PubMed Health⌕ Search

Biomedical subjects

Gavin D Dollinger

Publications and source records attributed to Gavin D Dollinger.

2 recordsLinked to original sources

Accelerating the drug optimization process: identification, structure elucidation, and quantification of in vivo metabolites using stable isotopes with LC/MSn and the chemiluminescent nitrogen detector.

Most preclinical leads exhibit poor ADME/PK properties and require optimizing to increase the likelihood of becoming successful pharmaceuticals. As a means of accelerating the evaluation of these leads in vivo, we assessed the use of LC/MS with the chemiluminescent-nitrogen detector (CLND) and a stable isotope to identify and quantify in vivo metabolites and to measure excretion. A 14C-labeled preclinical lead that also contained two chlorine atoms was administered orally to rats, and samples of bile, urine, and plasma were collected and analyzed by LC with radiodetection and by LC/MS-CLND with the chlorine atoms used as tracers. Both methods identified seven metabolites in bile and two metabolites in urine. The amount and abundance of each metabolite was measured, and the results were equivalent for the two methods. Material balance was measured by liquid scintillation counting of the starting samples, by LC/radiodetection, and by LC/MS-CLND. All three methods yielded the same results and showed that the primary route of clearance was metabolism followed by immediate excretion. This study demonstrates that LC/MS-CLND with a stable isotope is a method that can efficiently track and accurately quantify metabolites, making it possible to rapidly study ADME/PK in vivo without radiolabeling.

Animals↗

An automated LC method for the small-scale purification of organic molecules derived from combinatorial libraries.

This paper presented the development of an automated HPLC small-scale purification method for single bead compounds derived from combinatorial libraries. The method was found to produce higher and more consistent recoveries of purified compounds as compared to conventional manual HPLC purification. Using the manual method, the average percentage recovery of one synthetic compound was determined to be 24% and the coefficients of variation (C.V.%) of recovery were found to be greater than 38%. Using the automated system, the average percentages recovery of a standard compound at 600 and 1000 micromol l(-1) were determined to be 72.63+/-10.17% and 81.34+/-4.39%, respectively. This represented an approximate 3-folds increase in percentage recovery compared to that of the manual small-scale purification process. It was also found that the C.V.% of recovery were less than 15% at both concentration levels. The development of this automated method was found to be straightforward. The importance and implications of this study were discussed.

Chromatography, High Pressure Liquid↗