PubMed Health⌕ Search

Biomedical subjects

George Horvai

Publications and source records attributed to George Horvai.

8 recordsLinked to original sources

Structure of the liquid-vapor interface of water-methanol mixtures as seen from Monte Carlo simulations.

Monte Carlo simulation of the vapor-liquid interface of water-methanol mixtures of different compositions, ranging from pure water to pure methanol, have been performed on the canonical (N, V, T) ensemble at 298 K. The analysis of the systems simulated has revealed that the interface is characterized by a double layer structure: methanol is strongly adsorbed at the vapor side of the interface, whereas this adsorption layer is followed at its liquid side by a depletion layer of methanol of lower concentration than in the bulk liquid phase of the system. The dominant feature of the interface has been found to be the adsorption layer in systems of methanol mole fractions below 0.2, and the depletion layer in systems of methanol mole fractions between 0.25 and 0.5. The orientation of the molecules located at the depletion layer is found to be already uncorrelated with the interface, whereas the methanol molecules of the adsorption layer prefer to align perpendicular to the interface, pointing straight toward the vapor phase by their methyl group. Although both the preference of the molecular plane for a perpendicular alignment with the interface and the preference of the methyl group for pointing straight to the vapor phase are found to be rather weak, the preference of the methyl group for pointing as straight toward the vapor phase as possible within the constraint imposed by the orientation of the molecular plane is found to be fairly strong. One of the two preferred orientations of the interfacial water molecules present in the neat system is found to disappear in the presence of methanol, because methanol molecules aligned in their preferred orientation can replace these water molecules in the hydrogen-bonding pattern of the interface.

Journal Article↗

Structure of the acetone liquid-vapor interface as seen from Monte Carlo simulations.

The orientational order of the molecules at the liquid-vapor interface of acetone has been investigated by computer simulation. To fully describe the orientational preferences of the acetone molecules, the bivariate joint distribution of two independent orientational parameters has been determined at different layers of the interface. The strength of the orientational ordering of the interfacial molecules has been found to be liquid-like rather than crystal-like. The obtained results have revealed that the interfacial acetone molecules have dual orientational preferences. The main symmetry axis of the molecules declines by about 50-70 degrees from the interface normal axis, pointing toward the liquid phase in both of the preferred orientations. However, the plane of the molecules in the orientation preferred on the liquid side of the interface is perpendicular to the interfacial plane, whereas the other preferred orientation, which is present on the vapor side of the interface, corresponds to the alignment obtained from this orientation by an almost 90 degrees rotation around the main symmetry axis. Because the population of the liquid side is higher than that of the vapor side of the interface, the first of the two preferred orientations is the dominant alignment over the entire interface, in good agreement with recent experimental findings (Chen, H.; Gan, W.; Wu, B. H.; Wu, D.; Zhang, Z.; Wang, H. F. Chem. Phys. Lett. 2005, 408, 284).

Journal Article↗

High-performance liquid chromatographic-tandem mass spectrometric method for the determination of clemastine in human plasma.

A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MS-MS) has been developed to quantitate clemastine in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using deuterated clemastine as an internal standard. Chromatographic separation used a C18 reversed phase polymer column giving an extremely fast total run time of 2 min. The method was validated and used for the bioequivalence study of clemastine tablets in healthy male volunteers (n=28). The lower limit of detection proved to be 0.01 ng/ml for clemastine.

Chromatography, High Pressure Liquid↗

Orientational order of the water molecules at the vicinity of the water-benzene interface in a broad range of thermodynamic states, as seen from Monte Carlo simulations.

Monte Carlo simulation of the water/benzene liquid-liquid interfacial system has been performed at six different thermodynamic state points, ranging from ambient conditions up to the vicinity of the critical point of water. The system has been found to consist of two immiscible liquid phases at every state point studied. The orientational preferences of the interfacial water molecules have been analysed in detail using the simulated configurations. The results obtained at ambient conditions are in agreement with previous results on various different water/apolar interfaces. Thus, interfacial water molecules have been found to have dual orientational preferences: the molecules located nearest to the organic phase prefer to stay perpendicular to the interface, pointing flatly toward the apolar phase by their dipole vectors, whereas the waters located somewhat farther from the organic phase prefer the parallel alignment with the interface. The observed orientational preferences are found to be rather stable with changing thermodynamic conditions: although the increase of the temperature has led, due to the increasing thermal motion of the molecules, to a gradual weakening of the orientational preferences, both preferences are found to exist up to at least 450 K, and found to be completely washed out at 575 K only. The pressure has not been found to influence the orientation of the water molecules noticeably.

Journal Article↗

Binding assays with molecularly imprinted polymers--why do they work?

The design of homologous displacement ligand binding assays based on molecularly imprinted polymers (MIP) is discussed in terms of the MIP adsorption isotherm. It is shown that only MIPs having a binding isotherm with varying slope are suitable for the assay, but there is no need to interpret the isotherm in terms of site affinity and population. One can calculate the calibration plot of the binding assay from the isotherm and vice versa.

Calibration↗

Characterization of the selectivity of a phenytoin imprinted polymer.

The selectivity of analytical methods based on molecularly imprinted polymers (MIPs) is due to the preferential adsorption of the analyte(s) as compared to other substances (interferences). This paper shows the theoretical and practical difficulties, which have to be considered and solved when real samples need to be analysed in a wide range of analyte and interferant concentrations. It is shown that the estimation of interference effects requires either many measurements or a realistic model of the adsorption equilibrium in mixed solutions of the analyte and the interferences. Examples are shown for positive (cooperative) interference effects, for better experimental design and interpretation of binary isotherm measurements and for establishing the chemical model of interference from selectivity measurements. The usual MIP model consisting of a cavity, which closely fits the shape of the template from all sides, appears unsuitable for this MIP, and it is replaced with a more realistic, more open model. The applicability of the results to using non-imprinted polymers as selective sorbents and to screening drug candidates is also shown.

Chromatography↗

Influence of food on the oral bioavailability of deramciclane from film-coated tablet in healthy male volunteers.

The effect of a high-fat meal on the oral bioavailability of deramciclane 30 mg tablet was evaluated in 18 healthy male volunteers in a randomised, single dose, two-way crossover study. The drug was administered following an overnight fast or a standardised high-fat breakfast. The plasma concentrations of deramciclane and N-desmethylderamciclane were determined by using a validated HPLC-MS -MS/MS method. An effect of food on the bioavailability was indicated if the 90% confidence interval (CI) for the ratio of geometric means of fed and fasted treatments was not contained in the equivalence limit of 0.8-1.25 for AUC and C(max). The ratios of the mean C(max) and AUC(0-infinity) values of deramciclane were 1.24 (90% CI 1.12-1.38) and 1.31 (90% CI 1.21-1.41) in fed versus fasted subjects, which overlapped but exceeded the equivalence limit. In contrast to the parent compound, the 90% CI of the mean ratios for AUC(0-infinity) and C(max) of N-desmethylderamciclane were within the predefined range. The 24 and 31% increase in C(max) and AUC(0-infinity) of deramciclane, respectively, under fed condition is modest and probably has no clinical significance since it is relatively small compared to the inter-individual variability of these parameters.

Administration, Oral↗

Effect of solvents on the selectivity of terbutylazine imprinted polymer sorbents used in solid-phase extraction.

A solid-phase extraction sample preparation method using a molecularly imprinted polymer (MIP) selective for the triazine type pesticide terbutylazine has been developed. The method involves preconcentration from large volumes of water samples on a C18 disk coupled to selective clean-up on the MIP. The method has been optimised by studying the recovery and retention of terbutylazine and some other structurally related triazine derivates as a function of the selective washing solvent used. The effect of the water content of the selective washing solvent was also investigated on the recovery of the MIP. River water samples were analysed with the coupled technique, and efficient clean-up of the samples was observed.

Polymers↗