PubMed Health⌕ Search

Biomedical subjects

Gary L Bowlin

Publications and source records attributed to Gary L Bowlin.

15 recordsLinked to original sources

Electrospun fibrinogen: feasibility as a tissue engineering scaffold in a rat cell culture model.

Fibrinogen has a well-established tissue engineering track record because of its ability to induce improved cellular interaction and scaffold remodeling compared to synthetic scaffolds. While the feasibility of electrospinning fibrinogen scaffolds of submicron diameter fibers and their mechanical properties have been demonstrated, in vitro cellular interaction has not yet been evaluated. The goal of this study was to demonstrate, based on cellular interaction and scaffold remodeling, that electrospun fibrinogen can be used successfully as a tissue engineering scaffold. Electrospun fibrinogen scaffolds were disinfected, seeded with neonatal rat cardiac fibroblasts, and cultured for 2, 7, and 14 days. Cultures were treated to regulate scaffold degradation by either supplementing serum-containing media with aprotinin or crosslinking the scaffolds with glutaraldehyde vapor. Biocompatibility was assessed through a WST-1 cell proliferation assay. Postculture scaffolds were evaluated by scanning electron microscopy and histology. Cell culture demonstrated that fibroblasts readily migrate into and remodel electrospun fibrinogen scaffolds with deposition of native collagen. Supplementation of culture media with different concentrations of aprotinin-modulated scaffold degradation in a predictable fashion, but glutaraldehyde vapor fixation was less reliable. Based on the observed cellular interactions, there is tremendous potential for electrospun fibrinogen as a tissue engineering scaffold.

Animals↗

Modulation of anisotropy in electrospun tissue-engineering scaffolds: Analysis of fiber alignment by the fast Fourier transform.

We describe the use of the fast Fourier transform (FFT) in the measurement of anisotropy in electrospun scaffolds of gelatin as a function of the starting conditions. In electrospinning, fiber alignment and overall scaffold anisotropy can be manipulated by controlling the motion of the collecting mandrel with respect to the source electrospinning solution. By using FFT to assign relative alignment values to an electrospun matrix it is possible to systematically evaluate how different processing variables impact the structure and material properties of a scaffold. Gelatin was suspended at varying concentrations (80, 100, 130, 150 mg/ml) and electrospun from 2,2,2 trifluoroethanol onto rotating mandrels (200-7000 RPM). At each starting concentration, fiber diameter remained constant over a wide range of mandrel RPM. Scaffold anisotropy developed as a function of fiber diameter and mandrel RPM. The induction of varying degrees of anisotropy imparted distinctive material properties to the electrospun scaffolds. The FFT is a rapid method for evaluating fiber alignment in tissue-engineering materials.

Anisotropy↗

Mechanical properties of electrospun fibrinogen structures.

Fibrin and fibrinogen have a well-established track record in tissue engineering due to their innate ability to induce improved cellular interaction and subsequent scaffold remodeling compared to synthetic scaffolds. Use of fibrinogen as a primary scaffold component, however, has been limited by traditional processing techniques that render scaffolds with insufficient mechanical properties. The goal of this study was to demonstrate, based on mechanical properties, that electrospun fibrinogen overcomes these limitations and can be successful as a tissue engineering scaffold or wound dressing. Electrospun fibrinogen scaffolds were characterized for fiber diameter and pore area and subsequently tested for uniaxial mechanical properties while dry and hydrated. In addition, uniaxial mechanical testing was conducted on scaffolds treated to regulate scaffold degradation in serum-containing media by supplementing the media with aprotinin or cross-linking the scaffolds with glutaraldehyde vapor. A linear relationship between electrospinning solution concentration and measured fiber diameter was seen; fiber diameters ranged from 120 to 610 nm over electrospinning concentrations of 80 to 140 mg/ml fibrinogen, respectively. Pore areas ranged from 1.3 microm(2) to 13 microm(2) over the same fibrinogen concentrations. Aprotinin in the culture media inhibited scaffold degradation in a predictable fashion, but glutaraldehyde vapor fixation produced less reliable results as evidenced by mechanical property testing. In conclusion, the mechanical characteristics of electrospun fibrinogen strongly support its potential use as a tissue engineering scaffold or wound dressing.

Animals↗

Electrospinning polydioxanone for biomedical applications.

Polydioxanone (PDS) is a colorless, crystalline, bioabsorbable polymer that was first developed specifically for wound closure sutures. The compatibility, degradation rate, and mechanical properties (including shape memory) of PDS are of interest when considering the design of tissue engineering scaffolds. This research presents the electrospinning of PDS to fabricate unique nanofibrous structures for a variety of biomedical applications. Electrospinning is a polymer processing technique that utilizes an electric field to form fibers from a polymer solution or melt and allows the fabrication of nanofibrous non-woven structures. Results demonstrate the ability to control the fiber diameter of PDS as a function of solution concentrations and the fiber orientation with our prototype electrospinning apparatus. The results also show dependence between the fiber orientation and the elastic modulus, peak stress, and strain to failure of PDS in a uniaxial model.

Biocompatible Materials↗

Utilizing acid pretreatment and electrospinning to improve biocompatibility of poly(glycolic acid) for tissue engineering.

Poly(glycolic acid) (PGA) has a long history as a bioresorbable polymer. Its biocompatibility is widely accepted, yet PGA is often rejected as a soft-tissue scaffold because of fibrous encapsulation. The goal of this study was to improve the soft-tissue biocompatibility of PGA by producing scaffolds composed of small-diameter fibers through electrospinning and subjecting these scaffolds to a concentrated hydrochloric acid (HCL) pretreatment. The theory is that small-diameter fibers will elicit a reduced immune response and HCl treatment will improve cellular interactions. Scaffolds were characterized in terms of fiber diameter and pore area via image-analysis software. Biocompatibility was assessed through a WST-1 cell-proliferation assay (in vitro) with the use of rat cardiac fibroblasts and rat intramuscular implantations (in vivo). Fibers produced ranged in diameter from 0.22 to 0.88 microm with pore areas from 1.84 to 13.22 microm(2). The untreated scaffold composed of 0.88-microm fibers was encapsulated in vivo and supported the lowest rates of cell proliferation. On the contrary, the acid pretreated scaffold with 0.22-microm fibers was incorporated into the surrounding tissue and exhibited proliferation rates that exceeded the control populations on tissue-culture plastic. In conclusion, this study has shown the ability to improve the biocompatibility of PGA through acid pretreatment of scaffolds comprised of submicron fiber diameters.

Animals↗

Endothelial cell seeding of polymeric vascular grafts.

Pioneers in the field of small diameter graft development sought to promote graft endothelialization and, thereby, increase patency by transplanting a varying degree of autologous endothelial cells onto vascular grafts prior to implantation. This process has become known as endothelial cell seeding. The underlying hypothesis is quite simple; that is, by promoting the establishment of the patient's own endothelial cells on the blood contacting surface of a vascular prosthesis, a "normal" endothelial cell lining and associated basement membrane, together known as the neointima, will form on the graft and counteract the rheologic, physiologic, and biomaterial forces working synergistically to promote graft failure. After 30 years of research in this area, this simple hypothesis has proven to be deceptively naive. The purpose of this review is to summarize the historic context and current base of knowledge regarding many of the technical issues relevant to the endothelial cell seeding process. Special attention is given to electrostatic endothelial cell seeding, the latest research methodology designed specifically to accelerate endothelial cell adhesion and morphological maturation onto expanded poly(tetrafluoroethylene) (e-PTFE) small diameter vascular grafts.

Blood Vessel Prosthesis↗

Electrospinning collagen and elastin: preliminary vascular tissue engineering.

Significant challenges must be overcome before the true benefit and economic impact of vascular tissue engineering can be fully realized. Toward that end, we have pioneered the electrospinning of micro- and nano-fibrous scaffoldings from the natural polymers collagen and elastin and applied these to development of biomimicking vascular tissue engineered constructs. The vascular wall composition and structure is highly intricate and imparts unique biomechanical properties that challenge the development of a living tissue engineered vascular replacement that can withstand the high pressure and pulsatile environment of the bloodstream. The potential of the novel scaffold presented here for the development of a viable vascular prosthetic meets these stringent requirements in that it can replicate the complex architecture of the blood vessel wall. This replication potential creates an "ideal" environment for subsequent in vitro development of a vascular replacement. The research presented herein provides preliminary data toward the development of electrospun collagen and elastin tissue engineering scaffolds for the development of a three layer vascular construct.

Blood Vessel Prosthesis↗

Electrospinning of poly(ethylene-co-vinyl alcohol) fibers.

Solutions of poly(ethylene-co-vinyl alcohol) or EVOH, ranging in composition from 56 to 71 wt% vinyl alcohol, can be readily electrospun at room temperature from solutions in 70% 2-propanol/water (rubbing alcohol). The solutions are prepared at 80 degrees C and allowed to cool to room temperature. Interestingly, the solutions are not stable at room temperature and eventually the polymer precipitates after several hours. However, prior to precipitation, electrospinning is extensive and rapid, allowing coverage of fibers on various substrates, including a grounded metal plate, dielectrics interposed between the charged jet and the metal ground, and on the human body. Fiber diameters of ca. 0.2-8.0 microm were obtained depending upon the solution concentration, an attractive range for tissue engineering, wound healing, and related applications. Electrospun EVOH mats have been shown to support the culturing of smooth muscle cells and fibroblasts.

2-Propanol↗

Release of tetracycline hydrochloride from electrospun poly(ethylene-co-vinylacetate), poly(lactic acid), and a blend.

Electrospun fiber mats are explored as drug delivery vehicles using tetracycline hydrochloride as a model drug. The mats were made either from poly(lactic acid) (PLA), poly(ethylene-co-vinyl acetate) (PEVA), or from a 50:50 blend of the two. The fibers were electrospun from chloroform solutions containing a small amount of methanol to solubilize the drug. The release of the tetracycline hydrochloride from these new drug delivery systems was followed by UV-VIS spectroscopy. Release profiles from the electrospun mats were compared to a commercially available drug delivery system, Actisite (Alza Corporation, Palo Alto, CA), as well as to cast films of the various formulations.

Anti-Bacterial Agents↗

Evaluation of electrostatically endothelial cell seeded expanded polytetrafluoroethylene grafts in a canine femoral artery model.

PURPOSE: The purpose of this study was to evaluate the extent (luminal coverage) of the endothelial cell (EC) lining/neointimal development and the thromboresistance of electrostatically EC seeded small diameter e-PTFE vascular grafts. METHODS: This evaluation consisted of harvesting autologous, canine jugular vein ECs, electrostatically EC seeding the e-PTFE grafts (4 mm GORE-TEX, Length = 6 cm), implanting the grafts in a canine femoral artery model for six weeks, and excising the graft for histological and scanning electron microscopy evaluations. RESULTS: The results of the histological evaluation (mid-graft region only) indicated that the electrostatic EC seeding significantly affected neointimal development (p < 0.01) and the degree of thrombus formation (p < 0.001) within the EC seeded grafts versus the untreated control grafts. Scanning electron microscopy examination demonstrated a mature, confluent endothelium with a "cobblestone" appearance on the EC seeded graft luminal surface. The control grafts demonstrated an equal distribution of SMCs through the graft wall while the electrostatically EC seeded graft sections exhibited an uneven SMC cellular distribution which was skewed toward the graft luminal surface. CONCLUSIONS: The presence of electrostatic EC seeding significantly (p < 0.01) enhanced the development of a neointima and reduced the incidence of thrombosis in e-PTFE grafts implanted in a canine femoral artery model. Results of the mid-graft SMC migration measurements indicate that the electrostatic EC seeding had a significant (p < 0.001) impact on the acute healing of the standard wall e-PTFE vascular graft specimens.

Animals↗

Endothelial cell seeding of a 4-mm I.D. polyurethane vascular graft.

We evaluated the extent (luminal coverage) of the endothelial cell (EC) lining/neointimal development and the thromboresistance of electrostatically EC seeded small diameter ChronoFlex-polyurethane vascular grafts. The evaluation consisted of harvesting autologous, canine jugular vein ECs, electrostatically seeding the polyurethane grafts (4-mm I.D., length = 6 cm) with the harvested ECs, implanting the grafts in a canine femoral artery model for four to six weeks, and excising the grafts for histological and scanning electron microscopy evaluations. Results of the histological evaluation (mid-graft region only) indicated that electrostatic EC seeding led to neointimal development and to minimal to no thrombus formation within the EC seeded grafts. The unseeded control grafts resulted in no neointimal development and substantial thrombus formation on the graft luminal surfaces. Scanning electron microscopy examination demonstrated a mature, confluent endothelium with a "cobblestone" appearance on the EC seeded graft luminal surface after six weeks. We conclude that electrostatic EC seeding enhanced the development of a neointima and reduced the incidence of thrombosis in polyurethane grafts implanted in a canine femoral artery model.

Animals↗

Electrospinning of collagen nanofibers.

Electrospinning is a fabrication process that uses an electric field to control the deposition of polymer fibers onto a target substrate. This electrostatic processing strategy can be used to fabricate fibrous polymer mats composed of fiber diameters ranging from several microns down to 100 nm or less. In this study, we describe how electrospinning can be adapted to produce tissue-engineering scaffolds composed of collagen nanofibers. Optimizing conditions for calfskin type I collagen produced a matrix composed of 100 nm fibers that exhibited the 67 nm banding pattern that is characteristic of native collagen. The structural properties of electrospun collagen varied with the tissue of origin (type I from skin vs type I from placenta), the isotype (type I vs type III), and the concentration of the collagen solution used to spin the fibers. Electrospinning is a rapid and efficient process that can be used to selectively deposit polymers in a random fashion or along a predetermined and defined axis. Toward that end, our experiments demonstrate that it is possible to tailor subtle mechanical properties into a matrix by controlling fiber orientation. The inherent properties of the electrospinning process make it possible to fabricate complex, and seamless, three-dimensional shapes. Electrospun collagen promotes cell growth and the penetration of cells into the engineered matrix. The structural, material, and biological properties of electrospun collagen suggest that this material may represent a nearly ideal tissue engineering scaffold.

Animals↗

Mechanical properties and cellular proliferation of electrospun collagen type II.

A suitable technique for articular cartilage repair and replacement is necessitated by inadequacies of current methods. Electrospinning has potential in cartilage repair by producing scaffolds with fiber diameters in the range of native extracellular matrix. Chondrocytes seeded onto such scaffolds may prefer this environment for differentiation and proliferation, thus approaching functional cartilage replacement tissue. Scaffolds of collagen type II were created by an electrospinning technique. Individual scaffold specimens were prepared and evaluated as uncross-linked, cross-linked, or crosslinked/seeded. Uncross-linked scaffolds contained a minimum and average fiber diameter of 70 and 496 nm, respectively, whereas cross-linked scaffolds possessed diameters of 140 nm and 1.46 microm. The average thickness for uncross-linked scaffolds was 0.20 +/- 0.02 mm and 0.52 +/- 0.07 mm for cross-linked scaffolds. Uniaxial tensile tests of uncross-linked scaffolds revealed an average tangent modulus, ultimate tensile strength, and ultimate strain of 172.5 +/- 36.1 MPa, 3.3 +/- 0.3 MPa, and 0.026 +/- 0.005 mm/mm, respectively. Scanning electron microscopy of cross-linked scaffolds cultured with chondrocytes demonstrated the ability of the cells to infiltrate the scaffold surface and interior. Electrospun collagen type II scaffolds produce a suitable environment for chondrocyte growth, which potentially establishes the foundation for the development of articular cartilage repair.

Adult↗