Vector-velocity estimation in swept-scan using a K-space approach.

The swept-scan technique (i.e., continuously moving a single-crystal transducer during pulse-echo data acquisition) is used in high-frequency, ultrasonic flow imaging. Relative to the conventional step-scan technique, swept scanning improves the rate of data acquisition and enables near-real-time, high-frequency color flow mapping. However, the continuous transducer movement may have non-negligible effects on accuracy of velocity estimation. This paper introduces a spatial frequency domain (i.e., k-space) approach that quantifies the effects of both lateral and axial motions in a swept scan. It is shown that the k-space representation is equivalent to a Doppler-radio frequency (RF) frequency domain representation, and that transducer movement in the swept-scan technique results in a change in Doppler bandwidth. In addition, a vector velocity estimator is developed based on the proposed k-space approach. Both simulations and flow-phantom experiments were performed to evaluate the performance of the proposed vector velocity estimator. A 45-MHz transducer was scanned at 20 mm/s. The Doppler angle ranged from 29 degrees to 90 degrees, and the flow velocities ranged from 15 to 30 mm/s. The results show that the proposed k-space vector velocity estimator exhibited a mean error of 2.6 degrees for flow-direction estimation, with the standard deviation ranging from 2.2 degrees to 8.2 degrees. In comparison, for the conventional spectral-broadening-based vector velocity estimator ignoring the swept-scan effect, the mean error became 15 degrees and the standard deviations were from 2.7 degrees to 6.6 degrees.

Algorithms↗

ECG triggering and gating for ultrasonic small animal imaging.

Echocardiography (ECG) is routinely used in the clinical diagnosis of cardiac function. The anatomy of the mouse is similar to that of the human, and thus murine ECG has become an effective tool for the assessment of small animal models of human cardiac diseases. Unfortunately, clinical ultrasonic imaging systems are not suitable for murine cardiac imaging due to their limited spatial and temporal resolutions. Murine ECG requires a spatial resolution better than 100 pim, which mandates the use of high-frequency, ultrasonic imaging (i.e., >20 MHz). High-frequency transducer arrays currently are not available, and so such systems use the mechanical scanning of a single-element transducer for which the frame rate is insufficient for directly monitoring the rapid beating of a mouse heart, and thus retrospective image reconstruction is necessary. This paper presents a high-frequency, ultrasonic imaging system for murine cardiac imaging. Two scanning methods have been developed. One is based on ECG triggering and is called the block scanning mode, in which the murine cardiac images from the isovolumic contraction and isovolumic relaxation phases are retrospectively reconstructed within a relatively short data acquisition time using the ECG R-wave as the trigger to the imaging system. The other method is the line scanning mode based on ECG gating, in which both ECG and ultrasound scan lines are continuously acquired over a longer time, enabling images during the entire cardiac cycle to be obtained. It is demonstrated here that the effective frame rate is determined by the pulse repetition frequency and can be up to 2 kHz in the presented system.

Animals↗

Effects of swept scanning on velocity estimation.

The swept-scan technique adopted in high-frequency ultrasound involves mechanically scanning a single-element transducer to acquire image data. Unlike conventional step scanning, where the image data are acquired at discrete positions, the swept-scan technique acquires the image data while the transducer is continuously moving. Such a scanning method is particularly advantageous for Doppler flow estimation because its frame rate is higher than that for the step-scan technique. However, the effects of the transducer motion on the accuracy of velocity estimation have not been studied comprehensively. This study employed a k-space approach to experimentally investigate the effects of swept scanning on both conventional Doppler axial velocity estimation and spectral-broadening-based lateral velocity estimation using a 45-MHz transducer. The results indicate that such effects must be corrected in order to obtain an accurate estimation of flow velocities.

Blood Flow Velocity↗