PubMed Health⌕ Search

Biomedical subjects

George A Sandison

Publications and source records attributed to George A Sandison.

13 recordsLinked to original sources

Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies.

Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity.

Algorithms↗

Reconstruction of electron spectra from depth doses with adaptive regularization.

Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned and this may lead to nonphysical oscillations in the reconstructed spectra. Use of a variational method of solution with a regularization technique removes the oscillations but tends to smooth the sharp (deltalike) energy peak that is a common feature in electron spectra generated by medical accelerators. Because the sharp peak contains a large percentage of the electrons in the spectrum, an accurate estimate of the peak width, height and position is critical to the success of the technique for spectrum reconstruction with regularization. We propose use of an adaptive regularization term as a special form of the general Tichonov regularization function. The variational method with the adaptive regularization term is applied to reconstruct electron spectra for the 6, 9, and 18 MeV electron beams of a Varian Clinac 2100C accelerator and proves to be a very simple, effective and accurate approach. Results using this variational method with adaptive regularization almost perfectly reconstruct electron spectra from depth dose distributions.

Electrons↗

Neutron scattered dose equivalent to a fetus from proton radiotherapy of the mother.

Scattered neutron dose equivalent to a representative point for a fetus is evaluated in an anthropomorphic phantom of the mother undergoing proton radiotherapy. The effect on scattered neutron dose equivalent to the fetus of changing the incident proton beam energy, aperture size, beam location, and air gap between the beam delivery snout and skin was studied for both a small field snout and a large field snout. Measurements of the fetus scattered neutron dose equivalent were made by placing a neutron bubble detector 10 cm below the umbilicus of an anthropomorphic Rando phantom enhanced by a wax bolus to simulate a second trimester pregnancy. The neutron dose equivalent in milliSieverts (mSv) per proton treatment Gray increased with incident proton energy and decreased with aperture size, distance of the fetus representative point from the field edge, and increasing air gap. Neutron dose equivalent to the fetus varied from 0.025 to 0.450 mSv per proton Gray for the small field snout and from 0.097 to 0.871 mSv per proton Gray for the large field snout. There is likely to be no excess risk to the fetus of severe mental retardation for a typical proton treatment of 80 Gray to the mother since the scattered neutron dose to the fetus of 69.7 mSv is well below the lower confidence limit for the threshold of 300 mGy observed for the occurrence of severe mental retardation in prenatally exposed Japanese atomic bomb survivors. However, based on the linear no threshold hypothesis, and this same typical treatment for the mother, the excess risk to the fetus of radiation induced cancer death in the first 10 years of life is 17.4 per 10,000 children.

Female↗

Energy response of an aluminium oxide detector in kilovoltage and megavoltage photon beams: an EGSnrc Monte Carlo simulation study.

A Monte Carlo study of the energy response of an aluminium oxide (Al(2)O(3)) detector in kilovoltage and megavoltage photon beams relative to (60)Co gamma rays has been performed using EGSnrc Monte Carlo simulations. The sensitive volume of the Al(2)O(3) detector was simulated as a disc of diameter 2.85 mm and thickness 1 mm. The phantom material was water and the irradiation depth chosen was 2.0 cm in kilovoltage photon beams and 5.0 cm in megavoltage photon beams. The results show that the energy response of the Al(2)O(3) detector is constant within 3% for photon beam energies in the energy range of (60)Co gamma rays to 25 MV X rays. However, the Al(2)O(3) detector shows an enhanced energy response for kilovoltage photon beams, which in the case of 50 kV X rays is 3.2 times higher than that for (60)Co gamma rays. There is essentially no difference in the energy responses of LiF and Al(2)O(3) detectors irradiated in megavoltage photon beams when these Al(2)O(3) results are compared with literature data for LiF thermoluminescence detectors. However, the Al(2)O(3) detector has a much higher enhanced response compared with LiF detectors in kilovoltage X-ray beams, more than twice as much for the case of 50 kV X rays.

Aluminum Oxide↗

Numerical simulation for heat transfer in prostate cancer cryosurgery.

A comprehensive computational framework to simulate heat transfer during the freezing process in prostate cancer cryosurgery is presented. Tissues are treated as nonideal materials wherein phase transition occurs over a temperature range, thermophysical properties are temperature dependent and heating due to blood flow and metabolism are included. Boundary conditions were determined at the surfaces of the commercially available cryoprobes and urethral warmer by experimental study of temperature combined with a mathematical optimization process. For simulations, a suitable computational geometry was designed based on MRI imaging data of a real prostate. An enthalpy formulation-based numerical solution was performed for a prescribed surgical protocol to mimic a clinical freezing process. This computational framework allows for the individual planning of cryosurgical procedures and objective assessment of the effectiveness of prostate cryosurgery.

Body Temperature↗

X-ray CT high-density artefact suppression in the presence of bones.

This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy).

Algorithms↗

The energy-dependent electron loss model: backscattering and application to heterogeneous slab media.

Electron backscattering has been incorporated into the energy-dependent electron loss (EL) model and the resulting algorithm is applied to predict dose deposition in slab heterogeneous media. This algorithm utilizes a reflection coefficient from the interface that is computed on the basis of Goudsmit-Saunderson theory and an average energy for the backscattered electrons based on Everhart's theory. Predictions of dose deposition in slab heterogeneous media are compared to the Monte Carlo based dose planning method (DPM) and a numerical discrete ordinates method (DOM). The slab media studied comprised water/Pb, water/Al, water/bone, water/bone/water, and water/lung/water, and incident electron beam energies of 10 MeV and 18 MeV. The predicted dose enhancement due to backscattering is accurate to within 3% of dose maximum even for lead as the backscattering medium. Dose discrepancies at large depths beyond the interface were as high as 5% of dose maximum and we speculate that this error may be attributed to the EL model assuming a Gaussian energy distribution for the electrons at depth. The computational cost is low compared to Monte Carlo simulations making the EL model attractive as a fast dose engine for dose optimization algorithms. The predictive power of the algorithm demonstrates that the small angle scattering restriction on the EL model can be overcome while retaining dose calculation accuracy and requiring only one free variable, chi, in the algorithm to be determined in advance of calculation.

Algorithms↗

A microscale model for prediction of breast cancer cell damage during cryosurgery.

The morphology of cancerous breast tissue is characterized by tightly packed groups of small malignant cells, as found in most duct cell carcinoma. This special structure affects the osmotic responses of the cells to freezing and hence their probability of damage from cellular dehydration or intracellular ice formation. A mathematical model has been developed to study the microscale damage to these breast cancer cells during cryosurgery by accounting for their special structure. The model is based on a spherical unit comprised of an extracellular region that surrounds several layers of cancer cells, as experimentally observed of breast duct cell carcinoma by other researchers. Temperature transients in the breast cancer undergoing cryosurgery are calculated numerically using the Pennes equation. When subjected to various thermal histories, both cellular dehydration and intracellular ice formation in the unit structure are examined by considering the cell-to-cell contact and water transport at the microscale level. It is found that the cells in the inner layers hardly dehydrated while those in the outermost layer do greatly. The results help interpret the previously observed experimental phenomena that breast cancer tissues exhibit intracellular ice formation even at a slow cooling rate of -3 degrees C/min. In the attempt to better define an optimal procedure for breast cancer cryosurgery, various freezing protocols are simulated. The constant heat flux protocol induces greater cellular dehydration and higher intracellular ice formation probability simultaneously compared to the other protocols studied.

Breast Neoplasms↗

Angular correction in reconstruction of electron spectra from depth dose distributions.

Techniques for reconstruction of electron spectra from the depth-dose curves used to date have ignored the angular distribution of incident electrons scattered at large angles. The approximation adopted is to employ a database of monoenergetic depth-dose curves generated for normal incidence of electrons at the surface. This approximation is acceptable for direct electrons with small angular spread. However, electrons scattered from the treatment head and collimating system may have large average angles of incidence which affects the depth-dose distribution significantly at shallow depths by increasing energy deposition close to the surface. We show that ignoring the electron incident angular distribution leads to systematic errors in the low energy region of reconstructed electron spectra. We propose a simple 1-D model to correct for these systematic errors using only electron angular distribution at the central beam axis. This model provides reconstructed spectra in excellent agreement with Monte Carlo simulation in the low energy region.

Algorithms↗

X-ray CT high-density artefact suppression in cryosurgery.

Advantages of x-ray CT for imaging guidance of cryosurgery include 3D visualization of frozen and unfrozen tissue and calibration of temperature in the tissue water-ice interface (0-10 degrees C) to Hounsfield units. However, use of x-ray CT images and their thermal calibration can be compromised by the cryoprobes generating high-density streak artefacts. A new subtraction technique for artefact suppression is proposed and tested in prostate cryosurgery simulations. By subtracting the measured CT x-ray projection profile without cryoprobes from the profile with cryoprobes plus iceballs, one obtains the combined profile of the cryoprobes and a low value background. Polynomial interpolation to obtain the background profile allows its addition to the original profile without probes. The result may then be fed to a conventional filtered back-projection routine to reconstruct the probe-free image. Finally the cryoprobe pixels in the originally constructed image with probes and iceballs are added back to the probe-free image to get the final artefact-suppressed image. The major advantage of this subtraction technique is that it can successfully suppress the high-density artefacts in bone-abundant body regions such as the pelvis. X-ray CT images of cryoprobe arrays in a homogeneous gelatin phantom and the pelvic region of an anthropomorphic Rando phantom containing a human skeleton were generated. After suppression, cryoprobe metal artefact streaks are reduced and visualization of the positions and dimensions of the cryoprobes are well preserved.

Algorithms↗

Future directions for cryosurgery computer treatment planning.

Computer treatment planning for cryosurgery is an area of research and development that will greatly assist the practicing physician and will promote improved quality assurance for clinical procedures. Good planning and precision image-guided treatment delivery are complementary in achieving an optimal treatment outcome. State-of-the-art cryosurgery treatment planning systems are at an early stage of development in comparison with radiation treatment planning systems for external beams. Using 30 years of progress in the area of radiation treatment planning as a guide, this article presents a summary of the avenues for research and development in cryosurgery treatment planning that are likely to accelerate the practical application of precision cryosurgery to a broad spectrum of anatomical sites. Emphasis is placed on prostate cryosurgery, imaging techniques, and recommendations for manufacturers of these systems. Optimization of the clinical procedure in the planning stage using mathematical algorithms to define the positioning and operation of cryoprobes is discussed.

Algorithms↗

Intensity and energy modulated radiotherapy with proton beams: variables affecting optimal prostate plan.

Inverse planning for intensity- and energy-modulated radiotherapy (IEMRT) with proton beams involves the selection of (i) the relative importance factors to control the relative importance of the target and sensitive structures, (ii) an appropriate energy resolution to achieve an acceptable depth modulation, (iii) an appropriate beamlet width to modulate the beam laterally, and (iv) a sufficient number of beams and their orientations. In this article we investigate the influence of these variables on the optimized dose distribution of a simulated prostate cancer IEMRT treatment. Good dose conformation for this prostate case was achieved using a constellation of I factors for the target, rectum, bladder, and normal tissues of 500, 50, 15, and 1, respectively. It was found that for an active beam delivery system, the energy resolution should be selected on the basis of the incident beams' energy spread (sigmaE) and the appropriate energy resolution varied from 1 MeV at sigmaE = 0.0 to 5 MeV at sigmaE= 2.0 MeV. For a passive beam delivery system the value of the appropriate depth resolution for inverse planning may not be critical as long as the value chosen is at least equal to one-half the FWHM of the primary beam Bragg peak. Results indicate that the dose grid element dimension should be equal to or no less than 70% of the beamlet width. For this prostate case, we found that a maximum of three to four beam ports is required since there was no significant advantage to using a larger number of beams. However for a small number (< or = 4) of beams the selection of beam orientations, while having only a minor effect on target coverage, strongly influenced the sensitive structure sparing and normal tissue integral dose.

Algorithms↗

Reconstruction of electron spectra using singular component decomposition.

Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unstable due to small perturbations in the input data. Predicting the sharp (delta-like) peak in the electron spectrum provides an additional challenge for the numerical reconstruction technique. To improve efficiency and robustness of the reconstruction technique, we developed an algorithm based on a separation of the electron spectrum into singular and regular components. We approximate the singular peak of the spectrum by a narrow weighted Gaussian function. The parameters of this Gaussian function are sought using only the fall-off and toe regions of the depth-dose curve. Analytical representation of the spectral peak by a Gaussian has benefit since only one weight and the mean and variance must be derived from the depth-dose curve instead of multiple spectra weights. The regular part of the spectrum is reconstructed from the residual depth-dose distribution using a variational method combined with a regularization technique to avoid the nonphysical oscillations. The effectiveness of the method is demonstrated by comparing predictions to "benchmark" spectra and depth-dose distributions from Monte Carlo simulation of medical accelerators.

Algorithms↗