PubMed Health⌕ Search

Biomedical subjects

Georg N Duda

Publications and source records attributed to Georg N Duda.

At least 19 recordsLinked to original sources

Mesenchymal stem cells regulate angiogenesis according to their mechanical environment.

In fracture and bone defect healing, MSCs largely drive tissue regeneration. MSCs have been shown to promote angiogenesis both in vivo and in vitro. Angiogenesis is a prerequisite to large tissue reconstitution. The present study investigated how mechanical loading of MSCs influences their proangiogenic capacity. The results show a significant enhancement of angiogenesis by conditioned media from mechanically stimulated compared with unstimulated MSCs in two-dimensional tube formation and three-dimensional spheroid sprouting assays. In particular, proliferation but not migration or adhesion of endothelial cells was elevated. Promotion of angiogenesis was dependent upon fibroblast growth factor receptor 1 (FGFR1) signaling. Moreover, stimulation of tube formation was inhibited by vascular endothelial growth factor receptor (VEGFR) tyrosine kinase blocking. Screening for the expression levels of different soluble regulators of angiogenesis revealed an enrichment of matrix metalloprotease 2, transforming growth factor beta1, and basic fibroblast growth factor but not of vascular endothelial growth factor in response to mechanical stimulation. In conclusion, mechanical loading of MSCs seems to result in a paracrine stimulation of angiogenesis, most likely by the regulation of a network of several angiogenic molecules. The underlying mechanism appears to be dependent on the FGFR and VEGFR signaling cascades and might be mediated by an additional cross-talk with other pathways.

Arthroplasty, Replacement, Hip↗

A survey of formal methods for determining functional joint axes.

Axes of rotation e.g. at the knee, are often generated from clinical gait analysis data to be used in the assessment of kinematic abnormalities, the diagnosis of disease, or the ongoing monitoring of a patient's condition. They are additionally used in musculoskeletal models to aid in the description of joint and segment kinematics for patient specific analyses. Currently available methods to describe joint axes from segment marker positions share the problem that when one segment is transformed into the coordinate system of another, artefacts associated with motion of the markers relative to the bone can become magnified. In an attempt to address this problem, a symmetrical axis of rotation approach (SARA) is presented here to determine a unique axis of rotation that can consider the movement of two dynamic body segments simultaneously, and then compared its performance in a survey against a number of previously proposed techniques. Using a generated virtual joint, with superimposed marker error conditions to represent skin movement artefacts, fitting methods (geometric axis fit, cylinder axis fit, algebraic axis fit) and transformation techniques (axis transformation technique, mean helical axis, Schwartz approach) were classified and compared with the SARA. Nearly all approaches were able to estimate the axis of rotation to within an RMS error of 0.1cm at large ranges of motion (90 degrees ). Although the geometric axis fit produced the least RMS error of approximately 1.2 cm at lower ranges of motion (5 degrees ) with a stationary axis, the SARA and Axis Transformation Technique outperformed all other approaches under the most demanding marker artefact conditions for all ranges of motion. The cylinder and algebraic axis fit approaches were unable to compute competitive AoR estimates. Whilst these initial results using the SARA are promising and are fast enough to be determined "on-line", the technique must now be proven in a clinical environment.

Computer Simulation↗

Physiologically based boundary conditions in finite element modelling.

Finite element analysis has been used extensively in the study of bone loading and implant performance, such as in the femur. The boundary conditions applied vary widely, generally producing excessive femoral deformation, and although it has been shown that the muscle forces influence femoral deflections and loading, little consideration has been given to the displacement constraints. It is hypothesised that careful application of physiologically based constraints can produce physiological deformation, and therefore straining, of the femur. Joint contact forces and a complete set of muscle forces were calculated based on the geometry of the Standardised Femur using previously validated musculoskeletal models. Five boundary condition cases were applied to a finite element model of the Standardised Femur: (A) diaphyseally constrained with hip contact and abductor forces; (B) case A plus vasti forces; (C) case A with complete set of muscle forces; (D) distally constrained with all muscle forces; (E) physiological constraints with all muscle forces. It was seen that only the physiological boundary conditions, case E, produced physiological deflections (< 2.0mm) of the femoral head in both the coronal and sagittal planes, which resulted in minimal reaction forces at the constrained nodes. Strains in the mid-diaphysis varied by up to 600 micro-strain under walking loads and 1000 micro-strain under stair climbing loads. The mode of loading, as indicated by the strain profiles on the cortex also varied substantially under these boundary conditions, which has important consequences for studies that examine localised bone loading such as fracture or bone remodelling simulations.

Compressive Strength↗

Endochondral ossification in vitro is influenced by mechanical bending.

Bone development is influenced by the local mechanical environment. Experimental evidence suggests that altered loading can change cell proliferation and differentiation in chondro- and osteogenesis during endochondral ossification. This study investigated the effects of three-point bending of murine fetal metatarsal bone anlagen in vitro on cartilage differentiation, matrix mineralization and bone collar formation. This is of special interest because endochondral ossification is also an important process in bone healing and regeneration. Metatarsal preparations of 15 mouse fetuses stage 17.5 dpc were dissected en bloc and cultured for 7 days. After 3 days in culture to allow adherence they were stimulated 4 days for 20 min twice daily by a controlled bending of approximately 1000-1500 microstrain at 1 Hz. The paraffin-embedded bone sections were analyzed using histological and histomorphometrical techniques. The stimulated group showed an elongated periosteal bone collar while the total bone length was not different from controls. The region of interest (ROI), comprising the two hypertrophic zones and the intermediate calcifying diaphyseal zone, was greater in the stimulated group. The mineralized fraction of the ROI was smaller in the stimulated group, while the absolute amount of mineralized area was not different. These results demonstrate that a new device developed to apply three-point bending to a mouse metatarsal bone culture model caused an elongation of the periosteal bone collar, but did not lead to a modification in cartilage differentiation and matrix mineralization. The results corroborate the influence of biophysical stimulation during endochondral bone development in vitro. Further experiments with an altered loading regime may lead to more pronounced effects on the process of endochondral ossification and may provide further insights into the underlying mechanisms of mechanoregulation which also play a role in bone regeneration.

Animals↗

Gene identification and analysis of transcripts differentially regulated in fracture healing by EST sequencing in the domestic sheep.

BACKGROUND: The sheep is an important model animal for testing novel fracture treatments and other medical applications. Despite these medical uses and the well known economic and cultural importance of the sheep, relatively little research has been performed into sheep genetics, and DNA sequences are available for only a small number of sheep genes. RESULTS: In this work we have sequenced over 47 thousand expressed sequence tags (ESTs) from libraries developed from healing bone in a sheep model of fracture healing. These ESTs were clustered with the previously available 10 thousand sheep ESTs to a total of 19087 contigs with an average length of 603 nucleotides. We used the newly identified sequences to develop RT-PCR assays for 78 sheep genes and measured differential expression during the course of fracture healing between days 7 and 42 postfracture. All genes showed significant shifts at one or more time points. 23 of the genes were differentially expressed between postfracture days 7 and 10, which could reflect an important role for these genes for the initiation of osteogenesis. CONCLUSION: The sequences we have identified in this work are a valuable resource for future studies on musculoskeletal healing and regeneration using sheep and represent an important head-start for genomic sequencing projects for Ovis aries, with partial or complete sequences being made available for over 5,800 previously unsequenced sheep genes.

Animals↗

Mechanical conditions in the initial phase of bone healing.

BACKGROUND: Bone healing is sensitive to the initial mechanical conditions with tissue differentiation being determined within days of trauma. Whilst axial compression is regarded as stimulatory, the role of interfragmentary shear is controversial. The purpose of this study was to determine how the initial mechanical conditions produced by interfragmentary shear and torsion differ from those produced by axial compressive movements. METHODS: The finite element method was used to estimate the strain, pressure and fluid flow in the early callus tissue produced by the different modes of interfragmentary movement found in vivo. Additionally, tissue formation was predicted according to three principally different mechanobiological theories. FINDINGS: Large interfragmentary shear movements produced comparable strains and less fluid flow and pressure than moderate axial interfragmentary movements. Additionally, combined axial and shear movements did not result in overall increases in the strains and the strain magnitudes were similar to those produced by axial movements alone. Only when axial movements where applied did the non-distortional component of the pressure-deformation theory influence the initial tissue predictions. INTERPRETATION: This study found that the mechanical stimuli generated by interfragmentary shear and torsion differed from those produced by axial interfragmentary movements. The initial tissue formation as predicted by the mechanobiological theories was dominated by the deformation stimulus.

Biomechanical Phenomena↗

CYR61 (CCN1) protein expression during fracture healing in an ovine tibial model and its relation to the mechanical fixation stability.

The formation of new blood vessels is a prerequisite for bone healing. CYR61 (CCN1), an extracellular matrix-associated signaling protein, is a potent stimulator of angiogenesis and mesenchymal stem cell expansion and differentiation. A recent study showed that CYR61 is expressed during fracture healing and suggested that CYR61 plays a significant role in cartilage and bone formation. The hypothesis of the present study was that decreased fixation stability, which leads to a delay in healing, would lead to reduced CYR61 protein expression in fracture callus. The aim of the study was to quantitatively analyze CYR61 protein expression, vascularization, and tissue differentiation in the osteotomy gap and relate to the mechanical fixation stability during the course of healing. A mid-shaft osteotomy of the tibia was performed in two groups of sheep and stabilized with either a rigid or semirigid external fixator, each allowing different amounts of interfragmentary movement. The sheep were sacrificed at 2, 3, 6, and 9 weeks postoperatively. The tibiae were tested biomechanically and histological sections from the callus were analyzed immunohistochemically with regard to CYR61 protein expression and vascularization. Expression of CYR61 protein was upregulated at the early phase of fracture healing (2 weeks), decreasing over the healing time. Decreased fixation stability was associated with a reduced upregulation of the CYR61 protein expression and a reduced vascularization at 2 weeks leading to a slower healing. The maximum cartilage callus fraction in both groups was reached at 3 weeks. However, the semirigid fixator group showed a significantly lower CYR61 immunoreactivity in cartilage than the rigid fixator group at this time point. The fraction of cartilage in the semirigid fixator group was not replaced by bone as quickly as in the rigid fixator group leading to an inferior histological and mechanical callus quality at 6 weeks and therefore to a slower healing. The results supply further evidence that CYR61 may serve as an important regulator of bone healing.

Animals↗

Tibio-femoral joint contact forces in sheep.

Although the sheep has become a standard model for understanding the mechanical conditions that occur after injury and investigating surgical treatments such as osteochondral defect healing and ligament reconstruction, no study has yet evaluated the contact forces that occur in the sheep tibio-femoral joint in vivo. In this study, bone pins, together with reflective markers, were used to measure the 3D kinematics of three sheep hind limbs, simultaneously with the ground reaction forces during repetitions of gait trials. Joint contact forces were then calculated using inverse dynamics and optimisation techniques. Whilst average peak axial tibio-femoral contact forces of 2.1 body weight (BW) were calculated across the 3 sheep, only small medio-lateral and antero-posterior shear forces, averaging 0.7 BW, were determined. Average knee flexion angles ranging from 49 degrees to 70 degrees were observed. From the forces determined in this study, we have provided a better understanding of the mechanical loading environment that occurs in sheep. This has important implications for the interpretation of knee studies in quadrupeds and their relevance to the clinical situation.

Animals↗

Autologous bone marrow-derived cells enhance muscle strength following skeletal muscle crush injury in rats.

Insufficient post-traumatic skeletal muscle regeneration with consecutive functional deficiency continues to be a serious problem in orthopedic and trauma surgery. Transplantation of autologous muscle precursor cells has shown encouraging results in muscle trauma treatment but is associated with significant donor site morbidity. In contrast to this, bone marrow-derived (BMD) cells can be obtained without any functional deficit by puncture. The goal of this study was to examine whether regular muscle regeneration can be improved by local application of autologous BMD cells in a rat model of blunt skeletal muscle trauma. One week after standardized open blunt crush injury to the left soleus muscle, 10(6) autologous BMD cells were injected into the traumatized muscle of male Sprague Dawley rats. Rats of the control group received saline solution as treatment. Three weeks after application, the fast twitch and tetanic contraction capacity of the soleus muscles was measured bilaterally by stimulating the sciatic nerves. Contraction forces of injured soleus muscles in control animals recovered to 39 +/- 10% (tetanic) and 59 +/- 12% (fast twitch) of the contralateral noninjured soleus muscles (p < 0.001). In contrast, autologous BMD cell injection significantly restored contractile forces to 53 +/- 8% (tetanic) and 72 +/- 13% (fast twitch) compared to those observed in contralateral noninjured soleus muscles. Thus, muscle function was significantly increased by BMD cell treatment (tetanic, p = 0.014; fast twitch, p = 0.05). In conclusion, autologous BMD cell grafting leads to an increase in contraction force, 14% in tetanic and 13% in fast twitch stimulation, demonstrating its potential to improve functional outcome after skeletal muscle crush injury.

Animals↗

Instability prolongs the chondral phase during bone healing in sheep.

In this sheep study, we investigated the influence of fixation stability on the temporal and spatial distribution of tissues in the fracture callus. As the initial mechanical conditions have been cited as being especially important for the healing outcome, it was hypothesized that differences in the path of healing would be seen as early as the initial phase of healing. Sixty-four sheep underwent a mid-shaft tibial osteotomy that was treated with either a rigid or a semi-rigid external fixator. Animals were sacrificed at 2, 3, 6 and 9 weeks postoperatively and the fracture calluses were analyzed using radiological, biomechanical and histological techniques. Statistical comparison between the groups was performed using the Mann-Whitney U test for unpaired non-parametric data. In the callus of the tibia treated with semi-rigid fixation, remnants of the fracture haematoma remained present for longer, although new periosteal bone formation during early healing was similar in both groups. The mechanical competence of the healing callus at 6 weeks was inferior compared to tibiae treated with rigid fixation. Semi-rigid fixation resulted in a larger cartilage component of the callus, which persisted longer. Remodeling processes were initiated earlier in the rigid group, while new bone formation continued throughout the entire investigated period in the semi-rigid group. In this study, evidence is provided that less rigid fixation increased the time required for healing. The process of intramembranous ossification appeared during the initial stages of healing to be independent of mechanical stability. However, the delay in healing was related to a prolonged chondral phase.

Animals↗

Osteoclastic activity begins early and increases over the course of bone healing.

Osteoclasts are specialised bone-resorbing cells. This particular ability makes osteoclasts irreplaceable for the continual physiological process of bone remodelling as well as for the repair process during bone healing. Whereas the effects of systemic diseases on osteoclasts have been described by many authors, the spatial and temporal distribution of osteoclasts during bone healing seems to be unclear so far. In the present study, healing of a tibial osteotomy under standardised external fixation was examined after 2, 3, 6 and 9 weeks (n = 8) in sheep. The osteoclastic number was counted, the area of mineralised bone tissue was measured histomorphometrically and density of osteoclasts per square millimetre mineralised tissue was calculated. The osteoclastic density in the endosteal region increased, whereas the density in the periosteal region remained relatively constant. The density of osteoclasts within the cortical bone increased slightly over the first 6 weeks, however, there was a more rapid increase between the sixth and ninth weeks. The findings of this study imply that remodelling and resorption take place already in the very early phase of bone healing. The most frequent remodelling process can be found in the periosteal callus, emphasising its role as the main stabiliser. The endosteal space undergoes resorption in order to recanalise the medullary cavity, a process also started in the very early phase of healing at a low level and increasing significantly during healing. The cortical bone adapts in its outward appearance to the surrounding callus structure. This paradoxic loosening is caused by the continually increasing number and density of osteoclasts in the cortical bone ends. This study clearly emphasises the osteoclastic role especially during early bone healing. These cells do not simply resorb bone but participate in a fine adjusted system with the bone-producing osteoblasts in order to maintain and improve the structural strength of bone tissue.

Animals↗

A survey of formal methods for determining the centre of rotation of ball joints.

The determination of an accurate centre of rotation (CoR) from segment marker positions is of interest across a wide range of applications, but particularly for clinical gait analysis and for estimating the hip joint centre during surgical intervention of the knee, for limb alignment purposes. For the first time in this survey of formal methods, we classify, analyse and compare different methods (geometric, algebraic, bias compensated algebraic, and Pratt sphere fit methods, as well as the centre transformation technique, the Holzreiter approach, the helical pivot technique, the Schwartz transformation techniques, the minimal amplitude point method and the Stoddart approach) for the determination of spherical joint centres from marker position data. In addition, we propose a new method, the symmetrical CoR estimation or SCoRE, in which the coordinates of the joint centre must only remain constant relative to each segment, thus not requiring the assumption that one segment should remain at rest. For each method, 1000 CoR estimations were analysed with the application of isotropic, independent and identically distributed Gaussian noise (standard deviation 0.1cm) to each of the marker positions, to all markers on the segment simultaneously and the two in combination. For the test conditions used here, most techniques were capable of determining the CoR to within 0.3 cm, as long as the spherical range of motion (RoM) of the joint was 45 degrees or more. Under the most stringent conditions tested, however, the SCoRE was capable of best determining the CoR, to within approximately 1.2mm with a RoM of 20 degrees . The correct selection and application of these methodologies should help improve the accuracy of surgical navigation and clinical kinematic measurement.

Biomechanical Phenomena↗

The morphology and biomechanical characteristics of subcutaneously implanted tissue-engineered human septal cartilage.

The purpose of the study was to examine the morphology and biomechanical characteristics of in vivo cultured tissue-engineered human septal cartilage as a prospective autogenous transplant material for subcutaneous implantation in reconstructive procedures. Chondrocytes were enzymatically isolated from human septal cartilage biopsies. The cell number was expanded in monolayer culture. Chondrocytes were then fixed on a non-woven poly-lactide-poly-glycolide (PGLA) polymer scaffold by means of fibrin glue. The PGLA-polymer construct was implanted subcutaneously on the back of athymic mice and allowed to mature for 6 or 12 weeks. After killing the mice, the formed cartilage was tested on a material testing machine with a highly standardized reproducible setting. Biomechanical testing consisted of an indentation test, which revealed the failure load and compressive modulus of the neocartilage. The failure load shows the upper limit of supported stress. The compressive modulus is a measure of the templates' stiffness. After testing, the templates were histologically stained. Native human septal cartilage served as a control group. Histological and macroscopic examination showed cartilage formation of a hyaline-like morphology. Histological staining revealed the synthesis of abundant mucopolysaccharid matrix. The biomechanical characteristics of neocartilage proved to be of no statistical difference compared to native human septal cartilage. The failure load and compressive modulus were initially somewhat lower and reached the control group's results after 12 weeks in-vivo. Summarizing, tissue engineered nasal cartilage matches typical mechanical characteristics of native hyaline cartilage. Its elasticity and failure load are of sufficient quality to meet the clinical requirements for reconstructive surgery.

Animals↗

Stress shielding in box and cylinder cervical interbody fusion cage designs.

STUDY DESIGN: A numerical analysis of stress shielding of the bone graft in box and cylinder interbody fusion cages was performed. OBJECTIVES: To evaluate the stress shielding characteristics of box and cylinder interbody fusion cages for the cervical spine with regard to their rigidity and contiguous pore size. SUMMARY OF BACKGROUND DATA: Cage design has been shown to influence loading of the augmented bone graft tissue. In addition, a large contiguous pore design is believed to be important to avoid stress shielding effects. METHODS: A two-dimensional axisymmetric, biphasic finite-element model of the cage incorporating the bone graft and the adjacent vertebral bodies was developed. Analysis was performed in two parts. First, the vertebrae were loaded by an axial compressive force, and second, the effect of vertebral penetration by the interbody cage was simulated. RESULTS: Straining of bone graft in the box cage was generally lower than that of the cylinder cage. The strains in the cylinder cage were seen to be more uniformly distributed, whereas in the box cage straining was concentrated in the graft under the endplates. Vertebral penetration by the cylinder cage resulted in significant straining of the bone graft (28% strain), whereas lower strains were determined in the box cage (a maximum of 17% strain). CONCLUSIONS: The central pore in the box design does not seem as effective as the fully open cylinder cage in transferring loads to the augmented graft tissue. Early penetration of the adjacent vertebrae by the cylinder cage may provide early postoperative stability and load the graft tissue, thereby imparting the necessary signals for fusion.

Biomechanical Phenomena↗

On the influence of soft tissue coverage in the determination of bone kinematics using skin markers.

Accurate measurement of underlying bone positions is important for the understanding of normal movement and function, as well as for addressing clinical musculoskeletal or post-injury problems. Non-invasive measurement techniques are limited by the analysis technique and movement of peripheral soft tissues that can introduce significant measurement errors in reproducing the kinematics of the underlying bones when using external skin markers. Reflective markers, skeletally mounted to the right hind limb of three Merino-mix sheep were measured simultaneously with markers attached to the skin of each segment, during repetitions of gait trials. The movement of the skin markers relative to the underlying bone positions was then assessed using the Point Cluster Technique (PCT), raw averaging and the Optimal Common Shape Technique (OCST), a new approach presented in this manuscript. Errors in the position of the proximal joint centre, predicted from the corresponding skin markers, were shown to be phasic and strongly associated with the amount soft tissue coverage, averaging 8.5 mm for the femur, 2.8 for the tibia and 2.0 for the metatarsus. Although the results show a better prediction of bone kinematics associated with the Optimal Common Shape Technique, these errors were large for all three assessment techniques and much greater than the differences between the various techniques. Whilst individual markers moved up to 4 mm from the optimal marker set configuration, average peak errors of up to 16, 5 and 3 mm (hip, knee and tibio-metatarsal joints respectively) were observed, suggesting that a large amount of kinematic noise is produced from the synchronous shifting of marker sets, potentially as a result of underlying muscle firing and the inertial effects of heel impact. Current techniques are therefore limited in their ability to determine the kinematics of underlying bones based on skin markers, particularly in segments with more pronounced soft tissue coverage.

Animals↗

On the influence of mechanical conditions in osteochondral defect healing.

Despite the introduction of new surgical techniques, the treatment of cartilage defects remains challenging. Delay or complete failure of cartilage healing is associated with problems in biological regeneration. The influence of mechanical conditions on this process, however, remains unevaluated. Osteochondral defects were generated on the left femoral condyle in 18 Yucatan minipigs. After 4, 6 and 12 weeks the defect filling, trabecular orientation and bone density were compared to the intact contralateral side. The mechanical straining during this period was then analyzed using an adaptive finite element technique. Histologically, the osteochondral defects showed bone resorption at the base and bone formation from the circumference. At 12 weeks, the macroscopically healed specimens showed fibrous cartilage formation, a minimally organized trabecular structure and increased trabecular volume fraction compared to the controls (p < 0.002). The amount of cancellous, cartilagineous, and fibrous tissue and the defect size as measured in histomorphometric analysis for the three time points (4, 6 and 12 weeks) was comparable in magnitude to that predicted by finite element analysis. The simulated osteochondral healing process was not fully capable of re-establishing a hyaline-like cartilage layer. The correlation between simulation and histology allows identification of mechanical factors that appear to have a larger impact on the healing of osteochondral defects than previously considered.

Animals↗

Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro.

Pre-clinical testing of hip endoprostheses is a mandatory requirement before clinical release. Inadequate loading conditions may lead to lower elastic and plastic interface movements than those occurring post-operatively in vivo. This study investigated the influence of patient activity on the primary stability of cementless prostheses with a special emphasis on active simulation of muscle forces. A loading setup, based on validated musculo-skeletal analyses, was used to generate the hip contact force during walking and stair climbing by transmitting muscle forces through the femur. In addition, a loading configuration which only generated the hip contact force occurring during stair climbing at the prosthesis head was simulated. CLS prostheses were implanted in 18 composite femora and subjected to cyclical loading. The relative micro-movements at the bone-prosthesis interface were determined and appeared to be extremely sensitive to the specific patient activity. Compared to walking, stair climbing generated higher micro-movements, with pronounced axial and rotational components. Stair climbing with the femur loaded by the resultant hip contact force only exhibited a characteristic valgus tilt of the stem with significantly lower interface micro-movements than under active simulation of muscle forces. The analyses suggest that stair climbing induced the highest mechanical instability at the bone-prosthesis interface, a level which may compromise the necessary osseointegration process. Active simulation of muscle forces considerably affects the primary stability of cementless hip endoprostheses. Pre-clinical in vitro tests should therefore simulate stair climbing and include muscle activity in the assessment of initial implant stability, otherwise micro-movements may be underestimated and the primary stability overestimated.

Cementation↗

Initial vascularization and tissue differentiation are influenced by fixation stability.

Fracture healing requires a certain degree of mechanical stability and an adequate blood supply. The hypothesis of the present study was that increased interfragmentary shear leads to a reduced initial vascularization and prolonged healing. The aim of the study was to quantitatively analyze the histological appearance of vascularization and tissue differentiation with regard to fracture stability during the course of healing. A mid-shaft osteotomy of the tibia was performed in two groups of sheep and stabilized with either a rigid or semirigid external fixator, differing in bending stiffness. Interfragmentary movements and ground reaction forces were evaluated in vivo during a 9-week period. The sheep were sacrificed at 2, 3, 6, and 9 weeks postoperatively. The tibiae were tested biomechanically and histological sections from the callus were prepared for analysis of tissue differentiation and vascularization. Larger interfragmentary shear movements in the semirigid fixator group were associated with a reduced initial blood supply. At 6 weeks the semirigid fixator group showed a significantly lower percentage of mineralized bone and a higher amount of fibrous tissue leading to a significantly lower stiffness of the callus than the rigid fixator group. This initial delay in healing was compensated for in the later stages with the production of greater volumes of callus tissue so that both groups showed the same callus stiffness at 9 weeks. However, the rigid fixator group showed signs of the beginning of callus remodeling at the latest time points suggesting a faster bone healing. The results indicate the important role of the initial mechanical stability specifically in the vascularization of an osteosynthesis. Further studies should illustrate the precise role of mechanical conditions on the regulation of angiogenesis during early bone healing.

Animals↗