PubMed Health⌕ Search

Biomedical subjects

Gary Barrett

Publications and source records attributed to Gary Barrett.

4 recordsLinked to original sources

A rapid highly-sensitive endotoxin detection system.

This paper presents a rapid, highly-sensitive, and low-cost method of endotoxin quantification based on the use of stress-responsive magnetoelastic sensors, that monitor the gel formation (viscosity change) of the Limulus Amoebocyte Lysate (LAL) assay in response to endotoxin. Ribbon-like magnetoelastic sensors, 12.7 mm x 6 mm x 28 microm, were immersed in a LAL assay after mixing with test samples of variable endotoxin concentration, and the decrease in resonance amplitude of the sensor was recorded as a function of time. Experimental results show excellent correlation between endotoxin concentration and the maximum clot rate, determined by taking the minimum point of the first derivative of the amplitude-time curve, as well as the clotting-time, defined as the time that corresponds to the maximum clot rate. Using a LAL gel-clot assay with a sensitivity of 0.06 EU/ml (EU: endotoxin unit), the magnetoelastic sensor based technology can detect the presence of endotoxin at 0.0105 EU/ml in test requiring approximately 20 min. Unlike optical methods used for determining endotoxin concentration, the color of the test solution does not impact the magnetoelastic sensor measurement. Due to the small size of the sensor reader electronics and low cost, the magnetoelastic sensor based endotoxin detection system is ideally suited for wide-spread use in endotoxin screening for sepsis prevention.

Biosensing Techniques↗

Monitoring blood coagulation with magnetoelastic sensors.

The determination of blood coagulation time is an essential part of monitoring therapeutic anticoagulants. Standard methodologies for the measurement of blood clotting time require dedicated personnel and involve blood sampling procedures. A new method based on magnetoelastic sensors has been employed for the monitoring of blood coagulation. The ribbon-like magnetoelastic sensor oscillates at a fundamental frequency, which shifts linearly in response to applied mass loads or a fixed mass load of changing elasticity. The magnetoelastic sensors emit magnetic flux, which can be detected by a remotely located pick-up coil, so that no direct physical connections are required. During blood coagulation, the viscosity of blood changes due to the formation of a soft fibrin clot. In turn, this change in viscosity shifts the characteristic resonance frequency of the magnetoelastic sensor enabling real-time continuous monitoring of this biological event. By monitoring the signal output as a function of time, a distinct blood clotting profile can be seen. The relatively low cost of the magnetoelastic ribbons enables their use as disposable sensors. This, along with the reduced volume of blood required, make the magnetoelastic sensors well suited for at-home and point-of-care testing devices.

Animals↗