PubMed Health⌕ Search

Biomedical subjects

George K Karavolias

Publications and source records attributed to George K Karavolias.

4 recordsLinked to original sources

Primary stenting of an unprotected left main coronary artery total occlusion in a patient with acute myocardial infraction and cardiogenic shock.

Acute total occlusion of the left main coronary artery (LMCA) is a rare angiographic finding with very poor prognosis. We report a case of a 39-year-old man who presented with pulmonary edema and cardiogenic shock due to an acute anterior myocardial infarction. Coronary angiography, which was performed under the support of an intra-aortic balloon pump, revealed total occlusion of the LMCA. Prompt and successful percutaneous transluminal coronary angioplasty with sirolimus-stent deployment in the LMCA allowed for an uneventful recovery and discharge of the patient.

Adult↗

Repeated exercise stress testing identifies early and late preconditioning.

BACKGROUND: The warm-up phenomenon has been considered to trigger preconditioning. We investigated whether repeated exercise treadmill tests in humans are capable of inducing adaptation to ischemia by triggering both the early and late phase of preconditioning. METHODS: In 25 consecutive patients with stable coronary artery disease, four repeated treadmill tests were performed. Thirty minutes following the first test (T1) a second one was performed (T2), followed 6 h later by a third test (T3). Twenty-four hours later all patients were subjected to a fourth exercise test (T4). In every fifth patient, simultaneous echocardiographic examination was performed at the time of the exercise tests in an attempt to reveal ischemic abnormalities. RESULTS: At baseline there was no difference between the variables. At ST segment depression >1.5 mm, the rate-pressure product (RPP) was higher in T2 and T4 (231.3+/-17.9 and 232.6+/-15.8 mm Hg s 10(2)) than in T1 and T3 (210+/-17 and 210.2+/-16.7 mm Hg s 10(2)), p<0.001. Additionally, time to the onset of chest pain was longer in T2 and T4 (430.8+/-60.5 and 438+/-47 s) than in T1 and T3 (345.6+/-69 and 345.6+/-58 s), p<0.001. At peak exercise, the RPP was higher in T2 and T4 (278.6+/-21.6 and 278.3+/-19.6 mm Hg s 10(2)) than in T1 and T3 (255.6+/-23.1 and 256.6+/-23 mm Hg s 10(2)), p<0.001. The wall motion score index was higher in T1 and T3 (1.65+/-0.17 and 1.53+/-0.16) than in T2 and T4 (1.3+/-0.07 and 1.37+/-0.1), p<0.001. CONCLUSION: By using repeated exercise treadmill tests both the early and late phase of protection can be obtained.

Aged↗

Doppler-derived left ventricular end-diastolic pressure prediction model using the combined analysis of mitral and pulmonary A waves in patients with coronary artery disease and preserved left ventricular systolic function.

The aim of this study was to analyze the components of mitral and pulmonary A waves and to construct a Doppler-derived left ventricular (LV) end-diastolic pressure (EDP) prediction model based on the combined analysis of transmitral and pulmonary venous flow velocity curves. Combined analysis of transmitral and pulmonary venous flow velocity curves at atrial contraction is a reliable predictor of increased LV filling pressure. The duration of pulmonary and mitral A waves is determined by the sum of respective acceleration and deceleration time. Mitral flow and left upper pulmonary vein flow velocity curves were recorded simultaneously with LVEDP in 40 consecutive patients (aged 59 +/- 8 years) with coronary artery disease and preserved LV systolic function. Differences in all parameters represent values of pulmonary minus those of mitral A wave curve. The difference in deceleration time was the strongest candidate, being included in all models. After redundancy evaluation, we reached the following model: LVEDP = 20.61 + 0.229 x difference in deceleration time (r(2) = 0.80, p <0.001). In the entire study group, the difference in duration and in deceleration time of the A wave was highly correlated with LVEDP (r = 0.79, p <0.001, and r = 0.88, p <0.001, respectively). The entire study group was further divided according to whether LVEDP was above (group I, 20 patients) or below (group II, 20 patients) the median value (15.5 mm Hg). In group I, the difference in duration and in deceleration time correlated well (r = 0.62, p = 0.01, and r = 0.75, p = 0.001, respectively) with LVEDP, whereas in group II only the difference in deceleration time correlated well (r = 0.68, p = 0.005). In patients with coronary artery disease and preserved LV systolic function, the combined analysis of mitral and pulmonary A waves can predict LVEDP. The difference in deceleration time between pulmonary and mitral A waves can reliably evaluate high and normal LVEDP.

Blood Flow Velocity↗

Angiotensin II fails to induce preconditioning in vivo--the protective role of myocardial stretch due to pressure overload.

BACKGROUND: Angiotensin II (Ang) has been successfully used as a preconditioning analogue in isolated rabbit hearts. It is also known that local concentrations of Ang accelerate ischemic injury in vivo, while activation of stretch receptors protects ischemic hearts. OBJECTIVES: First, to investigate further whether Ang can mimic preconditioning in vivo. Second, to test the hypothesis that there is an activation of stretch receptors, and that the larger infarct from the left atrium Ang compared with that from the intravenous Ang may be associated with the ischemic injury caused by local administration. METHODS: Male rabbits were divided into four groups - a control group, an ischemic preconditioning group with 5 min ischemia, a left atrial group and an intravenous group with 5 min Ang infusion. All animals were subjected to prolonged ischemia and reperfusion. A second series of experiments was also performed with five groups that had a 5 min mechanical obstruction of the aorta (Ao clamp), also used as a preconditioning analogue with or without the stretch receptor blocker gadolinium (Gd). RESULTS: Contrary to what was expected from the ex vivo experiments, Ang failed to mimic preconditioning (infarct size 39.6 6.1%, 13.7 4.1%, 52.2% 6.9% and 31.2 4.8%, respectively for the above groups). Interestingly, however, when Ang was infused intravenously, it produced a significantly smaller infarct compared with that observed after the same dose was infused into the left atrium (P<0.05). The infarct size was 17.0 3.7% in the Ao clamp group, which was an effect completely prevented by Gd (45.8 4.2%, P<0.01). Although Gd did not alter infarct size in the control and ischemic preconditioning groups, it increased infarct size when added to the intravenous Ang group (Gd-intravenous Ang 48.6 3.3%, P<0.05 compared with intravenous Ang). CONCLUSIONS: Ang fails to mimic preconditioning in vivo, but salvage of ischemic myocardium can be emanated from pressure overload.

Angiotensin II↗