Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT.

In this paper, we developed an analytical fan-beam reconstruction algorithm that compensates for uniform attenuation in SPECT. The new fan-beam algorithm is in the form of backprojection first, then filtering, and is mathematically exact. The algorithm is based on three components. The first one is the established generalized central-slice theorem, which relates the 1D Fourier transform of a set of arbitrary data and the 2D Fourier transform of the backprojected image. The second one is the fact that the backprojection of the fan-beam measurements is identical to the backprojection of the parallel measurements of the same object with the same attenuator. The third one is the stable analytical reconstruction algorithm for uniformly attenuated Radon data, developed by Metz and Pan. The fan-beam algorithm is then extended into a cone-beam reconstruction algorithm, where the orbit of the focal point of the cone-beam imaging geometry is a circle. This orbit geometry does not satisfy Tuy's condition and the obtained cone-beam algorithm is an approximation. In the cone-beam algorithm, the cone-beam data are first backprojected into the 3D image volume; then a slice-by-slice filtering is performed. This slice-by-slice filtering procedure is identical to that of the fan-beam algorithm. Both the fan-beam and cone-beam algorithms are efficient, and computer simulations are presented. The new cone-beam algorithm is compared with Bronnikov's cone-beam algorithm, and it is shown to have better performance with noisy projections.

Algorithms↗

Cone-beam and fan-beam image reconstruction algorithms based on spherical and circular harmonics.

A cone-beam image reconstruction algorithm using spherical harmonic expansions is proposed. The reconstruction algorithm is in the form of a summation of inner products of two discrete arrays of spherical harmonic expansion coefficients at each cone-beam point of acquisition. This form is different from the common filtered backprojection algorithm and the direct Fourier reconstruction algorithm. There is no re-sampling of the data, and spherical harmonic expansions are used instead of Fourier expansions. As a special case, a new fan-beam image reconstruction algorithm is also derived in terms of a circular harmonic expansion. Computer simulation results for both cone-beam and fan-beam algorithms are presented for circular planar orbit acquisitions. The algorithms give accurate reconstructions; however, the implementation of the cone-beam reconstruction algorithm is computationally intensive. A relatively efficient algorithm is proposed for reconstructing the central slice of the image when a circular scanning orbit is used.

Algorithms↗

Nonuniform noise propagation by using the ramp filter in fan-beam computed tomography.

It is observed that when the homogeneity property of the ramp filter is used to derive a filtered backprojection algorithm in fan-beam tomography, the reconstructed images have nonstationary frequency components and nonstationary noise. When a short focal-length is used, higher frequency components are amplified more at the edge of the image than at the center of the image, resulting in higher noise at the edge of the image.

Algorithms↗

Image reconstruction algorithm for a spinning strip CZT SPECT camera with a parallel slat collimator and small pixels.

This paper discusses the use of small pixels in a spinning CdZnTe single photon emission computed tomography (SPECT) camera that is mounted with a parallel slat collimator. In a conventional slat collimation configuration, there is a detector pixel between two adjacent collimator slats. In our design, the pixel size is halved. That is, there are two smaller pixels to replace a regular pixel between two adjacent slats while the collimator remains unchanged. It has an advantage over our older design that uses tilted slats. In order to acquire a complete data set the tilted-slat collimator must spin 360 degrees at each SPECT view while the proposed design requires only 180 degrees at each SPECT view. Computer simulations and phantom experiments have been carried out to investigate the performance of the small-pixel configuration. It is observed that this design has the potential to increase the spatial resolution of the detector while keeping photon counts the same.

Algorithms↗

Diffusion tensor MR imaging of principal directions: a tensor tomography approach.

A novel approach to reconstructing the principal directions of a diffusion tensor field directly from magnetic resonance imaging (MRI) data using a tensor tomography data acquisition approach was developed. If tensor eigenvalues are assumed to be known, the reconstruction of principal directions requires fewer measurements than the reconstruction of the full tensor field. The tensor tomography data acquisition method (rotating diffusion gradients) leads to a unique reconstruction of principal directions, whereas the conventional MRI acquisition technique (stationary diffusion gradients) leads to an ambiguous reconstruction of principal directions when the same number of measurements are used. A computer-generated phantom was used to simulate the diffusion tensor field in the mid-ventricular region of the myocardium. The principal directions of the diffusion tensor field were assumed to align with the fibre structure of the myocardium. An iterative algorithm was used to reconstruct the principal directions. Computer simulations verify that the proposed method provides accurate reconstruction of the principal directions of a diffusion tensor field.

Algorithms↗

Image reconstruction algorithm for a rotating slat collimator.

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted planar integrals of the object. This paper describes the development of an approximate three-dimensional image reconstruction algorithm for a rotating/spinning slat collimator. This algorithm is in filtered backprojection form. Computer simulations were performed to verify the effectiveness of the algorithm.

Algorithms↗