Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm(3)-525 mm(3)), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (+/-7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (+/-11.1%) for the GE scanner, 9.7% (+/-9.6%) for the Philips scanner and 7.5% (+/-7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm(3). Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies.

Analysis of Variance↗

Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

OBJECTIVE: We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS: Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed enhancement magnetic resonance imaging was performed 15 minutes after the injection of 0.2 mmol/kg Gd-DTPA. On the same day, retrospectively ECG-gated MSCT was performed at 120, 100, and 80 kV (16x0.75mm, 550mAseff.) 15 minutes after the injection of 140 mL of iopromide (1 g/iodine/kg). The pigs were killed and the hearts were excised and stained with 2,3,5-triphenyltetrazolium chloride. The area of acute MI, contrast-to-noise ratio (CNR), and percent signal difference were compared among the different imaging techniques by applying Bland-Altman plots and 2-way analysis of variance. RESULTS: On MSCT at 120, 100, and 80 kV, the respective mean acute MI sizes were 18.4+/-11.4%, 19.3+/-11.5%, and 20.5+/-11.6%. The mean MI sizes were 20.8+/-12.2% and 20.1+/-12.4% on magnetic resonance imaging and 2,3,5-triphenyltetrazolium chloride staining. Analysis of variance did not show any statistically significant differences between the different techniques with respect to the size of acute MI (P=0.9880). Comparing the different kV settings on MSCT, the highest percent signal difference (74.7+/-12.1%) and the highest CNR (6.7+/-1.8) between infarcted and healthy remote myocardium were achieved at 80 kV. CONCLUSIONS: When compared with routine scan protocols, low tube voltage MSCT allows for the assessment of the MI size with an improved CNR and contrast resolution. This technique appears to be advantageous for assessing myocardial viability from contrast enhanced late-phase MSCT.

Animals↗

Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

The purpose of this study was to evaluate a new algorithm for the prediction of contrast enhancement from test bolus data in cardiac multislice spiral computed tomography (MSCT). An algorithm for the prediction of contrast enhancement using test bolus data was developed. A total of 30 consecutive patients (15 male, 69.5 +/- 9.6 years) underwent cardiac MSCT (12 x 0.75 mm, 120 kV, 500 mAs(eff.)) with a biphasic contrast material injection protocol. Contrast timing was derived from a standard 20 ml test bolus injection. Based on the test bolus time attenuation curves, expected enhancement values were computed for the ascending and descending aorta and the pulmonary trunk and compared with measured data from the cardiac CT scan. At the level of the test bolus measurement in the ascending aorta, the corresponding attenuation values were 309.4 +/- 49.6 Hounsfield Units (HU) for the predicted and 285.6 +/- 42.6 HU for the measured attenuation, respectively. The mean deviation between predicted and measured CT values was 32.8 +/- 48.2 HU (upper and lower limits of agreement 101.4/-53.8 HU), indicating a slight systematic tendency for overestimation. For 80% of the patients the prediction error was less than 50 HU. Prediction of contrast enhancement in cardiac MSCT from test bolus data is feasible with a relatively small mean deviation; 80% of the predictions were within a range that might be acceptable for routine clinical application.

Aged↗

Cardiac CT: coronary arteries and beyond.

Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles and essentials of these technical basics are described here. Correctly applied cardiac MDCT allows imaging of the coronary arteries including coronary anatomy and stenosis detection. The same is true for evaluation of coronary artery bypass grafts and, to some extent, coronary artery stents. While quantification of total calcified plaque burden has been long established, coronary MDCT allows assessing plaque morphology and constitution. Recent approaches go beyond the coronaries and include evaluation of left ventricular function at rest and myocardial viability. In combination with experimental approaches for assessing aortic valve function and myocardial perfusion imaging, cardiac MDCT offers the potential for a comprehensive examination of the heart using a single breath-hold examination.

Calcinosis↗

Imaging of the coronary venous system: retrograde coronary sinus angiography versus venous phase coronary angiograms.

BACKGROUND: Left ventricular lead implantation for cardiac resynchronization therapy (CRT) usually requires a pre- or intraprocedural occlusion contrast venography of the coronary sinus (CS) in order to identify tributaries to the lateral wall. As many patients undergo a preprocedural coronary angiogram, we investigated the diagnostic accuracy of venous phase imaging of the CS in patients prior to CRT implantation. The aim of this study was to assess the quality of venous phase coronary sinus angiography. METHODS: In 24 CRT patients retrograde occlusion venography and venous phase coronary sinus angiography obtained during coronary angiography were compared with respect to image quality, vessel diameters and the ability to identify a coronary sinus side branch suitable for left ventricular lead placement. RESULTS: Suitable target vessels for left ventricular lead implantation were identified in all patients irrespective of the method (retrograde occlusion venography or venous phase coronary sinus angiography). There was a high concordance in vessel diameters between venous phase and retrograde angiography. Visibility was superior in retrograde venography. CONCLUSIONS: In heart failure patients who are scheduled for coronary angiograms venous phase coronary sinus angiography is a time-saving and easy to perform alternative imaging modality. Radiation exposure and the amount of contrast medium needed is reduced as compared to coronary sinus occlusion angiography. The information obtained thereby may be used to plan subsequent CRT implantation without the need for retrograde coronary sinus angiography.

Aged↗

Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients.

Cardiac multi-detector-row computed tomography (MDCT) angiography has shown high levels of sensitivity and especially negative predictive value regarding the diagnosis of coronary artery disease (CAD). This study was designed to determine the value of a 64-slice-MDCT scanner in comparison to invasive coronary angiography for the detection of CAD in a population of symptomatic patients. Fifty-one patients with suspected CAD underwent conventional coronary angiography and ECG-gated cardiac 64-slice-MDCT angiography with a rotation time of 330 ms, a collimation of 64x0.6 mm and a slice thickness of 0.75 mm. Blinded patient- and segment-based analysis was performed for the detection of stenoses >or=70% of the vessel lumen. 95% of all coronary segments were assessable by MDCT angiography. Patient-based (segment-based) analysis revealed a sensitivity of 97.8% (86.7%), specificity of 50% (95.2%), positive predictive value of 93.6% (75.2%) and negative predictive value of 75% (97.7%). Inter-rater agreement revealed a kappa-value of 0.558 (0.722). In this symptomatic patient group a 64-slice-MDCT scanner shows good agreement on a segment-based analysis but only moderate agreement on a patient-based analysis. The diagnostic accuracy of 64-slice-MDCT coronary angiography is negatively influenced by the high pre-test probability of this symptomatic patient collective.

Calcinosis↗

Asbestos Surveillance Program Aachen (ASPA): initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT.

The purpose of this study was to assess the prevalence of lung cancer in a high-risk asbestos-exposed cohort using low-dose MDCT. Of a population of 5,389 former power-plant workers, 316 were characterized as individuals at highest risk for lung cancer according to a lung-cancer risk model including age, asbestos exposure and smoking habits. Of these 316, 187 (mean age: 66.6 years) individuals were included in a prospective trial. Mean asbestos exposure time was 29.65 years and 89% were smokers. Screening was performed on a 16-slice MDCT (Siemens) with low-dose technique (10/20 mAs(eff.); 1 mm/0.5 mm increment). In addition to soft copy PACS reading analysis on a workstation with a dedicated lung analysis software (LungCARE; Siemens) was performed. One strongly suspicious mass and eight cases of histologically proven lung cancer were found plus 491 additional pulmonary nodules (average volume: 40.72 ml, average diameter 4.62 mm). Asbestos-related changes (pleural plaques, fibrosis) were visible in 80 individuals. Lung cancer screening in this high-risk cohort showed a prevalence of lung cancer of 4.28% (8/187) at baseline screening with an additional large number of indeterminate pulmonary nodules. Low-dose MDCT proved to be feasible in this highly selected population.

Aged↗

Prevalence and clinical importance of aortic valve calcification detected incidentally on CT scans: comparison with echocardiography.

PURPOSE: To evaluate retrospectively the prevalence and grade of aortic valve calcification incidentally detected on chest multi-detector row computed tomographic (CT) scans and to compare the grade of calcification with the severity of aortic valve disease as assessed with echocardiography. MATERIALS AND METHODS: Patient informed consent was waived by the institutional board on medical ethics that approved this study. The authors identified 402 patients (231 men and 171 women; mean age, 62.5 years +/- 12.1) of 1820 patients who underwent chest multi-detector row CT between July 2001 and August 2004 and also underwent echocardiography. Aortic valve calcification at multi-detector row CT was visually graded on a scale ranging from 0 to 4 (0 = no calcification, 4 = severe calcification). CT findings were correlated with hemodynamic data obtained at echocardiography. Patients without aortic stenosis were compared with patients with aortic stenosis. The Student t test, Spearman correlation coefficient, chi(2) analysis, and an unweighted kappa test were used to compare results. RESULTS: Aortic valve calcification was noted on multi-detector row CT scans in 72 of the 402 patients (18%). Twelve of 20 patients (60%) with grade 3 or grade 4 calcification on CT scans had aortic stenosis at echocardiography, compared with only nine of 382 patients (2.4%) with grade 0-2 calcification (P < .001). Significant correlations were observed between the grade of aortic valve calcification and the echocardiographically determined mean (r = 0.45, P = .03) and peak transvalvular gradient (r = 0.47, P = .03). There was substantial agreement between the grade of valve calcification at multi-detector row CT and the severity of aortic valve disease at echocardiography (kappa = 0.67). CONCLUSION: Aortic valve calcification was an incidental finding on 18% of multi-detector row CT scans. The grade of aortic valve calcification is correlated with the hemodynamic severity of aortic valve disease as determined with echocardiography.

Aortic Valve↗

The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo.

The accuracy of coronary calcium scoring using 16-row MSCT comparing 1- and 3-mm slices was assessed. A thorax phantom with calcium cylinder inserts was scanned applying a non-enhanced retrospectively ECG-gated examination protocol: collimation 12 x 0.75 mm; 120 kV; 133 mAs(eff). Thirty-eight patients were examined using the same scan protocol. Image reconstruction was performed with an effective slice thickness of 3 and 1 mm. The volume score, calcium mass and Agatston score were determined. Image noise was measured in both studies. The volume score and calcium mass varied less than the Agatston score. The overall measured calcium mass compared to the actual calcium mass revealed a relative difference of +2.0% for 1-mm slices and -1.2% for 3-mm slices. Due to increased image noise in thinner slices in the patient study (26.1 HU), overall calcium scoring with a scoring threshold of 130 HU was not feasible. Interlesion comparison showed significantly higher scoring results for thinner slices (all P<0.001). A similar accuracy comparing calcium scoring results of 1- and 3-mm slices was shown in the phantom study; therefore, the potentially necessary increase of the patient's dose in order to achieve assessable 1-mm slices with an acceptable image-to-noise-ratio appears not to be justified.

Aged↗

Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography: comparison with magnetic resonance imaging.

We compared semiautomatic contour detection and manual contour tracing in cardiac multidetector row computed tomography (MDCT) with magnetic resonance imaging (MRI) for calculation of left-ventricular (LV) volumes. The study included 30 patients who underwent contrast-enhanced cardiac MDCT and cardiac cine-MRI. Were calculated 8 mm short-axis slices from MDCT data using three-dimensional multiphase image reconstruction. LV volumes including peak ejection rate and peak filling rate were calculated from manually and semiautomatically determined contours. Results were compared to those from cine-MRI with manually drawn contours as the standard of reference. We found good agreement for the LV volumes, with an ejection fraction of 47.1+/-9.4% for manually drawn contours, 47.9+/-9.9% for semiautomatically detected contours on MDCT, and 48.0+/-10.2% for MRI. Except for peak-filling rate analysis of variance revealed no difference between any of these techniques. Bland-Altman plots and Lin's concordance correlation coefficient showed best agreement between MRI and manual contour tracing in MDCT. Calculation of LV volumes using either semiautomatic or manual contour tracing in cardiac MDCT is therefore feasible when compared to MRI. Automated contour detection needs to be improved to equal manual contour tracing.

Algorithms↗

Variability of aortic valve calcification measurement with multislice spiral computed tomography.

OBJECTIVES: We sought to assess the variability of aortic valve calcifications (AVCs) regarding the reconstruction window at different heart phases using multislice-spiral computed tomography. MATERIALS AND METHODS: A total of 46 patients (26 men; mean age. 65 years) underwent AVC scoring with multislice-spiral computed tomography (12 x 0.75 mm, 120 kV, 133 mAseff). Image reconstruction was performed every 10% of the RR-interval (0-90%). AVC was quantified using Agatston score, calcium volume, and calcium mass. Images were assessed for least motion artifacts. Coefficients of variation and Wilcoxon test were calculated. RESULTS: AVC scores are lowest at 60% and highest at 0% of the RR-interval (P < 0.001). Mean coefficients of variation were 36.2% (Agatston score), 38.7% (calcium volume), and 32.9% (calcium mass). At 60% (50-70%). minimal motion artifacts and the lowest variability of the scores were found. CONCLUSIONS: AVC scores show large variability depending on the point of image reconstruction. Diastolic image reconstruction at 60% of the RR-interval is recommended.

Adult↗

Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study.

PURPOSE: We sought to investigate the influence of heart rate and temporal resolution on the assessment of left-ventricular (LV) function with multislice spiral computed tomography (CT). MATERIAL AND METHODS: A dynamic cardiac phantom was repeatedly scanned with a 64-slice CT scanner using a standardized scan protocol (64 x 0.6 mm, 120kV, 770mAs(eff), 330 milliseconds rotation time) at different simulated heart rates, ranging from 40 to 140 beats per minute. Images were reconstructed with an algorithm utilizing data from 1 to 4 cardiac cycles (RR intervals). Ejection fraction (EF), end-systolic, end-diastolic, and stroke volume as well as cardiac output were calculated. Results of the measurements were compared with the real volumes of the phantom. Interscan and intraobserver variability were calculated. RESULTS: Using a monosegmental reconstruction algorithm, the temporal resolution was fixed to 165 milliseconds. With bi-, tri-, and quad-segmental image reconstruction, mean temporal resolution was 128.3 +/- 33.2 milliseconds, 103.3 +/- 49.2 milliseconds, and 87.8 +/- 81.5 milliseconds, respectively. Multisegmental image reconstruction resulted in a lower deviation when comparing measured and real volumes. Using mono-, bi-, tri-, and quad-segmental image reconstruction, the percent deviation between measured and real values for EF was 8.2%, 4.5%, 3.3%, and 3.4%, respectively. Applying multisegmental image reconstruction with improved temporal resolution the deviation decreased with increasing heart rate when compared with mono-segmental image reconstruction. Interscan and intraobserver variability for EF were 1.1% and 1.9%, respectively. CONCLUSION: Enhanced temporal resolution improves the quantification of LV volumes in cardiac multislice spiral CT, enabling reliable assessment of LV volumes even at increased heart rates.

Algorithms↗

Quantification of aortic valve calcification using multislice spiral computed tomography: comparison with atomic absorption spectroscopy.

OBJECTIVES: Multislice spiral computed tomography (MSCT) allows the in vivo detection of valvular calcification. The aim of this study was to validate the quantification of aortic valve calcification (AVC) by MSCT with in vitro measurements by atomic absorption spectroscopy. METHODS: In 18 patients with severe aortic stenosis, 16 detector row MSCT (SOMATOM Sensation 16, Siemens, Forchheim, Germany with scan parameters as follows: 420 milliseconds tube rotation time, 12 x 0.75 mm collimation, tube voltage 120 KV) was performed before aortic valve replacement. Images were reconstructed at 60% of the RR interval with an effective slice thickness of 3 mm and a reconstruction increment of 2 mm. AVC was assessed using Agatston AVC score, mass AVC score, and volumetric AVC score. After valve replacement, the calcium content of the excised human stenotic aortic valves was determined in vitro using atomic absorption spectroscopy. RESULTS: The mean Agatston AVC score was 3,842 +/- 1,790, the mean volumetric AVC score was 3,061 +/- 1,406, and mass AVC score was 888 +/- 492 as quantified by MSCT. Atomic absorption spectroscopy showed a mean true calcification mass (Ca5(PO4)3OH) of 19 +/- 8 mass%. There was a significant correlation between in vivo AVC scores determined by MSCT and in vitro mean true calcification mass (r = 0.74, P = 0.0004 for mass AVC score, r = 0.79, P = 0.0001 for volumetric AVC score and r = 0.80, P = 0.0001 for Agatston AVC score) determined by atomic absorption spectroscopy. Linear regression analysis showed a significant association between the degree of hydroxyapatite (given in mass%) in the aortic valve and the degree of AVC (R = 0.74, F = 19.6, P = 0.0004 for mass AVC score, R = 0.80, F = 29.3, P = 0.0001 for Agatston AVC score and R = 0.79, F = 27.3, P = 0.0001 for volumetric AVC score) assessed by MSCT. CONCLUSION: MSCT allows accurate in vivo quantification of aortic valve calcifications.

Aged↗

Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol.

OBJECTIVES: We sought to compare an 80-kVp coronary calcium scoring protocol with the standard protocol of 120 kVp in terms of accuracy and reproducibility and to assess its dose reduction potential. MATERIALS AND METHOD: An anthropomorphic heart phantom with calcium cylinders was scanned with different tube currents at 80 kVp and 120 kVp using a 16-slice multislice CT (MSCT) scanner. An adapted threshold for 80 kVp was calculated. Accuracy and reproducibility for calcium mass, volume, and Agatston score were analyzed using F-tests. The radiation doses needed to produce artifact-free images were determined. RESULTS: Accuracy (measurement errors: mass 120 kVp +4.6%, mass 80 kVp -6.9%, volume 120 kVp +78.8%, volume 80 kVp +58.2%) and reproducibility (F-tests: mass: P = 0.4998, volume: P = 0.9168, Agatston: P = 0.5422) were comparable at both tube voltages. Avoiding the appearance of artificial lesions, a CTDI(w,eff) of 10.7 mGy was needed at 120 kVp versus 4.6 mGy at 80 kVp (dose reduction of 57%). CONCLUSIONS: Using an 80-kVp protocol in coronary calcium scoring, a relevant dose reduction is possible without compromising reproducibility and accuracy.

Analysis of Variance↗

Small pulmonary nodules: effect of two computer-aided detection systems on radiologist performance.

PURPOSE: To prospectively compare the effects of two computer-aided detection (CAD) systems on the detection of small pulmonary nodules at multi-detector row computed tomography (CT) by using a consensus panel decision as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Multi-detector row CT scans were randomly chosen and prospectively evaluated in 25 patients. Two dedicated CAD systems-ImageChecker CT (R2 Technologies, Sunnyvale, Calif) and Nodule Enhanced Viewing (NEV) (Siemens Medical Solutions, Forchheim, Germany)-were used. Results were interpreted by three radiologists with 1, 3, and 6 years of experience. Images were evaluated without and with CAD software. The reference standard was assessed by a consensus panel consisting of all three radiologists and an adjudicator with 8 years of experience. RESULTS: A total of 116 pulmonary nodules (average diameter, 3.4 mm; average volume, 32.05 mm3) were found in all data sets during consensus interpretation, which included findings from the CAD software and all radiologists. Overall sensitivity was 73% with ImageChecker CT and 75% with NEV. Overall sensitivity without CAD was 68% for radiologist 1, 78% for radiologist 2, and 82% for radiologist 3. With ImageChecker CT, sensitivity increased to 79% for radiologist 1, 90% for radiologist 2, and 84% for radiologist 3. With NEV, sensitivity increased to 79% for radiologist 1, 90% for radiologist 2, and 86% for radiologist 3. The average number of false-positive findings was six (range, 0-14) with ImageChecker CT and eight (range, 0-22) with NEV. CONCLUSION: Radiologist performance in the interpretation of multi-detector row CT scans can be improved by using CAD systems, with a reduction in the number of false-negative diagnoses. No statistically significant difference in sensitivity was found between the two CAD systems.

Adult↗

Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm.

The purpose was to evaluate a new semi-automated 3D region-growing segmentation algorithm for functional analysis of the left ventricle in multislice CT (MSCT) of the heart. Twenty patients underwent contrast-enhanced MSCT of the heart (collimation 16 x 0.75 mm; 120 kV; 550 mAseff). Multiphase image reconstructions with 1-mm axial slices and 8-mm short-axis slices were performed. Left ventricular volume measurements (end-diastolic volume, end-systolic volume, ejection fraction and stroke volume) from manually drawn endocardial contours in the short axis slices were compared to semi-automated region-growing segmentation of the left ventricle from the 1-mm axial slices. The post-processing-time for both methods was recorded. Applying the new region-growing algorithm in 13/20 patients (65%), proper segmentation of the left ventricle was feasible. In these patients, the signal-to-noise ratio was higher than in the remaining patients (3.2+/-1.0 vs. 2.6+/-0.6). Volume measurements of both segmentation algorithms showed an excellent correlation (all P<or=0.0001); the limits of agreement for the ejection fraction were 2.3+/-8.3 ml. In the patients with proper segmentation the mean post-processing time using the region-growing algorithm was diminished by 44.2%. On the basis of a good contrast-enhanced data set, a left ventricular volume analysis using the new semi-automated region-growing segmentation algorithm is technically feasible, accurate and more time-effective.

Aged↗

Selective increase of cardiac neuronal sympathetic tone: a catheter-based access to modulate left ventricular contractility.

OBJECTIVES: This study was designed to develop a technique to selectively increase the sympathetic tone to the heart by cardiac sympathetic nerve stimulation (SNS). BACKGROUND: Access to the cardiac sympathetic neurons may allow modulating the adrenergic tone of the heart while avoiding systemic side effects. METHODS: Cardiac sympathetic nerves course within neural sleeves along the subclavian artery. Because of this proximity, transvascular SNS was attempted with electrode catheters inside the subclavian artery in 16 pigs. RESULTS: Right/left (R-/L-) SNS (20 Hz) during ventricular pacing at 200/min evoked a >100% increase of left ventricular systolic pressure (baseline: 51 +/- 1 mm Hg; L-SNS: 118 +/- 26 mm Hg; R-SNS: 116 +/- 33 mm Hg; p < 0.001) while systemic vascular resistance remained unchanged. There was a sigmoid dose-response curve with rapid on- and offset of the effect during SNS initiation/cessation. Positive inotropic effects persisted for 12 h of continued SNS (n = 4). Besides positive dromotropic effects, L-SNS/R-SNS yielded a 41% and 77% sinus rate increase, respectively. CONCLUSIONS: The neural adrenergic tone to the heart can be selectively increased by catheter stimulation of cardiac efferent sympathetic nerves.

Animals↗

Relation of oral anticoagulation to cardiac valvular and coronary calcium assessed by multislice spiral computed tomography.

Vitamin K antagonists, known as oral anticoagulants, affect the synthesis and function of the matrix Gla protein, which is a potent inhibitor of tissue calcification. We performed multislice spiral computed tomography in 86 patients (53 men, mean age 71 +/- 8 years) with calcific aortic valve disease to quantitate the amount of calcification in the aortic valve and coronary arteries. Patients with long-term oral anticoagulation therapy (mean duration 88 +/- 113 months; n = 23) were compared with those without anticoagulation (n = 63). No differences were found in the demographic, clinical, or echocardiographic characteristics between the 2 study groups. Patients on oral anticoagulant therapy had increased coronary calcium (coronary Agatston score 1,561 +/- 1,141 vs 738 +/- 978, respectively; p = 0.024) and valvular calcium (valvular Agatston score 2,410 +/- 1,759 vs 1,070 +/- 1,085, respectively; p = 0.002) compared with patients without anticoagulation treatment. The results of our study have demonstrated that oral anticoagulation may be associated with increased valvular and coronary calcium in patients with aortic valve disease, presumably due to decreased activation of the matrix Gla protein.