Cataract surgery with the AlphaCor artificial cornea.

PURPOSE: To review the outcomes of AlphaCor artificial cornea (Argus Biomedical Pty Ltd.) implantation concurrent with or subsequent to cataract surgery. SETTING: Nonrandomized multicenter clinical trial. METHODS: AlphaCor devices were implanted under an approved protocol. Extracapsular cataract extraction with intraocular lens implantation was concurrently performed in 5 cases; an additional case had a displaced cataractous lens removed after severe blunt trauma subsequent to AlphaCor implantation. RESULTS: Cataract surgery was difficult because the view was restricted and residual soft lens matter was retained. There was an increased incidence of postoperative complications (eg, melt, glaucoma) in cataract cases compared with noncataract AlphaCor cases. The mean best corrected visual acuity was worse in cases with cataract than in cases without. CONCLUSIONS: The technique for cataract surgery in AlphaCor cases needs to be refined. Imaging studies performed postoperatively may help ascertain whether soft lens matter remains so additional antiinflammatory medication can be considered. Melting appears to be preventable by topical medroxyprogesterone 1% therapy.

Adult↗

Deposits in artificial corneas: risk factors and prevention.

PURPOSE: To identify risk factors for calcium deposition and pigmented staining within AlphaCor artificial corneas. METHODS: Retrospective analysis of data from 72 AlphaCor implantations was conducted. Histological analysis of explants was performed. RESULTS: Eight cases of either intraoptic calcium or pigment deposition occurred in AlphaCor patients between 2.5 and 21 months after implantation. Four cases had diffuse white deposits, confirmed to be calcium and associated with prior coadministration of topical steroids and beta-blockers. The other four cases had brown deposits, associated with cigarette smoking and topical levobunolol. CONCLUSION: These findings led to changes in patient management protocols, surgeon training and patient information so as to minimize the risk of further occurrences. No further cases of white deposition have occurred after warning surgeons of the risk associated with certain topical therapy combinations. The risk of brown staining may be difficult to remove completely as it appears that environmental exposure to chemicals may cause deposition in addition to personal smoking habits and topical medications.

Adrenergic beta-Antagonists↗

Melting after keratoprosthesis implantation: the effects of medroxyprogesterone.

PURPOSE: This study was conducted to evaluate the effect of topical medroxyprogesterone (MPG) following KPro implantation in human subjects in whom donor tissue grafts had been contraindicated by high risk of failure. METHODS: Outcomes of implantation of the Chirila KPro, now known as AlphaCor, were reviewed with respect to postoperative MPG therapy. Ten of 45 (22%) patients had received MPG for a period of 12 months, while 35/45 (78%) had not. MPG treatment was halted because the drug is not approved as an adjunctive treatment of KPro patients. The main outcome measures were the incidence and timing of corneal stromal melting and visual acuity. RESULTS: Of those untreated with MPG, 34% developed a melt (mean follow-up 9.7 months), whereas of those who received MPG, 60% developed a melt (mean follow-up 28.4 months). However, mean time to melt onset for untreated cases was 8.8 months, whereas mean time to melt onset for treated cases was 23.2 months. There is a statistically significant association between time to melt onset, where melts occurred, and MPG therapy (chi2 = 0.001). In both groups, melts were strongly associated with a history of ocular HSV, which represented 17.1% of untreated and 20% of treated cases and is now considered a contraindication for AlphaCor. Preoperative visual acuities were in the range Perception Light (PL)-Count Fingers (CF) in all cases, whereas mean best postoperative best corrected visual acuity was 20/200 (range PL-20/30) in untreated cases and was 20/120 [range Hand Movements (HM)-20/30)] in MPG-treated cases. CONCLUSIONS: Although MPG may not influence the underlying incidence of melt-related complications, which are likely to be associated with other risk factors especially HSV, it may have a protective effect with regard to melt onset and severity. Controlled studies would assist evaluation of its use in this indication.

Administration, Topical↗

AlphaCor cases: comparative outcomes.

PURPOSE: To describe clinical outcomes after a novel type of corneal surgery, implantation of an artificial cornea, AlphaCor , and to evaluate outcomes in comparison with alternative keratoprostheses and high-risk grafts. METHODS: Case reports and data from a noncontrolled clinical trial and a literature review. RESULTS: The probability of AlphaCor retention to 1 year is 80%. Postoperative best corrected visual acuity ranges from Perception Light to 20/30. The most significant complications are stromal melts and optic depositions, for both of which the main risk factors have been identified. Complications can be managed without loss of the eye. CONCLUSION: Results from the clinical trial period have helped to determine the indications and risk factors for AlphaCor surgery and to refine surgical techniques. Continued monitoring of outcomes as the series increases will allow a more accurate determination of comparative outcomes. The series provides preliminary evidence that AlphaCor may have a lower incidence of complications than traditional keratoprostheses and may prove to be preferable to a donor graft in high-risk cases.

Aged↗

The Chirila Keratoprosthesis: phase I human clinical trial.

OBJECTIVE: To undertake a preliminary safety and performance evaluation of an artificial cornea, the Chirila Keratoprosthesis, in human patients. DESIGN: A prospective, interventional case series. PARTICIPANTS: Fourteen consecutive patients with blindness of corneal origin not treatable by repeated standard penetrating keratoplasty. METHODS: Keratoprostheses were manufactured and implanted. The patients, all with preoperative visual acuity of light perception to count fingers (CF), were followed clinically in adherence to a protocol. MAIN OUTCOME MEASURES: Safety (keratoprosthesis retention, incidence of serious complications) and performance (visual acuity, comfort, appearance). RESULTS: Ninety-three percent of keratoprostheses were retained to the date of reporting, up to 2.5 years. One keratoprosthesis (7%) was removed in a manner that restored the patient's preoperative condition. All but one patient maintained their preoperative level of visual acuity or improved on it, with most achieving their estimated full potential visual acuity, (range, count fingers - 20/20). CONCLUSIONS: This keratoprosthesis is acceptably safe and has demonstrated an ability to restore vision in cases in which alternative management would have had a poor prognosis. More extensive trials are warranted.

Cornea↗

Outcomes of implantation of an artificial cornea, AlphaCor: effects of prior ocular herpes simplex infection.

PURPOSE: To review outcomes of AlphaCor artificial cornea implantation in patients with and without a history of ocular herpes simplex virus (HSV) and to determine whether herpetic eye disease is an indication for AlphaCor surgery. METHODS: Outcomes of the initial 40 implantations were reviewed and stratified by the presence of a history of ocular disease caused by HSV. Outcomes measures (complications, visual acuity gained) were compared. RESULTS: Eight of the 40 AlphaCor implantations (20%) were in patients with a history of ocular HSV. Six of these eight patients (75%) developed melt-related complications after AlphaCor insertion. Half of the affected patients required removal of the AlphaCor and replacement with a donor corneal graft to restore ocular integrity. In comparison, only six of the 32 (18.8%) patients without HSV developed a melt after AlphaCor insertion. Patients with HSV with devices in situ exhibited a mean loss of 0.3 line of best-corrected visual acuity compared with the preoperative visual acuity, whereas patients without HSV exhibited a mean gain of 1.4 lines of best-corrected visual acuity. CONCLUSIONS: The extensive lamellar corneal surgery involved in AlphaCor implantation may precipitate reactivation of latent HSV such that reactivation and resultant inflammation reduce device biointegration and facilitate melting of corneal stromal tissue anterior to the device. Although there may be some benefit from systemic antiviral medication, the current series is not large enough to demonstrate such a benefit, and melting can occur despite medication. The statistically significant difference in outcomes between recipients of AlphaCor with and without HSV is evidence that a history of HSV should be an exclusion factor for AlphaCor surgery.

Artificial Organs↗