The ratchet-generating pulses are longer than the field pulses that have previously been used to improve the resolution of DNA molecules. No limit has been found to the resolution enhancement achievable. Apparently, diffusion-induced peak broadening is inhibited and, in some cases, may be reversed by the ratchet. The enhancement-stages are critically dependent on the electrical field-dependence of a plot of electrophoretic mobility as a function of DNA length. To generate the pulsed electrical field, a computer-controlled system with a time resolution of 30 microseconds has been developed. Programming is flexible enough to embed other pulses within ratchet-generating pulses. These other pulses can be either the previously used, shorter field-inversion pulses or high-frequency periodic oscillations previously found to sharpen peaks.

Computers↗