PubMed Health⌕ Search

Biomedical subjects

Gary L Schaer

Publications and source records attributed to Gary L Schaer.

20 records · Page 2Linked to original sources

Predictors of late cardiac events following treatment with Sr-90 beta-irradiation for instent restenosis.

BACKGROUND: Intracoronary radiation therapy (IRT) with Sr-90 using the Novoste Beta-Cath system has been shown to be an effective therapy for instent restenosis (ISR), but the temporal occurrence of cardiac events and the predictors of late complications require further investigation. METHODS: We analyzed the demographics, lesion characteristics and clinical outcomes of 138 consecutive patients with ISR treated with IRT from September 1998 to March 2002. Major adverse cardiac events (MACE) were defined as death, myocardial infarction (MI) or target vessel revascularization (TVR). Characteristics of early (< or =8 months) and late (>8 months) failures were analyzed. RESULTS: Thirty-two (23.1%) of 138 patients had MACE on follow-up; 25% (8/32) of failures occurred late after treatment with IRT. A comparison of the clinical and angiographic profile of early and late failures using univariate analysis indicates no correlations to late failure following IRT. Duration to failure after IRT was 14.25+/-3.69 months in the late group compared to 4.63+/-2.86 months in the early group (P<.001). CONCLUSIONS: Late MACE after IRT with Sr-90 for ISR occur beyond the traditional period for clinical restenosis in 25% of cases and are difficult to predict. Further study is warranted to identify patients at risk for the development of late complications after IRT.

Aged↗

Erosion of an extrapericardial implantable cardioverter defibrillator patch through the gastric fundus with fistulous tract formation.

Until as recently as the mid-1990s, implantable cardioverter defibrillator (ICD) leads were placed through thoracotomy as anterior and/or posterolateral patches. The defibrillator patches have reportedly been associated with a number of relatively common mechanical complications as well as less common complications, including patch migration or erosion into contiguous structures. We report a previously unreported late complication of epicardial defibrillator patch placement in which patch migration and erosion through the gastric fundus resulted in fistulous tract formation from the mediastinum to the lumen of the stomach. Although surgically implanted epicardial patch defibrillator systems are relatively uncommon in current U.S. practice, these devices are still used when specific anatomic or electrophysiological considerations preclude the use of more common endocardial lead systems. Several thousand patients with epicardial patch leads in place are still believed to be alive in the United States. In these patients, continued vigilance for lead-related complications is appropriate. Prompt surgical intervention is usually warranted when patch migration or complications such as the one described occur.

Defibrillators, Implantable↗