George X Ding

Publications and source records attributed to George X Ding.

9 recordsLinked to original sources

Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: initial experience.

We report our initial experience with deep-inspiration breath-hold (DIBH) cone-beam CT (CBCT) on the treatment table, using the kilovoltage imager integrated into our linear accelerator, for setting up patients for DIBH stereotactic body radiation therapy (SBRT) for lung tumors. Nine patients with non-small cell lung cancer (seven stage I), were given 60Gy in three fractions. All nine patients could perform a DIBH for 35s. For each patient we used a diagnostic reference CT volume image acquired during a DIBH to design an SBRT plan consisting of 7-10 noncoplanar conformal beams. Four patients were setup by registering DIBH kilovoltage projection radiographs or megavoltage portal images on the treatment table to digitally reconstructed radiographs from the reference CT. Each of the last 14 fractions out of a total of 27 was setup by acquiring a CBCT volume image on the treatment table in three breath-holds. The CBCT and reference CT volume images were directly registered and the shift was calculated from the registration. The CBCT volume images contained excellent detail on soft tissue and bony anatomy for matching to the reference CT. Most importantly, the tumor was always clearly visible in the CBCT images, even when it was difficult or impossible to see in the radiographs or portal images. The accuracy of the CBCT method was confirmed by DIBH megavoltage portal imaging and each treatment beam was delivered during a DIBH. CBCT acquisition typically required five more minutes than radiograph acquisition but the overall setup time was often shorter using CBCT because repeat imaging was minimized. We conclude that for setting up SBRT treatments of lung tumors, DIBH CBCT is feasible, fast and may result in less variation among observers than using bony anatomy in orthogonal radiographs.

Aged↗

First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning--new issues for clinical consideration.

The purpose of this study is to present our experience of commissioning, testing and use of the first commercial macro Monte Carlo based dose calculation algorithm for electron beam treatment planning and to investigate new issues regarding dose reporting (dose-to-water versus dose-to-medium) as well as statistical uncertainties for the calculations arising when Monte Carlo based systems are used in patient dose calculations. All phantoms studied were obtained by CT scan. The calculated dose distributions and monitor units were validated against measurements with film and ionization chambers in phantoms containing two-dimensional (2D) and three-dimensional (3D) type low- and high-density inhomogeneities at different source-to-surface distances. Beam energies ranged from 6 to 18 MeV. New required experimental input data for commissioning are presented. The result of validation shows an excellent agreement between calculated and measured dose distributions. The calculated monitor units were within 2% of measured values except in the case of a 6 MeV beam and small cutout fields at extended SSDs (>110 cm). The investigation on the new issue of dose reporting demonstrates the differences up to 4% for lung and 12% for bone when 'dose-to-medium' is calculated and reported instead of 'dose-to-water' as done in a conventional system. The accuracy of the Monte Carlo calculation is shown to be clinically acceptable even for very complex 3D-type inhomogeneities. As Monte Carlo based treatment planning systems begin to enter clinical practice, new issues, such as dose reporting and statistical variations, may be clinically significant. Therefore it is imperative that a consistent approach to dose reporting is used.

Algorithms↗

Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.

The purpose of this investigation is to study the feasibility of using an alternative method to commission stereotactic radiosurgery beams shaped by micro multi-leaf collimators by using Monte Carlo simulations to obtain beam characteristics of small photon beams, such as incident beam particle fluence and energy distributions, scatter ratios, depth-dose curves and dose profiles where measurements are impossible or difficult. Ionization chambers and diode detectors with different sensitive volumes were used in the measurements in a water phantom and the Monte Carlo codes BEAMnrc/DOSXYZnrc were used in the simulation. The Monte Carlo calculated data were benchmarked against measured data for photon beams with energies of 6 MV and 10 MV produced from a Varian Trilogy accelerator. The measured scatter ratios and cross-beam dose profiles for very small fields are shown to be not only dependent on the size of the sensitive volume of the detector used but also on the type of detectors. It is known that the response of some detectors changes at small field sizes. Excellent agreement was seen between scatter ratios measured with a small ion chamber and those calculated from Monte Carlo simulations. The values of scatter ratios, for field sizes from 6 x 6 mm2 to 98 x 98 mm2, range from 0.67 to 1.0 and from 0.59 to 1.0 for 6 and 10 MV, respectively. The Monte Carlo calculations predicted that the incident beam particle fluence is strongly affected by the X-Y-jaw openings, especially for small fields due to the finite size of the radiation source. Our measurement confirmed this prediction. This study demonstrates that Monte Carlo calculations not only provide accurate dose distributions for small fields where measurements are difficult but also provide additional beam characteristics that cannot be obtained from experimental methods. Detailed beam characteristics such as incident photon fluence distribution, energy spectra, including composition of primary and scattered photons, can be independently used in dose calculation models and to improve the accuracy of measurements with detectors with an energy-dependent response. Furthermore, when there are discrepancies between results measured with different detectors, the Monte Carlo calculated values can indicate the most correct result. The data set presented in this study can be used as a reference in commissioning stereotactic radiosurgery beams shaped by a BrainLAB m3 on a Varian 2100EX or 600C accelerator.

Body Burden↗

A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm.

PURPOSE: To present a comparison of the accuracy of two commercial electron beam treatment planning systems: one uses a Monte Carlo algorithm and the other uses a pencil beam model for dose calculations. METHODS AND MATERIALS: For the same inhomogeneous phantoms and incident beams, measured dose distributions are compared with those predicted by the commercial treatment planning systems at different source-to-surface distances (SSDs). The accuracy of the pencil beam system for monitor unit calculations is also tested at various SSDs. Beam energies of 6-20 MeV are used. RESULTS: The pencil beam model shows some serious limitations in predicting hot and cold spots in inhomogeneous phantoms for small low- or high-density inhomogeneities, especially for low-energy electron beams, such as 9 MeV. Errors (>10%) are seen in predicting high- and low-dose variations for three-dimensional inhomogeneous phantoms. The Monte Carlo calculated results generally agree much better with measurements. CONCLUSIONS: The accuracy of the pencil beam calculations is difficult to predict because it depends on both the inhomogeneity geometry and location. The pencil beam calculations using CADPLAN result in large errors in phantoms containing three-dimensional type inhomogeneities. The Monte Carlo method in Theraplan Plus dose calculation module is shown to be more robust in accurately predicting dose distributions and monitor units under the tested conditions.

Air↗

An investigation of accelerator head scatter and output factor in air.

Our purpose in this study was to investigate whether the Monte Carlo simulation can accurately predict output factors in air. Secondary goals were to study the head scatter components and investigate the collimator exchange effect. The Monte Carlo code, BEAMnrc, was used in the study. Photon beams of 6 and 18 MV were from a Varian Clinac 2100EX accelerator and the measurements were performed using an ionization chamber in a mini-phantom. The Monte Carlo calculated in air output factors was within 1% of measured values. The simulation provided information of the origin and the magnitude of the collimator exchange effect. It was shown that the collimator backscatter to the beam monitor chamber played a significant role in the beam output factors. However the magnitude of the scattered dose contributions from the collimator at the isocenter is negligible. The maximum scattered dose contribution from the collimators was about 0.15% and 0.4% of the total dose at the isocenter for a 6 and 18 MV beam, respectively. The scattered dose contributions from the flattening filter at the isocenter were about 0.9-3% and 0.2-6% of the total dose for field sizes of 4x4 cm2-40x40 cm2 for the 6 and 18 MV beam, respectively. The study suggests that measurements of head scatter factors be done at large depth well beyond the depth of electron contamination. The insight information may have some implications for developing generalized empirical models to calculate the head scatter.

Air↗

Using Monte Carlo simulations to commission photon beam output factors--a feasibility study.

This study investigates the feasibility of using Monte Carlo methods to assist the commissioning of photon beam output factors from a medical accelerator. The Monte Carlo code, BEAMnrc, was used to model 6 MV and 18 MV photon beams from a Varian linear accelerator. When excellent agreements were obtained between the Monte Carlo simulated and measured dose distributions in a water phantom, the entire geometry including the accelerator head and the water phantom was simulated to calculate the relative output factors. Simulated output factors were compared with measured data, which consist of a typical commission dataset for the output factors. The measurements were done using an ionization chamber in a water phantom at a depth of 10 cm with a source-detector distance of 100 cm. Square fields and rectangular fields with widths and lengths ranging from 4 cm to 40 cm were studied. The result shows a very good agreement (< 1.5%) between the Monte Carlo calculated and the measured relative output factors for a typical commissioning dataset. The Monte Carlo calculated backscatter factors to the beam monitor chamber agree well with measured data in the literature. Monte Carlo simulations have also been shown to be able to accurately predict the collimator exchange effect and its component for rectangular fields. The information obtained is also useful to develop an algorithm for accurate beam modelling. This investigation indicates that Monte Carlo methods can be used to assist commissioning of output factors for photon beams.

Calibration↗

Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?

This study presents measured neutron dose using a neutron dosimeter in a water phantom and investigates a hypothesis that neutrons in a high-energy photon beam may be responsible for the reported significant dose discrepancies between Monte Carlo calculations and measurements at the build-up region in large fields. Borated polyethylene slabs were inserted between the accelerator head and the phantom in order to remove neutrons generated in the accelerator head. The thickness of the slab ranged from 2.5 cm to 10 cm. A lead slab of 3 mm thickness was also used in the study. The superheated drop neutron dosimeter was used to measure the depth-dose curve of neutrons in a high-energy photon beam and to verify the effectiveness of the slab to remove these neutrons. Total dose measurements were performed in water using a WELLHOFER WP700 beam scanner with an IC-10 ionization chamber. The Monte Carlo code BEAM was used to simulate an 18 MV photon beam from a Varian Clinac-2100EX accelerator. Both EGS4/DOSXYZ and EGSnrc/DOSRZnrc were used in the dose calculations. Measured neutron dose equivalents as a function of depth per unit total dose in water were presented for 10 x 10 and 40 x 40 cm2 fields. The measured results have shown that a 5-10 cm thick borated polyethylene slab can reduce the neutron dose by a factor of 2 when inserted between the accelerator head and the detector. In all cases the measured neutron dose equivalent was less than 0.5% of the photon dose. In order to study if the ion chamber was highly sensitive to the neutron dose, we have investigated the disagreement between the Monte Carlo calculated and measured central-axis depth-dose curves in the build-up region when different shielding materials were used. The result indicated that the IC-10 chamber was not highly sensitive to the neutron dose. Therefore, neutrons present in a high-energy photon beam were unlikely to be responsible for the reported discrepancies in the build-up region for large fields.

Artifacts↗

Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of monte carlo simulations for a varian 2100EX accelerator.

The purpose of this study is to provide detailed characteristics of incident photon beams for different field sizes and beam energies. This information is critical to the future development of accurate treatment planning systems. It also enhances our knowledge of radiotherapy photon beams. The EGS4 Monte Carlo code, BEAM, has been used to simulate 6 and 18 MV photon beams from a Varian Clinac-2100EX accelerator. A simulated realistic beam is stored in a phase space data file, which contains details of each particle's complete history including where it has been and where it has interacted. The phase space files are analysed to obtain energy spectra, angular distribution, fluence profile and mean energy profiles at the phantom surface for particles separated according to their charge and history. The accuracy of a simulated beam is validated by the excellent agreement between the Monte Carlo calculated and measured dose distributions. Measured depth-dose curves are obtained from depth-ionization curves by accounting for newly introduced chamber fluence corrections and the stopping-power ratios for realistic beams. The study presents calculated depth-dose components from different particles as well as calculated surface dose and contribution from different particles to surface dose across the field. It is shown that the increase of surface dose with the increase of the field size is mainly due to the increase of incident contaminant charged particles. At 6 MV, the incident charged particles contribute 7% to 21% of maximum dose at the surface when the field size increases from 10 x 10 to 40 x 40 cm2. At 18 MV, their contributions are up to 11% and 29% of maximum dose at the surface for 10 x 10 cm2 and 40 x 40 cm2 fields respectively. However, the fluence of these incident charged particles is less than 1% of incident photon fluence in all cases.

Electrons↗

Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam.

This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source of electrons in the accelerator head that was not fully accounted for in the treatment head simulation. In this investigation, a lead foil is added just below the accelerator head in order to study this hypothesis. The lead foil effectively removes charged particles generated inside the accelerator head. The charged particles generated by the lead foil can be accounted for fully because the simple geometry can be simulated accurately. An 18 MV photon beam from a Varian Clinac-2100EX is measured using a WELLHOFER WP700 beam scanner with an IC-10 ionization chamber (cavity radius=3 mm). The BEAM Monte Carlo code is used in the incident beam simulations. Both EGS4/DOSXYZ and EGSnrc/DOSRZnrc are used in the dose calculations in a water phantom. The Monte Carlo calculated depth-dose curve is scaled so that it has the same values at 10 cm depth as the measured curve. It is found that the discrepancies between Monte Carlo calculations and measurements remain significant in the buildup region even after applying necessary corrections to the measured data. The discrepancies have only been modestly decreased with the lead foil in place compared to the 40 x 40 cm2 open field. At a depth of 1 cm, discrepancies of about 5% are still observed in the buildup region for the field with the lead foil. Therefore a new explanation for the unresolved discrepancy remains to be found.

Artifacts↗