Design of 4D treatment planning target volumes.

PURPOSE: When using non-patient-specific treatment planning margins, respiratory motion may lead to geometric miss of the target while unnecessarily irradiating normal tissue. Imaging different respiratory states of a patient allows patient-specific target design. We used four-dimensional computed tomography (4DCT) to characterize tumor motion and create treatment volumes in 10 patients with lung cancer. These were compared with standard treatment volumes. METHODS AND MATERIALS: Four-dimensional CT and free breathing helical CT data of 10 patients were acquired. Gross target volumes (GTV) were delineated on the helical scan as well as on each phase of the 4D data. Composite GTVs were defined on 4DCT. Planning target volumes (PTV) including clinical target volume, internal margin (IM), and setup margin were generated. 4DPTVs with different IMs and standard PTVs were compared by computing centroid positions, volumes, volumetric overlap, and bounding boxes. RESULTS: Four-dimensional PTVs and conventional PTVs differed in volume and centroid positions. Overlap between 4DPTVs generated from two extreme tumor positions only compared with 10 respiratory phases was 93.7%. Comparing PTVs with margins of 15 mm (IM 5 mm) on composite 4D target volumes to PTVs with 20 mm (IM 10 mm) on helical CT data resulted in a decrease in target volume sizes by 23% on average. CONCLUSION: With patient-specific characterization of tumor motion, it should be possible to decrease internal margins. Patient-specific treatment volumes can be generated using extreme tumor positions on 4DCT. To date, more than 150 patients have been treated using 4D target design.

Carcinoma, Non-Small-Cell Lung↗

Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients.

PURPOSE: To assess the utility of surface imaging on patient setup for accelerated partial-breast irradiation (APBI). METHODS AND MATERIAL: A photogrammetry system was used in parallel to APBI setup by laser and portal imaging. Surface data were acquired after laser and port-film setup for 9 patients. Surfaces were analyzed in comparison to a reference surface from the first treatment session by use of rigid transformations. The surface model after laser setup was used in a simulated photogrammetry setup procedure. In addition, breathing data were acquired by surface acquisition at a frame rate of 7 Hz. RESULTS: Mean 3D displacement was 7.3 mm (SD, 4.4 mm) and 7.6 mm (SD, 4.2 mm) for laser and port film, respectively. Simulated setup with the photogrammetry system yielded mean displacement of 1 mm (SD, 1.2 mm). Distance analysis resulted in mean distances of 3.7 mm (SD, 4.9 mm), 4.3 mm (SD, 5.6 mm), and 1.6 mm (SD, 2.4 mm) for laser, port film, and photogrammetry, respectively. Breathing motion at isocenter was smaller than 3.7 mm, with a mean of 1.9 mm (SD, 1.1 mm). CONCLUSIONS: Surface imaging for PBI setup appears promising. Alignment of the 3D breast surface achieved by stereo-photogrammetry shows greater breast topology congruence than when patients are set up by laser or portal imaging. A correlation of breast surface and CTV must be quantitatively established.

Breast Neoplasms↗

Image interpolation in 4D CT using a BSpline deformable registration model.

PURPOSE: To develop a method for deriving the phase-binned four-dimensional computed tomography (4D CT) image sets through interpolation of the images acquired at some known phases. METHODS AND MATERIALS: Four-dimensional computed tomography data sets for 3 patients were acquired. For each patient, the correlation between inhale and exhale phases was studied and quantified using a BSpline deformable model. Images at an arbitrary phase were deduced by an interpolation of the deformation coefficients. The accuracy of the proposed scheme was assessed by comparing marker trajectories and by checkerboard/difference display of the interpolated and acquired images. RESULTS: The images at intermediate phases could be derived by an interpolation of the deformation field. An analysis of marker movements indicated that 3 mm accuracy is achievable by the interpolation. The subtraction of image analysis indicated a similar level of success. The proposed technique was useful also for automatically mapping the organ contours in a known phase to other phases, and for designing patient-specific margins in the presence of respiratory motion. Finally, the technique led to a 90% reduction in the acquired data, because in the BSpline model, a lattice of only a few thousand values is sufficient to describe a CT data set of 25 million pixels. CONCLUSIONS: Organ deformation can be well modeled by using a BSpline model. The proposed technique may offer useful means for radiation dose reduction, binning artifacts removal, and disk storage improvement in 4D imaging.

Algorithms↗

Improving retrospective sorting of 4D computed tomography data.

Respiratory correlated CT is commercially available, and we have implemented its routine clinical use in planning lung tumor patients. Its value is determined by the fidelity of the spatiotemporal data set after processing the acquired reconstructed slices. Retrospective sorting of reconstructed slices is based on respiratory phase. However, the existing commercial software inadequately models respiratory phase for about 30% of the patients, mainly due to irregularities in the respiratory cycle. We have developed software that improves phase determination and consequently leads to an improvement of retrospective data sorting to make 4DCT data acquisition feasible for routine clinical use. Peak inhalation and exhalation respiratory states are selected manually; intermediate phases are interpolated. Residual motion artifacts in the resulting 4DCT volumes are reduced and allow use of the 4D imaging studies for treatment planning.

Algorithms↗

The susceptibility of IMRT dose distributions to intrafraction organ motion: an investigation into smoothing filters derived from four dimensional computed tomography data.

This study investigated the sensitivity of static planning of intensity-modulated beams (IMBs) to intrafraction deformable organ motion and assessed whether smoothing of the IMBs at the treatment-planning stage can reduce this sensitivity. The study was performed with a 4D computed tomography (CT) data set for an IMRT treatment of a patient with liver cancer. Fluence profiles obtained from inverse-planning calculations on a standard reference CT scan were redelivered on a CT scan from the 4D data set at a different part of the breathing cycle. The use of a nonrigid registration model on the 4D data set additionally enabled detailed analysis of the overall intrafraction motion effects on the IMRT delivery during free breathing. Smoothing filters were then applied to the beam profiles within the optimization process to investigate whether this could reduce the sensitivity of IMBs to intrafraction organ motion. In addition, optimal fluence profiles from calculations on each individual phase of the breathing cycle were averaged to mimic the convolution of a static dose distribution with a motion probability kernel and assess its usefulness. Results from nonrigid registrations of the CT scan data showed a maximum liver motion of 7 mm in superior-inferior direction for this patient. Dose-volume histogram (DVH) comparison indicated a systematic shift when planning treatment on a motion-frozen, standard CT scan but delivering over a full breathing cycle. The ratio of the dose to 50% of the normal liver to 50% of the planning target volume (PTV) changed up to 28% between different phases. Smoothing beam profiles with a median-window filter did not overcome the substantial shift in dose due to a difference in breathing phase between planning and delivery of treatment. Averaging of optimal beam profiles at different phases of the breathing cycle mainly resulted in an increase in dose to the organs at risk (OAR) and did not seem beneficial to compensate for organ motion compared with using a large margin. Additionally, the results emphasized the need for 4D CT scans when aiming to reduce the internal margin (IM). Using only a single planning scan introduces a systematic shift in the dose distribution during delivery. Smoothing beam profiles either based on a single scan or over the different breathing phases was not beneficial for reducing this shift.

Body Burden↗

Deformable registration of 4D computed tomography data.

Four-dimensional radiotherapy requires deformable registration to track delivered dose across varying anatomical states. Deformable registration based on B-splines was implemented to register 4D computed tomography data to a reference respiratory phase. To assess registration performance, anatomical landmarks were selected across ten respiratory phases in five patients. These point landmarks were transformed according to global registration parameters between different respiratory phases. Registration uncertainties were computed by subtraction of transformed and reference landmark positions. The selection of appropriate registration masks to separate independently moving anatomical subunits is crucial to registration performance. The average registration error for five landmarks for each of five patients was 2.1 mm. This level of accuracy is acceptable for most radiotherapy applications.

Aged↗

Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates.

Due to respiration, many tumours in the thorax and abdomen may move as much as 3 cm peak-to-peak during radiation treatment. To mitigate motion-induced irradiation of normal lung tissue, clinics have employed external markers to gate the treatment beam. This technique assumes that the correlation between the external surface and the internal tumour position remains constant inter-fractionally and intra-fractionally. In this work, a study has been performed to assess the validity of this correlation assumption for external surface based gated radiotherapy, by measuring the residual tumour motion within a gating window. Eight lung patients with implanted fiducial markers were studied at the NTT Hospital in Sapporo, Japan. Synchronized internal marker positions and external abdominal surface positions were measured during the entire course of treatment. Stereoscopic imaging was used to find the internal markers in four dimensions. The data were used retrospectively to assess conventional external surrogate respiratory-gated treatment. Both amplitude- and phase-based gating methods were investigated. For each method, three gating windows were investigated, each giving 40%, 30% and 20% duty cycle, respectively. The residual motion of the internal marker within these six gating windows was calculated. The beam-to-beam variation and day-to-day variation in the residual motion were calculated for both gating modalities. We found that the residual motion (95th percentile) was between 0.7 and 5.8 mm, 0.8 and 6.0 mm, and 0.9 and 6.2 mm for 20%, 30% and 40% duty cycle windows, respectively. Five of the eight patients showed less residual motion with amplitude-based gating than with phase-based gating. Large fluctuations (>300%) were seen in the residual motion between some beams. Overall, the mean beam-to-beam variation was 37% and 42% from the previous treatment beam for amplitude- and phase-based gating, respectively. The day-to-day variation was 29% and 34% from the previous day for amplitude- and phase-based gating, respectively. Although gating reduced the total tumour motion, the residual motion behaved unpredictably. Residual motion during treatment could exceed that which might have been considered in the treatment plan. Treatment margins that account for motion should be individualized and daily imaging should be performed to ensure that the residual motion is not exceeding the planned motion on a given day.

Dose-Response Relationship, Radiation↗

A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode.

Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this technique. The markers are contoured on the planning CT set, enabling us to create digitally reconstructed radiographs (DRRs) for each treatment beam. During the treatment, a sequence of EPID images can be acquired without disrupting the treatment. Implanted markers are visualized in the images and their positions in the beam's eye view are calculated off-line and compared to the reference position by matching the field apertures in corresponding EPID and DRR images. The precision of the patient set-up, the placement of the beam-gating window, as well as the residual tumour motion can be assessed for each treatment fraction. This technique has been demonstrated with a case study patient, who had three markers implanted in his liver. For this patient, the intra-fractional variation of all marker positions in the gating window had a 95% range of 4.8 mm in the SI direction (the primary axis of motion). This was about the same (5 mm) as the residual motion considered in the planning process. The inter-fractional variation of the daily mean positions of the markers, which indicates the uncertainty in the set-up procedure, was within +8.3 mm/-4.5 mm (95% range) in the SI direction for this case.

Aged↗

Temporo-spatial IMRT optimization: concepts, implementation and initial results.

With the recent availability of 4D-CT, the accuracy of information on internal organ motion during respiration has improved significantly. We investigate the utility of organ motion information in IMRT treatment planning, using an in-house prototype optimization system. Four approaches are compared: (1) planning with optimized margins, based on motion information; (2) the 'motion kernel' approach, in which a more accurate description of the dose deposit from a pencil beam to a moving target is achieved either through time-weighted averaging of influence matrices, calculated for different instances of anatomy (subsets of 4D-CT data, corresponding to various phases of motion) or through convolution of the pencil beam kernel with the probability density function describing the target motion; (3) optimal gating, or tracking with beam intensity maps optimized independently for each instance of anatomy; and (4) optimal tracking with beam intensity maps optimized simultaneously for all instances of anatomy. The optimization is based on a gradient technique and can handle both physical (dose-volume) and equivalent uniform dose constraints. Optimization requires voxel mapping from phase to phase in order to score the dose in individual voxels as they move. The results show that, compared to the other approaches, margin expansion has a significant disadvantage by substantially increasing the integral dose to patient. While gating or tracking result in the best dose conformation to the target, the former elongates treatment time, and the latter significantly complicates the delivery procedure. The 'motion kernel' approach does not provide a dosimetric advantage, compared to optimal tracking or gating, but might lead to more efficient delivery. A combination of gating with the 'motion kernel' or margin expansion approach will increase the duty cycle and may provide one with the most efficient solution, in terms of complexity of the delivery procedure and dose conformality to the target.

Algorithms↗

Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion.

PURPOSE: To describe approaches to four-dimensional (4D) treatment planning, including acquisition of 4D-CT scans, target delineation of spatio-temporal image data sets, 4D dose calculations, and their analysis. METHODS AND MATERIALS: The study included patients with thoracic and hepatocellular tumors. Specialized tools were developed to facilitate visualization, segmentation, and analysis of 4D-CT data: maximum intensity volume to define the extent of lung tumor motion, a 4D browser to examine and dynamically assess the 4D data sets, dose calculations, including respiratory motion, and deformable registration to combine the dose distributions at different points. RESULTS: Four-dimensional CT was used to visualize and quantitatively assess respiratory target motion. The gross target volume contours derived from light breathing scans showed significant differences compared with those extracted from 4D-CT. Evaluation of deformable registration using difference images of original and deformed anatomic maps suggested the algorithm is functionally useful. Thus, calculation of effective dose distributions, including respiratory motion, was implemented. CONCLUSION: Tools and methods to use 4D-CT data for treatment planning in the presence of respiratory motion have been developed and applied to several case studies. The process of 4D-CT-based treatment planning has been implemented, and technical barriers for its routine use have been identified.

Algorithms↗

The correlation between internal and external markers for abdominal tumors: implications for respiratory gating.

PURPOSE: The correlation of the respiratory motion of external patient markers and abdominal tumors was examined. Data of this type are important for image-guided therapy techniques, such as respiratory gating, that monitor the movement of external fiducials. METHODS AND MATERIALS: Fluoroscopy sessions for 4 patients with internal, radiopaque tumor fiducial clips were analyzed by computer vision techniques. The motion of the internal clips and the external markers placed on the patient's abdominal skin surface were quantified and correlated. RESULTS: In general, the motion of the tumor and external markers were well correlated. The maximum amount of peak-to-peak craniocaudal tumor motion was 2.5 cm. The ratio of tumor motion to external-marker motion ranged from 0.85 to 7.1. The variation in tumor position for a given external-marker position ranged from 2 to 9 mm. The period of the breathing cycle ranged from 2.7 to 4.5 seconds, and the frequency patterns for both the tumor and the external markers were similar. CONCLUSIONS: Although tumor motion generally correlated well with external fiducial marker motion, relatively large underlying tumor motion can occur compared with external-marker motion and variations in the tumor position for a given marker position. Treatment margins should be determined on the basis of a detailed understanding of tumor motion, as opposed to relying only on external-marker information.

Abdominal Neoplasms↗

Model-based segmentation of medical imagery by matching distributions.

The segmentation of deformable objects from three-dimensional (3-D) images is an important and challenging problem, especially in the context of medical imagery. We present a new segmentation algorithm based on matching probability distributions of photometric variables that incorporates learned shape and appearance models for the objects of interest. The main innovation over similar approaches is that there is no need to compute a pixelwise correspondence between the model and the image. This allows for a fast, principled algorithm. We present promising results on difficult imagery for 3-D computed tomography images of the male pelvis for the purpose of image-guided radiotherapy of the prostate.

Algorithms↗

Four-dimensional computed tomography: image formation and clinical protocol.

Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning and delivery, time-resolved CT data acquisition (4D Computed Tomography) is needed. 4DCT can be accomplished by oversampled CT data acquisition at each slice. During several CT tube rotations projection data are collected in axial cine mode for the duration of the patient's respiratory cycle (plus the time needed for a full CT gantry rotation). Multiple images are then reconstructed per slice that are evenly distributed over the acquisition time. Each of these images represents a different anatomical state during a respiratory cycle. After data acquisition at one couch position is completed, x rays are turned off and the couch advances to begin data acquisition again until full coverage of the scan length has been obtained. Concurrent to CT data acquisition the patient's abdominal surface motion is recorded in precise temporal correlation. To obtain CT volumes at different respiratory states, reconstructed images are sorted into different spatio-temporally coherent volumes based on respiratory phase as obtained from the patient's surface motion. During binning, phase tolerances are chosen to obtain complete volumetric information since images at different couch positions are reconstructed at different respiratory phases. We describe 4DCT image formation and associated experiments that characterize the properties of 4DCT. Residual motion artifacts remain due to partial projection effects. Temporal coherence within resorted 4DCT volumes is dominated by the number of reconstructed images per slice. The more images are reconstructed, the smaller phase tolerances can be for retrospective sorting. From phantom studies a precision of about 2.5 mm for quasiregular motion and typical respiratory periods could be concluded. A protocol for 4DCT scanning was evaluated and clinically implemented at the MGH. Patient data are presented to elucidate how additional patient specific parameters can impact 4DCT imaging.

Algorithms↗

A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup.

External beam irradiation requires precise positioning of the target relative to the treatment planning coordinate system. A three-dimensional (3D) surface imaging system for patient positioning has recently been installed in one of our linear accelerator (linac) rooms. The device utilizes close-range photogrammetry to generate a 3D model of the patient's surface. This geometric model can be made to look like a digital camera image if wrapped with a gray-level image (texture mapping) that shows surface coloration. The system is calibrated to the linac coordinate system and has been designed as a patient setup device. To reproduce patient position in fractionated radiotherapy, the daily patient surface model is registered to a previously recorded reference surface. Using surface registration, the system calculates the rigid-body transformation that minimizes the distance between the treatment and the reference surface models in a region-of-interest (ROI). This transformation is expressed as a set of new couch coordinates at which the patient position best matches with the reference data. If respiratory motion is a concern, the surface can be obtained with a gated acquisition at a specified phase of the respiratory cycle. To analyze the accuracy of the system, we performed several experiments with phantoms to assess stability, alignment accuracy, precision of the gating function, and surface topology. The reproducibility of surface measurements was tested for periods up to 57 h. Each recorded frame was registered to the reference surface to calculate the required couch adjustment. The system stability over this time period was better than 0.5 mm. To measure the accuracy of the system to detect and quantify patient shift relative to a reference image, we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The maximum standard deviation was 0.75 mm for the three translational degrees of freedom, and less than 0.1 degrees for each rotation. Surface model precision was tested against computed tomography (CT)-derived surface topology. The root-mean-square rms of the distance between the surfaces was 0.65 mm, excluding regions where beam hardening caused artifacts in the CT data. Measurements were made to test the gated acquisition mode. The time-dependent amplitude was measured with the surface imaging system and an established respiratory gating system based on infrared (IR)-marker detection. The measured motion trajectories from both systems were compared to the known trajectory of the stage. The standard deviations of the amplitude differences to the motor trajectory were 0.04 and 0.15 mm for the IR-marker system and the 3D surface imaging system, respectively. A limitation of the surface-imaging device is the frame rate of 6.5 Hz, because rapid changes of the motion trajectory cannot be detected. In conclusion, the system is accurate and sufficiently stable to be used in the clinic. The errors computed when comparing the surface model with CT geometry were submillimeter, and deviations in the alignment and gating-signal tests were of the same magnitude.

Humans↗

Permanent alopecia after cranial irradiation: dose-response relationship.

PURPOSE: To develop a dose-response relationship for the occurrence of permanent alopecia after cranial irradiation and to analyze potential confounding variables that may contribute to this unwanted and often unavoidable complication of treatment. METHODS AND MATERIALS: Twenty-six patients were enrolled in this study. Three reviewers independently assessed 61 scalp regions and assigned a score for the degree of alopecia in each region using a 4-point scale. Patient and treatment data were collected using a patient questionnaire and outpatient medical chart review. The hair follicle dose was calculated for each scalp region and correlated with the alopecia score for that region. A dose-response relationship was established using the data from these correlations. RESULTS: Permanent alopecia correlated significantly with the follicle dose only (p < 0.001). A personal history of alopecia and the use of chemotherapy correlated with permanent alopecia with borderline statistical significance (p = 0.059 and p = 0.068, respectively). Patient age, family history of baldness, gender, tobacco use, diabetes, and beam energy did not correlate with alopecia. CONCLUSION: We report the first human dose-response relationship describing the effect of the follicle dose on the subsequent development of permanent scalp alopecia after cranial irradiation. This information will assist the radiation oncologist, physicist, and dosimetrist in designing a treatment plan that might minimize the risk of this untoward side effect of cranial irradiation.

Adult↗

Quantification of respiration-induced abdominal tumor motion and its impact on IMRT dose distributions.

PURPOSE: The treatment of moving targets with intensity-modulated radiotherapy may introduce errors in dose delivery. The motion of tumors in the abdomen was studied using quantitative fluoroscopic analysis, and the effect on dose delivery to the target was studied. METHODS AND MATERIALS: Fluoroscopy sessions for 7 patients with pancreas or liver tumors and fiducial clips were recorded, converted to digital format, and analyzed to quantify the characteristics of tumor motion. Intensity-modulated radiotherapy plans were generated for 3 patients (a total of five plans), and the dose-volume histograms for the target volume were compared between plans with and without tumor motion. RESULTS: The average magnitude of the peak-to-peak motion for the 7 patients in the craniocaudal and AP directions was 7.4 mm and 3.8 mm, respectively. The clip motion varied widely, because the maximal clip excursions were about 47% greater than the average clip excursions for each patient. The inclusion of tumor motion did not lead to a significant degradation in the target dose-volume histogram for four of five treatment plans studied. CONCLUSION: The amount of tumor motion for most patients in this study was not large but could, in some instances, significantly degrade the planned target dose-volume histogram. For some patients, therefore, motion mitigation or intervention during treatment may be necessary.

Cholangiocarcinoma↗

Moving targets: detection and tracking of internal organ motion for treatment planning and patient set-up.

BACKGROUND AND PURPOSE: Clinical target volumes of the thorax and abdomen are typically expanded to account for inter- and intrafractional organ motion. Usually, such expansions are based on clinical experience and planar observations of target motion during simulation. More precise, 4-dimensional motion margins for a specific patient may improve dose coverage of mobile targets and yet limit unnecessarily large field expansions. We are studying approaches to targeting moving tumors throughout the entire treatment process, from treatment planning to beam delivery. MATERIAL AND METHODS: Radio-opaque markers were implanted under CT guidance in the liver at the gross tumor periphery. Organ motion during light respiration was volumetrically imaged by 4D Computed Tomography. Marker motion was also acquired by fluoroscopy and compared with 4DCT data. During treatment, daily diagnostic x-ray images were captured at end-exhale and -inhale for patient setup and target localization. RESULTS: Based on the time-resolved CT data, target volumes can be designed to account for respiratory motion during treatment. Motion of the tumor as derived from 4DCT was consistent with fluoroscopic motion analysis. Radiographs acquired in the treatment room enabled millimeter-level patient set-up and assessment of target position relative to bony anatomy. Daily positional variations between bony anatomy and implanted markers were observed. CONCLUSIONS: Image guided therapy, based on 4DCT imaging, fluoroscopic imaging studies, and daily gated diagonstic energy set-up radiographs is being developed to improve beam delivery precision. Monitoring internal target motion throughout the entire treatment process will ensure adequate dose coverage of the target while sparing the maximum healthy tissue.

Humans↗

Artifacts in computed tomography scanning of moving objects.

Target volumes in the thorax and abdomen are commonly computed tomography (CT) scanned during light respiration. In this article, we analyze the distortions introduced in helical scanning of moving objects. Objects of known geometry are placed on a moving sled and scanned in a multirow helical CT scanner. The motion of the sled approximates the magnitude and velocity of organ movement in patients during light respiration (amplitude 1 cm, period 4 seconds). Scans of the phantom are obtained in high speed mode at incremental phases of respiration, and the resulting images are compared with scans obtained when the phantom is static. Computer simulations of the scan process are also performed to interpret the results and extend the analysis to a greater range of parameters in scanning, motion, and object size. Resulting scans show that spherical test objects can be shortened by as much as 2 cm or twice the periodic motion amplitude. Object shape was significantly distorted, and the geometric center of the object was displaced by as much as +/-0.8 cm. Computer simulation results qualitatively agree with the experimentally observed phantom images. These simulations predict that the effect is clearly observable even if the amplitude is decreased to 0.5 cm. Implications of scanning moving objects on treatment planning are discussed.

Artifacts↗