PubMed Health⌕ Search

Biomedical subjects

Gastón A Rodriguez-Granillo

Publications and source records attributed to Gastón A Rodriguez-Granillo.

17 recordsLinked to original sources

Plaque composition in the left main stem mimics the distal but not the proximal tract of the left coronary artery: influence of clinical presentation, length of the left main trunk, lipid profile, and systemic levels of C-reactive protein.

OBJECTIVES: We sought to investigate whether plaques located in the left main stem (LMS) differ in terms of necrotic core content from those sited in the proximal tract of the left coronary artery. BACKGROUND: Plaque composition, favoring propensity to vulnerability, might be nonuniformly distributed along the vessel, which might explain the greater likelihood for plaque erosion or rupture to occur in the proximal but not in the distal tracts of the coronary artery or in LMS. METHODS: A total of 72 patients were included prospectively; 48 (32 men; mean age 57 +/- 11 years; 25 with stable angina and 23 affected by acute coronary syndromes) underwent a satisfactory nonculprit vessel investigation through spectral analysis of intravascular ultrasound radiofrequency data (IVUS-Virtual Histology, Volcano Corp., Rancho Cordova, California). The region of interest was subsequently divided into LMS and LMS carina, followed by 6 consecutive nonoverlapping 6-mm segments in left anterior descending artery in 34 patients or in circumflex artery in 14 patients. RESULTS: Necrotic core content (%): 1) was minimal in LMS (median [interquartile range]: 4.6 [2 to 7]), peaked in the first 6-mm coronary segment (11.8 [8 to 16]; p < 0.01), and then progressively decreased distally; 2) was overall greater in patients with acute coronary syndromes (11.4 [5.5 to 19.8]) than stable angina (7.3 [3.2 to 12.9]; p < 0.001); 3) was largely independent from plaque size; and 4) did not correlate to systemic levels of C-reactive protein or lipid profile. CONCLUSIONS: Plaques located in the LMS carry minimal necrotic content. Thus, they mimic the distal but not the proximal tract of the left coronary artery, where plaque rupture or vessel occlusion occurs more frequently.

Adult↗

Meta-analysis of the studies assessing temporal changes in coronary plaque volume using intravascular ultrasound.

To assess the temporal effect of statin therapy on coronary atherosclerotic plaque volume measured by intravascular ultrasound (IVUS), we searched PubMed for eligible studies published between 1990 and January 2006. Inclusion criteria for retrieved studies were (1) IVUS volume analysis at baseline and follow-up and (2) statin therapy in > or =1 group of patients. All data of interest were abstracted in prespecified structured collection forms. Statistical analysis was performed with Review Manager 4.2. Random-effect weighted mean difference (WMD) was used as summary statistics for comparison of continuous variables. Nine studies of 985 patients (with 11 statin treatment arms) were selected. After a mean follow-up of 9.8 +/- 4.9 months, we found a significant decrease in coronary plaque volume (WMD -5.77 mm(3), 95% confidence interval -10.36 to -1.17, p = 0.01), with no significant heterogeneity across studies (p = 0.47). Prespecified subgroup analyses showed similar trends. Studies in which the achieved low-density lipoprotein (LDL) cholesterol level was <100 mg/dl showed a trend for plaque regression (WMD -7.88 mm(3), 95% confidence interval -16.31 to 0.55, p = 0.07), whereas studies in which the achieved level of LDL cholesterol was > or =100 mg/dl, the trend was less evident (WMD -4.22 mm(3), 95% confidence interval -10.27 to 1.82, p = 0.17). Plaque volume remained essentially unchanged in patients not treated with statins (WMD 0.13 mm(3), 95% confidence interval -4.42 to 4.68, p = 0.96). In conclusion, statin therapy, particularly when achieving the target LDL level, appears to promote a significant regression of coronary plaque volume as measured by IVUS.

Cholesterol, LDL↗

Multislice CT coronary angiography for the detection of burden, morphology and distribution of atherosclerotic plaques in the left main bifurcation.

The aim of the study was to explore the differences in plaque burden at different segments of the left main bifurcation and its relationship with the bifurcation angle using high-resolution multislice CT coronary angiography (MSCT). Patients were evaluated using a 40-row MSCT scanner. One observer assessed the localization, severity and distribution of plaques within the left main (LMCA) bifurcation, whereas another observer defined the angle. Fifty patients were included. The mean heart rate was 59.8 +/- 7.1. Seventeen (34%) patients presented at least wall irregularities in the LMCA and in the ostial LCx, whereas the ostial LAD was affected in 32 (64%) patients. More than 90% of plaques were located opposite to the flow divider. The median bifurcation angle was 88.5 degrees (IQR 68.8 degrees, 101.4 degrees). Of the 18 patients with a normal ostial LAD, 13 (72%) had a bifurcation angle < 88.5 degrees , whereas the 63% of the patients with any LAD disease had an angle >or= 88.5 degrees (P = 0.018). In conclusion, at the left main bifurcation, atherosclerotic plaques are commonly located at the ostial LAD and opposite to the flow divider. The angle of the left main bifurcation and the presence of plaques within the bifurcation are closely related.

Chi-Square Distribution↗

Global characterization of coronary plaque rupture phenotype using three-vessel intravascular ultrasound radiofrequency data analysis.

AIMS: To compare the global characteristics of patients with and without evidence of plaque rupture (PR) in their coronary tree and to evaluate the phenotype of ruptured plaques using intravascular ultrasound (IVUS) radiofrequency data analysis (IVUS-VH). METHODS AND RESULTS: Forty patients underwent three-vessel IVUS-VH interrogation. Twenty-eight PRs were diagnosed in 26 vessels (25.7% of the vessels studied) of 20 patients (50% of the population). Ruptures located in the left anterior descending were clustered in the proximal part of the vessel, whereas ruptures located in the right coronary artery were more distally located (P=0.02). Patients with at least one PR presented larger body mass index (BMI) (28.4+/-3.7 vs. 25.8+/-2.6 kg/m(2), P=0.01) and plaque burden (40.7+/-7.6 vs. 33.7+/-8.4%, P=0.01) than patients without rupture, despite showing similar lumen cross-sectional area (9.6+/-3.3 vs. 9.2+/-2.3 mm(2), P=0.60). Among current smokers, 66.7% presented a PR in their coronary tree. Finally, PR sites showed a higher content of necrotic core compared with minimum lumen area sites (17.48+/-10.8 vs. 13.10+/-6.5%, P=0.03) and a trend towards higher calcified component. CONCLUSION: Patients with at least one PR in their coronary tree presented larger BMI and worse IVUS-derived characteristics compared with patients without PR.

Body Mass Index↗

Modified scan protocol using multislice CT coronary angiography allows high quality acquisitions in obese patients: a case report.

Nearly every cardiovascular functional imaging technique has difficulties in dealing with obese patients and MSCT-CA is not an exception. Excluding such large portion of the coronary population remains a grim limitation of the technique and requires thus a comprehensive re-evaluation. In this report, we show that excellent image quality could be achieved in a morbidly obese patient with the aid of proper management of scan protocols and bolus administration. Providing this complex population an accurate, non-invasive imaging technique represents a major step-forward in cardiovascular imaging.

Contrast Media↗

Application of multislice computed tomography coronary angiography for the diagnostic work-up of acute coronary syndromes.

Multislice computed tomography coronary angiography has evolved as an accurate tool to identify the extent, morphology and distribution of significant lesions in the coronary tree of selected patients. More recently, the indications to perform MSCT have been broadened and have been applied in experimented centers to improve the diagnostic work-up of patients admitted with acute coronary syndromes. We report a case were MSCT was applied to define the diagnosis and guide the therapy of a patient admitted with an acute coronary syndrome.

Aged↗

Reproducibility of intravascular ultrasound radiofrequency data analysis: implications for the design of longitudinal studies.

OBJECTIVES: The purpose of this study was to assess in vivo the reproducibility of tissue characterization using spectral analysis of intravascular ultrasound (IVUS) radiofrequency data (IVUS-VH). BACKGROUND: Despite the need for reproducibility data to design longitudinal studies, such information remains unexplored. METHODS AND RESULTS: IVUS-VH (Volcano Corp., Rancho Cordova, USA) was performed in patients referred for elective percutaneous intervention and in whom a non-intervened vessel was judged suitable for a safe IVUS interrogation. The IVUS catheters used were commercially available catheters (20 MHz, Volcano Corp., Rancho Cordova, USA). Following IVUS-VH acquisition, and after the disengagement and re-engagement of the guiding catheter, an additional acquisition was performed using a new IVUS catheter. Fifteen patients with 16 non-significant lesions were assessed by 2 independent observers. The relative inter-catheter differences regarding geometrical measurements were negligible for both observers. The inter-catheter relative difference in plaque cross-sectional area (CSA) was 3.2% for observer 1 and 0.5% for observer 2. The limits of agreement for (observer 1 measurements) lumen, vessel, plaque and plaque burden measurements were 0.82, -1.10 mm(2); 0.80, -0.66 mm(2); 1.08, -0.66 mm(2); and 5.83, -3.89%; respectively. Limits of agreement for calcium, fibrous, fibrolipidic and necrotic core CSA measurements were 0.22, -0.25 mm(2); 1.02, -0.71 mm(2); 0.61, -0.65 mm(2); and 0.43, -0.38 mm(2) respectively. Regarding the inter-observer agreement, the limits of agreement for lumen, vessel, plaque and plaque burden measurements were 2.61, -2.09 mm(2); 2.20-3.03 mm(2); 1.70, -3.04 mm(2); and 9.16, -16.41%; respectively, and for calcium, fibrous, fibrolipidic and necrotic core measurements of 0.08, -0.09 mm(2); 0.89, -1.28 mm(2); 0.74, -1.06 mm(2); and 0.16, -0.20 mm(2); respectively. CONCLUSIONS: The present study demonstrates that the geometrical and compositional output of IVUS-VH is acceptably reproducible.

Coronary Disease↗

Distance from the ostium as an independent determinant of coronary plaque composition in vivo: an intravascular ultrasound study based radiofrequency data analysis in humans.

AIMS: Relative plaque composition, more than its morphology alone, is thought to play a pivotal role in determining propensity to vulnerability. Thus, we investigated in vivo whether the distance from coronary ostium to plaque location independently affects plaque composition in humans. This may help explaining the recently reported non-uniform distribution of culprit lesions along the vessel in acute coronary syndromes. METHODS AND RESULTS: In 51 consecutive patients (45 men), aged 38-76 years (mean age: 58+/-10), a non-culprit vessel was investigated through spectral analysis of IVUS radiofrequency data (IVUS-Virtual Histology). The study vessel was the left anterior descending artery in 23 (45%) patients; the circumflex artery in nine (18%), and right coronary artery in 19 (37%). The overall length of the region of interest, subsequently divided into 10 mm segments, was 41.5+/-13 mm long (range: 30.2-78.4). No significant change was observed in terms of relative plaque composition along the vessel with respect to fibrous, fibrolipidic, and calcified tissue, whereas the percentage of lipid core resulted to be increased in the first (median: 8.75%; IQR: 5.7-18) vs. the third (median: 6.1%; IQR: 3.2-12) (P=0.036) and fourth (median: 4.5%; IQR: 2.4-7.9) (P=0.006) segment. At multivariable regression analysis, distance from the ostium resulted to be an independent predictor of relative lipid content [beta=-0.28 (95%CI: -0.15, -0.41)], together with older age, unstable presentation, no use of statin, and presence of diabetes mellitus. CONCLUSION: Plaque distance from the coronary ostium, as an independent determinant of relative lipid content, is potentially associated to plaque vulnerability in humans.

Adult↗

Coronary plaque composition of nonculprit lesions, assessed by in vivo intracoronary ultrasound radio frequency data analysis, is related to clinical presentation.

BACKGROUND: Identification of subclinical high-risk plaques is potentially important because they may have greater likelihood of rupture and subsequent thrombosis. The purpose of this study was to assess the relationship between plaque composition determined by intravascular ultrasound (IVUS) radio frequency (RF) data analysis and clinical presentation. METHODS: In 55 patients, a nonculprit vessel with < 50% diameter stenosis was studied with IVUS. Tissue maps were reconstructed from RF data using IVUS-Virtual Histology software. RESULTS: Mean percentage of the different plaque components were 0.99% +/- 0.9%, calcium; 68.04% +/- 9.8%, fibrous; 19.31% +/- 7.3%, fibrolipidic; and 9.43% +/- 6.6%, lipid core. Mean lipid core percentage was significantly larger in patients with acute coronary syndrome (ACS) when compared with stable patients (12.26% +/- 7.0% vs 7.40% +/- 5.5%, P = .006). In addition, stable patients showed more fibrotic vessels (70.97% +/- 9.3% vs 63.96% +/- 9.1%, P = .007). There was no significant difference for either mean calcium (1.20% +/- 1.1% vs 0.83% +/- 0.7%, P = .124) or fibrolipidic (20.57% +/- 6.9% vs 18.40% +/- 7.6%, P = .281) percentages in ACS and stable patients, respectively. Vessel area obstruction did not differ between groups (46.49% +/- 10.9% vs 42.83% +/- 11.8%, P = .221). There was a significant, albeit weak, positive correlation between lipid core percentage and stenosis severity as determined by vessel area obstruction (r = 0.34, P = .015). CONCLUSIONS: In this study, plaque characterization of nonculprit vessels using spectral analysis of IVUS RF data analysis was significantly related to clinical presentation. Percentage of lipid core, a feature related to acute coronary events and worse prognosis, was significantly larger in patients with ACS. Conversely, stable patients showed more fibrotic content.

Aged↗

In vivo relationship between compositional and mechanical imaging of coronary arteries. Insights from intravascular ultrasound radiofrequency data analysis.

OBJECTIVE: We sought to explore in vivo the relation between mechanical and compositional properties of matched cross sections (CSs) using novel catheter-based techniques. BACKGROUND: Intravascular ultrasound (IVUS) palpography allows the assessment of local mechanical tissue properties. Spectral analysis of IVUS radiofrequency data (IVUS-VH) is a tool to assess plaque morphology and composition. METHODS AND RESULTS: Palpography analysis defined high- and low-strain regions. One hundred twenty-three CSs (27 vessels) were colocalized. The mean strain value was higher in CSs with necrotic core (NC) in contact with the lumen than in CSs with no NC contact with the lumen (1.03 +/- 0.5 vs 0.86 +/- 0.4, P = .06). Mean relative calcium (1.61 +/- 2.5% vs 0.25 +/- 0.7%, P = .001) and NC (15.64 +/- 10.6% vs 2.8 +/- 3.9%, P < .001) content were significantly higher in the CSs with NC in contact with the lumen, whereas the inverse was seen for the fibrotic component of the plaque (64.16 +/- 11.6% vs 75.75 +/- 13.7, P < .001). The sensitivity, specificity, positive predictive value, and negative predictive value of IVUS-VH to detect high strain were 75.0%, 44.4%, 56.3%, and 65.1%, respectively. A significant inverse relationship was present between calcium and strain levels (r = -0.20, P = .03). After adjusting for univariate predictors, the contact of NC with the lumen was identified as the only independent predictor of high strain (OR 5.0, 95% CI 1.7-14.1, P = .003). CONCLUSION: In the present study, IVUS-VH showed an acceptable sensitivity to detect high strain. In turn, the specificity was low. Of interest, a significant inverse relationship was present between calcium and strain levels.

Aged↗

In vivo variability in quantitative coronary ultrasound and tissue characterization measurements with mechanical and phased-array catheters.

BACKGROUND: Both mechanical and phased-array catheters are used in clinical trials to assess quantitative parameters. Only limited evaluation of the in vivo agreement of volumetrical measurements between such systems has been performed, despite the fact that such information is essential for the conduction of atherosclerosis regression trials. METHODS AND RESULTS: We prospectively evaluated the agreement in morphometric measurements and intravascular ultrasound (IVUS)-based plaque characterization between a 40 MHz rotating transducer (3.2 F Atlantis, Boston Scientific Corp.) and a 20 MHz phased-array catheter (2.9 F Eagle Eye, Volcano Therapeutics, Rancho Cordova, California) in 16 patients. Lumen (7.3+/-2.0 mm(2) vs. 6.7+/-1.8 mm(2), p=0.001) and vessel (11.8+/-3.3 mm(2) vs. 11.0+/-2.9 mm(2), p=0.02) cross-sectional areas (CSA) were significantly greater with the 20 MHz system. Plaque CSA measurements showed no significant difference between systems (4.4+/-2.3 mm(2) vs. 4.4+/-2.1). The relative differences were less than 10% for the three variables. On IVUS-based tissue characterization (13 patients), calculated percentage hypoechogenic volume was significantly higher for the 20 MHz system (96.7+/-2.38 vs. 88.4+/-5.53, p<0.0001). CONCLUSIONS: Quantitative IVUS analyses display significant catheter type-dependent variability. It is unclear whether the variability reflects overestimation of measurements with the phased-array or underestimation with the mechanical system. Although plaque burden measurements did not differ significantly between systems, it appears prudent to recommend the use of a single system for progression/regression studies.

Aged↗

In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis.

OBJECTIVES: The purpose of this study was to assess the prevalence of intravascular ultrasound (IVUS)-derived thin-cap fibroatheroma (IDTCFA) and its relationship with the clinical presentation using spectral analysis of IVUS radiofrequency data (IVUS-Virtual Histology [IVUS-VH]). BACKGROUND: Thin-cap fibroatheroma lesions are the most prevalent substrate of plaque rupture. METHODS: In 55 patients, a non-culprit, non-obstructive (<50%) lesion was investigated with IVUS-VH. We classified IDTCFA lesions as focal, necrotic core-rich (> or =10% of the cross-sectional area) plaques being in contact with the lumen; IDTCFA definition required a percent atheroma volume (PAV) > or =40%. RESULTS: Acute coronary syndrome (ACS) (n = 23) patients presented a significantly higher prevalence of IDTCFA than stable (n = 32) patients (3.0 [interquartile range (IQR) 0.0 to 5.0] vs. 1.0 [IQR 0.0 to 2.8], p = 0.018). No relation was found between patient's characteristics such as gender (p = 0.917), diabetes (p = 0.217), smoking (p = 0.904), hypercholesterolemia (p = 0.663), hypertension (p = 0.251), or family history of coronary heart disease (p = 0.136) and the presence of IDTCFA. A clear clustering pattern was seen along the coronaries, with 35 (35.4%), 31 (31.3%), 19 (19.2%), and 14 (14.1%) IDTCFAs in the first 10 mm, 11 to 20 mm, 21 to 30 mm, and > or =31 mm segments, respectively, p = 0.008. Finally, we compared the severity (mean PAV 56.9 +/- 7.4 vs. 54.8 +/- 6.0, p = 0.343) and the composition (mean percent necrotic core 19.7 +/- 4.1 vs. 18.1 +/- 3.0, p = 0.205) of IDTCFAs between stable and ACS patients, and no significant differences were found. CONCLUSIONS: In this in vivo study, IVUS-VH identified IDTCFA as a more prevalent finding in ACS than in stable angina patients.

Aged↗

In-vivo, cardiac-cycle related intimal displacement of coronary plaques assessed by 3-D ECG-gated intravascular ultrasound: exploring its correlate with tissue deformability identified by palpography.

BACKGROUND: ECG-gated image acquisition of intravascular ultrasound (IVUS) has been shown to provide more accurate measurements at different phases of the cardiac cycle. OBJECTIVE: We sought to explore the ability dynamic assessment of ECG-gated 3-D IVUS to identify deformable regions of coronary plaques, by testing the hypothesis that at a given pressure and region, a faster displacement of the intima would correspond to high strain (soft tissue) regions assessed by palpography. METHODS: ECG-gated 3-D IVUS and palpograms were acquired using 30 and 20 MHz IVUS imaging catheters respectively. Frames with high and/or low strain spots identified by palpography were randomly selected and the spots were assigned to a respective quadrant within the cross section. A color-blinded side-by-side view was performed to enable the co-localization of the same region. Subsequently, the pressure driven displacement of the intima was established for each quadrant and a binary score (significant displacement or no displacement) was decided. RESULTS: One hundred and twenty-four quadrants were studied and the prevalence of highly deformable quadrants was low (n=7, 5.6% of the total). The sensitivity, specificity, positive predictive value and negative predictive value of 3-D ECG-gated IVUS to detect deformable quadrants as assessed by palpography were 42.9, 87.2, 16.7, and 96.2% respectively. CONCLUSION: In this pilot in vivo study, the intimal displacement velocity in the radial direction assessed by gray-scale 3-D ECG-gated IVUS failed to correlate with highly deformable regions. However, these preliminary findings suggest that the absence of significant displacement of the intima might be accurate to predict the absence of deformable tissue.

Contrast Media↗

Immediate and one-year outcome of percutaneous intervention of saphenous vein graft disease with paclitaxel-eluting stents.

The aim of this study was to evaluate the outcome after paclitaxel-eluting stent implantation in 40 patients with 52 saphenous vein graft lesions. By Kaplan-Meier estimates, the probability of major adverse cardiac event-free survival for 1 year was 92.5%. A paclitaxel-eluting stent for saphenous vein graft disease appears to be feasible and safe, with a low rate of reintervention at 1 year, but late follow-up is needed to confirm these observations.

Aged↗

Geometrical validation of intravascular ultrasound radiofrequency data analysis (Virtual Histology) acquired with a 30 MHz boston scientific corporation imaging catheter.

Recently, the plaque characterization field was explored with the use of the substrate (frequency domain analysis) rather than the envelope (amplitude or gray-scale imaging) of the intravascular ultrasound (IVUS) radiofrequency data. However, there is no data about the agreement of quantitative outcome between the two methods. The aim of this study was to assess the correlation and agreement between quantitative coronary ultrasound and the geometrical measurements provided by the spectral analysis of ultrasound radiofrequency data [IVUS-Virtual Histology (IVUS-VH), Volcano Therapeutics). Twenty-five patients were included in this study. The IVUS catheter used was a commercially available mechanical sector scanner (Ultracross 2.9 Fr 30 MHz catheter, Boston Scientific) covered with an outer sheath. IVUS-VH significantly underestimated lumen [relative difference (RD)=14.8+/-5.6; P<0.001], vessel (RD=14.1+/-4.8; P<0.001), and plaque (RD=11.5+/-10.8; P<0.001) cross-sectional areas (CSAs). Nevertheless, when adjusted for the ultrasound propagation delay caused by the sheath, relative differences of measurements were remarkably low (0.49%+/-6.3%, P=0.64 for lumen; 2.33%+/-4.6%, P=0.007 for vessel; and 4.2%+/-10.4%, P=0.005 for plaque CSA). These data suggest that the volumetric output of the IVUS-VH software underestimates measurements when acquired with a 30 MHz catheter. However, after applying a mathematical adjustment method for the ultrasound propagation delay caused by the outer sheath of the 30 MHz catheter, relative differences of direct measurements were negligible. These results suggest that ultrasound radiofrequency data analysis could provide, aside from precise compositional data, an accurate geometrical output.

Cardiac Catheterization↗

One-year clinical outcome after coronary stenting of very small vessels using 2.25 mm sirolimus- and paclitaxel-eluting stents: a comparison between the RESEARCH and T-SEARCH registries.

BACKGROUND: The efficacy of sirolimus-eluting stents (SES) compared to paclitaxel-eluting stents (PES) remains unknown. We evaluated the clinical outcomes after implantation of 2.25 mm diameter SES and PES. METHODS AND RESULTS: PES have been used as the stent of choice for all percutaneous coronary interventions as part of the prospective Taxus-Stent Evaluated At Rotterdam Cardiology Hospital (T-SEARCH) Registry. Ninety consecutive patients received at least one 2.25 mm PES (PES group), and were compared with 107 patients who received at least one 2.25 mm SES as part of the RESEARCH registry. The overall population presented high-risk characteristics commonly excluded from most studies. Populations were well-matched. There were 2 (2.2%) incidents of subacute stent thrombosis in the PES group (in a 2.25 mm stent), and none in the SES group. At one year, the cumulative incidence of major adverse cardiac events was 5.6% in the SES group, and 17.8% in the PES group (p = 0.007). After adjustments for other significant univariate variables, presentation with acute coronary syndrome (ACS) (adjusted OR 5.2 [95% CI 1.8-15.0], p = 0.002) and PES utilization (adjusted OR 3.7 [95% CI 1.3-10.5], p = 0.013) were found to be significant independent predictors of major adverse cardiac events (MACE). CONCLUSIONS: In an unselected population treated for very small vessel disease, SES were associated with better 12-month clinical outcomes and the use of PES was identified as an independent predictor of adverse events.

Angioplasty, Balloon, Coronary↗