Thermodynamic studies of the solvent effects in chromatography on molecularly imprinted polymers. 3. Nature of the organic mobile phase.

Experimental isotherm data of the Fmoc-tryptophan (Fmoc-Trp) enantiomers were measured by frontal analysis on a Fmoc-L-Trp imprinted polymer, using different organic mobile phases, in a wide concentration range. The nonlinear regression of the data and the independent calculation of the affinity energy distributions of the two enantiomers allowed the selection of the isotherm model and the determination of the isotherm parameters. The organic solvents studied were acetonitrile (MeCN), methylene chloride, chloroform, and tetrahydrofuran (THF), all in the presence of the same concentration of acetic acid, used as an organic modifier. It was found that the highest overall affinity and enantiomeric selectivity were obtained in MeCN, which is also the solvent used in the polymerization. In the other solvents, the overall affinity decreases with increasing hydrogen-bonding ability of the solvents but not the enantiomer selectivity. In MeCN, three types of adsorption sites coexist for the two enantiomers on the MIP. The highest energy sites for Fmoc-L-Trp in MeCN are inactive in CH(2)Cl(2), CHCl(3), and THF, and only two types of sites were identified in these solvents. Increasing the acetic acid concentration from 0.2 to 0.9 M causes a large decrease in the association constant of the highest energy sites in CH(2)Cl(2), CHCl(3), and THF but not in MeCN. The overall affinity of Fmoc-L-trp in CH(2)Cl(2), CHCl(3), and THF is dominated by adsorption on the lowest energy sites, the most abundant ones. In contrast, in MeCN, the overall affinity of Fmoc-L-Trp is dominated by adsorption on the highest energy sites, the least abundant sites. In CH(2)Cl(2), CHCl(3), and THF, the number of each type of sites increases with decreasing hydrogen-bonding ability of the solvents while the association constant of the corresponding sites does not change significantly.

Journal Article↗

Influence of the pressure on the properties of chromatographic columns. I. Measurement of the compressibility of methanol-water mixtures on a mesoporous silica adsorbent.

The compressibilities of aqueous solutions of methanol or acetonitrile containing 0, 20, 40, 60, 80 and 100% (v/v) organic solvent were measured with a dynamic chromatographic method. The elution volumes of thiourea samples (2 microL) in these solutions were measured at different average column pressures, adjusted by placing suitable capillary restrictors on-line, after the detector. The reproducibility of the measurements was better than 0.2%. In the range of average pressures studied (10-350 bar), the maximum change in elution volume of thiourea is 1.3% (in pure water) and 4.0% (in pure methanol). This difference is due to the different compressibilities of these pure solvents. For mixtures, the plots of the elution volume of thiourea versus the pressure are convex downward, which is inconsistent with the opposite curvature predicted by the classical Tait model of liquid compressibility. This difference is explained by the variation of the amount of thiourea adsorbed with the pressure. The deconvolution of the two effects, adsorption of thiourea and solvent compressibility, allows a fair and consistent determination of the compressibilities of the methanol-water mixtures. A column packed with non-porous silica particles was also used to determine the compressibility of methanol-water and acetonitrile-water mixtures. A negative deviation by respect to ideal behavior was observed.

Chromatography, Liquid↗

Influence of pressure on the properties of chromatographic columns. II. The column hold-up volume.

The effect of the local pressure and of the average column pressure on the hold-up column volume was investigated between 1 and 400 bar, from a theoretical and an experimental point of view. Calculations based upon the elasticity of the solids involved (column wall and packing material) and the compressibility of the liquid phase show that the increase of the column hold-up volume with increasing pressure that is observed is correlated with (in order of decreasing importance): (1) the compressibility of the mobile phase (+1 to 5%); (2) in RPLC, the compressibility of the C18-bonded layer on the surface of the silica (+0.5 to 1%); and (3) the expansion of the column tube (<0.001%). These predictions agree well with the results of experimental measurements that were performed on columns packed with the pure Resolve silica (0% carbon), the derivatized Resolve-C18 (10% carbon) and the Symmetry-C18 (20% carbon) adsorbents, using water, methanol, or n-pentane as the mobile phase. These solvents have different compressibilities. However, 1% of the relative increase of the column hold-up volume that was observed when the pressure was raised is not accounted for by the compressibilities of either the solvent or the C18-bonded phase. It is due to the influence of the pressure on the retention behavior of thiourea, the compound used as tracer to measure the hold-up volume.

Chromatography, Liquid↗

Effect of the flow rate on the measurement of adsorption data by dynamic frontal analysis.

The adsorption data of propyl benzoate were acquired by frontal analysis (FA) on a Symmetry-C18 column, using a mixture of methanol (65%, v/v) and water as the mobile phase, at three different flow rates, 0.5, 1.0 and 2.0 mL/min. The exact flow rates Fv were measured by collecting the mobile phase in volumetric glasses (deltaFv / Fv < or = 0.2%). The extra-column volumes and the column hold-up volume were accurately measured at each flow rate by tracer injections. The detailed effect of the flow rate on the value of the amount adsorbed was investigated. The best isotherm model accounting for the adsorption data was the same BET isotherm model at all three flow rates. Only slight differences (always less than 5%) were found between the three different sets of isotherm parameters (saturation capacity, q(s), equilibrium constant on the adsorbent, b(s) and equilibrium constant on successive layers of propyl benzoate, bL). The reproducibility of the same isotherm parameters measured by the inverse method (IM) is less satisfactory, leading to R.S.D.s of up to 10%. A flow rate increase is systematically accompanied by a slight increase of the amount adsorbed. This phenomenon is consistent with the influence of the pressure on the equilibrium constant of adsorption due to the difference between the partial molar volumes of the solute and the adsorbate. The larger average pressure along the column that is required to achieve a larger flow rate causes a larger amount of solute to be adsorbed on the column at equilibrium. This result comforts the high sensitivity and versatility of the FA method for isotherm determination under any kind of situation.

Adsorption↗

Thermodynamic studies on the solvent effects in chromatography on molecularly imprinted polymers. 1. Nature of the organic modifier.

Molecularly imprinted polymers (MIPs) are used as highly enantioselective stationary phases in liquid chromatography. To optimize the binding performance of MIPs, different types of polar modifiers are frequently used. Previous studies have shown that the hydrogen-bonding donor parameter (HBD) of the modifier has a large influence on the binding performance of MIPs in chiral separations. This possibility is addressed in a detailed thermodynamic study of a Fmoc-L-tryptophan (Fmoc-L-Trp) imprinted polymer, eluted with four different polar modifiers, i.e., THF, propan-2-ol, methanol, and acetic acid, which have different HBDs (0.00, 0.33, 0.43, and 0.61, respectively). Adsorption isotherm data for each enantiomer in each of these organic modifiers were acquired by frontal analysis over a 20 000 dynamic concentration range. Nonlinear regression of the isotherm data, along with independent calculation of the affinity energy distributions, identified four different types of binding sites coexisting for the enantiomers on the MIP. The exception was acetic acid, which has the highest HBD. In this case, three types of binding sites only coexist on the MIP. The isotherm parameters obtained from these data show the following: (1) The association energies of the two enantiomers with a given type of sites have a similar magnitude; however, the density of the sites is higher for the template than for its antipode. (2) The nature of the organic modifier has a larger influence on the density of high-energy sites than on the association constant of these sites. (3) The molecular size of the organic modifier has a larger influence on the site density (especially for Fmoc-D-Trp) than does HBD. (4) Using an organic modifier with a higher HBD reduces the enantioselectivity on each site. (5) High-energy sites are more enantioselective than low-energy ones. (6) Using an organic modifier with a high HBD causes a larger reduction in the density of high-energy sites approached by the template molecules.

Acetic Acid↗

Thermodynamic studies on solvent effects in molecularly imprinted polymers. 2. Concentration of the organic modifier.

The effects of the organic modifier concentration on the isotherm parameters of the two enantiomers of Fmoc-tryptophan (Fmoc-L,D-Trp) on an Fmoc-L-Trp-imprinted polymer were investigated over a wide concentration range (0.005-100 mM), using frontal analysis. The modifier was acetic acid; concentrations of 0.2, 0.9, 1.7, and 3.7 M in an acetonitrile-based mobile phase were studied. At each concentration, adsorption isotherm data were acquired for each enantiomer. From these data, the isotherm parameters of each compound were derived from nonlinear isotherm fitting and the affinity energy distributions were calculated independently. We found that three types of sites coexist for Fmoc-L-Trp but only two types of sites for Fmoc-D-Trp, except at the lowest acetic acid concentration (0.2 M), at which three types of sites coexist. Increasing the acetic acid concentration decreases the selectivity and the overall affinity of both enantiomers. The overall affinity of Fmoc-L-Trp is dominated by the contribution of the low-density highest energy sites while that of Fmoc-D-Trp is dominated by the most abundant, low-energy sites. For the low-energy sites, increasing the acetic acid concentration affects the association constant of the enantiomers more than the number of corresponding sites. In contrast, for the highest energy sites (sites that exist only for Fmoc-L-Trp), increasing the concentration of acetic acid affects significantly the number of sites but hardly changes the association constant.

Acetic Acid↗

Effect of the surface heterogeneity of the stationary phase on the range of concentrations for linear chromatography.

The range of sample sizes within which linear chromatographic behavior is achieved in a column depends on the surface heterogeneity of the RPLC adsorbents. Two widely different commercial adsorbents were tested, the end-capped XTerra-C18 and the non-end-capped Resolve-C18. Adsorption isotherm data of caffeine were acquired by frontal analysis. These data were modeled and used to calculate the adsorption energy distribution (AED). This double analysis informs on the degree of surface heterogeneity. The best adsorption isotherm models are the bi-Langmuir and the tetra-Langmuir isotherms for XTerra and Resolve, respectively. Their respective AEDs are bimodal and quadrimodal distributions. This interpretation of the results and the actual presence of a low density of high-energy adsorption sites on Resolve-C18 were validated by measuring the dependence of the peak retention times on the size of caffeine samples (20-microL volume, concentrations 10, 1, 0.1, 1 x 10(-2), 1 x 10(-3), 1 x 10(-4), and 1 x 10(-5) g/L). The experimental chromatograms agree closely with the band profiles calculated from the best isotherms. On Resolve-C18, the retention time decreases by 40% when the sample concentration is increased from 1 x 10(-5) to 10 g/L. The decrease is only 10% for Xterra-C18 under the same conditions. The upper limit for linear behavior is 1 x 10(-4) g/L for the former adsorbent and 0.01 g/L for the latter. The presence of a few high-energy adsorption sites on Resolve-C18, with an adsorption energy 20 kJ/mol larger than that of the low-energy sites while the same difference on Xterra is only 5 kJ/mol, explains this difference. The existence of adsorption sites with a very high energy for certain compounds affects the reproducibility of their retention times and a rapid loss of efficiency in a sample size range within which linear behavior is incorrectly anticipated.

Adsorption↗

Comparison of the thermodynamic properties of particulate and monolithic columns of molecularly imprinted copolymers.

A variety of polymerization techniques can be used to prepare molecularly imprinted copolymers (MIPs) for the purpose of the separation of enantiomers by HPLC. Unfortunately, the lack of thermodynamic and kinetic data characterizing the imprinted polymers prepared by these different techniques prevents the rational choice of the one most suited for a specific application. We investigated and compared the thermodynamic properties of copolymers imprinted for Fmoc-L-tryptophan and prepared by two different methods. The first was an in situ polymerization method that gives monolithic columns (monolithic MIPs), the second, a traditional method giving bulk MIPs. Examination of the thermodynamic properties on these two different MIPs showed that three types of binding sites coexist on their surface. The highest energy sites adsorb only the imprinted molecule or template. Most of the intermediate energy sites adsorb both the template and its antipode, although part of them may adsorb only the template. Finally, the lowest energy sites provide nonselective interactions of both the template and its antipode. On the nonimprinted copolymer, there are only two types of sites. The high-energy sites have a slightly lower energy that the intermediate sites of the MIPs, and the low-energy sites have properties close to those of the lowest energy sites on the MIPs. The monolithic MIPs have fewer nonselective sites than the bulk MIPs. However, the polar porogen that is needed to prepare the monolithic MIPs negatively affects the enantiomeric separation.

Journal Article↗

Elution of propranolol as an ion-pair complex by buffer solutions on C18-silica.

Propranolol (pK(a) = 9.4) was eluted on C(18)-bonded Kromasil, equilibrated with buffer solutions of methanol and water (40/60, v/v) containing a constant concentration of a counteranion (12 mM). Nine different counteranions were studied: Cl(-), I(-), NO(3)(-), SO(4)(2-), CH(3)COO(-), HOOCC(2)H(4)COO(-), (-)OOCC(2)H(4)COO(-), HOOCCOHCOOHCOO(-), HOOCCOHCOO(-)COO(-), and (-)OOCCOHCOO(-)COO(-). The co-cation was K(+) or Na(+). Vacancy perturbations were measured on three concentration plateaus of propranolol hydrochloride, at 1.2, 12, and 24 mM, by injecting 100 microL of a pure mixture of methanol and water (40/60, v/v). Indirect detection of the solvent, the counteranion, the co-cation, and the chloride ion was carried out at 325 nm, a wavelength at which only propranolol responds. In a 1.2 mM propranolol hydrochloride solution, there is a 10-fold excess of counteranions and only a positive perturbation peak, due to the excluded co-cation and eluting before the column hold-up time, and a large vacancy peak, associated with propranolol, were recorded. Association between propranolol and the counteranion in excess determines the retention time of this second perturbation. The hydrophobicity of the complexes increases in the order Cl(-) < CH(3)COO(-) approximately HOOCC(2)H(4)COO(-) < NO(3)(-) < I(-) < HOOCCOHCOOHCOO(-) < (-)OOCC(2)H(4)COO(-) < SO(4)(2-) approximately HOOCCOHCOO(-)COO(-) < (-)OOCCOHCOO(-)COO(-). Propranolol retention is larger in the presence of the trivalent citrate anion than in that of the bivalent citrate, succinate, or sulfate anions. It is larger with these bivalent anions than with any monovalent anion. Equal concentration of propranolol hydrochloride and buffer in the mobile phase reveals five system peaks associated with the five components (solvent, counteranion, co-cation, chloride, propranolol molecules). In contrast with monovalent anions, bivalent anions (sulfate, succinate, citrate) or trivalent anions (citrate) cause a reversal of the elution order of the perturbation peaks of chloride anions and buffer molecules. This confirms a competition between chloride and buffer anions to form ion pairs with propranolol. The retention of the perturbation signal of the buffer increases with increasing anion charge because multivalent anions can bind to several molecules of propranolol. The perturbation measurements demonstrate the influence of the valence and hydrophobicity of the buffer on the retention of ionizable compounds. The inverse method allowed the derivation of the isotherm parameters from the overloaded band profiles of propranolol. These values confirm that adsorbate-adsorbate interactions increase with increasing valence of the anions.

Journal Article↗

Adsorption of the enantiomers of 2,2,2-trifluoro-1-(9-anthryl)-ethanol on silica-bonded chiral quinidine-carbamate.

The adsorption isotherms of the enantiomers of 2,2,2-trifluoro-1-(9-anthryl)-ethanol from a toluene-acetonitrile solution onto a Chiris Chiral AX:QD1 column were measured using the pulse method. The isotherm data were modeled with a bi-Langmuir isotherm model, indicating the presence of two different types of adsorption sites on this stationary phase, nonselective and enantioselective sites. The latter are homogeneous but interact with both enantiomers, albeit with different energies. The thermodynamic characteristics of these two types of sites were characterized by their adsorption constants and saturation capacities and by the influence of the temperature on these different parameters.

Adsorption↗

Effect of the temperature on the isotherm parameters of phenol in reversed-phase liquid chromatography.

Adsorption isotherm data of phenol from an aqueous solution of methanol onto a C18-bonded silica (Symmetry-C18) were acquired by frontal analysis (FA) at six different temperatures, in a wide concentration range. The non-linear fitting of these data provided the bi-Langmuir model as best isotherm model, a conclusion further supported by the results of the calculation of the affinity energy distribution (AED). The isotherm parameters were obtained using several methods, the fitting of FA isotherm data, the calculation of the AED, and the inverse method, that uses overloaded elution band profiles. The different values obtained are in close agreement. They allow a quantitative investigation of the separate properties of the low- and the high-energy sites on the adsorbent surface. Increasing the temperature decreases the saturation capacity of the low-energy adsorption sites and the adsorption constant of the high-energy sites. In contrast, increasing the temperature does not cause any significant changes in either the saturation capacity of the high-energy sites or the adsorption constant of the low-energy sites.

Adsorption↗

Comparison between the adsorption behaviors of an organic cation and an organic anion on several reversed-phase liquid chromatography adsorbents.

Adsorption data of an organic cation (propranololium chloride) and an organic anion (sodium 1-naphthalene sulfonate) were measured by frontal analysis on two RPLC adsorbents, Symmetry-C18 and XTerra-C18, with aqueous solutions of methanol as the mobile phases. The influence of supporting neutral salts on the adsorption behavior of these two ions are compared. The Henry constants are close (H approximately 5). The four sets of isotherm data are all well accounted for using the bi-Moreau model. However, the isotherms of the two ions behave differently at high concentrations. The initial behaviors of all the isotherms are antilangmuirian but remain so in a much wider concentration range for the cation than for the anion, due to its stronger adsorbate-adsorbate interactions on the low-energy adsorption sites. The retention times of both ions increase with increasing concentration of neutral salt in the mobile phase, suggesting the formation of ion-pair complexes, with Cl- for the cation and with Na+ for the anion. The adsorbate-adsorbate interactions vanish in the presence of salt and the bi-Moreau isotherm model tends toward a bi-Langmuir model. Differences in adsorption behavior are also observed between the cation and the anion when bivalent inorganic anions and cations, respectively, are dissolved in the mobile phase. High concentration band profiles of 1-naphthalene sulfonic acid are langmuirian, except in the presence of a trivalent cation, while those of propranolol are antilangmuirian under certain conditions even with uni- or divalent cations.

Adsorption↗

Effect of the ionic strength of the solution and the nature of its ions on the adsorption mechanism of ionic species in RPLC III. Equilibrium isotherms and overloaded band profiles on Kromasil-C18.

In two companion papers, we have described the influence of the concentration and the nature of completely dissociated salts dissolved in the mobile phase (methanol:water, 40:60, v/v) on the adsorption behavior of propranolol (R'-NH2+-R, Cl-) on XTerra-C18 and on Symmetry-C18. The same experiments were repeated on a Kromasil-C18 column to compare the adsorption behavior of this ionic compound on these three different RPLC systems. The adsorption data of propranolol hydrochloride were first measured by frontal analysis (FA) using a mobile phase without salt. These data fit best to the Bi-Moreau model. Large concentration band profiles of propranolol were recorded with mobile phases containing increasing KCl concentrations (0, 0.002, 0.005, 0.01, 0.05, 0.1 and 0.2 M) and the best values of the isotherm coefficients were determined using the numerical solution of the inverse problem of chromatography. The general effect of a dissociated salt in the mobile phase was the same as the one observed earlier with XTerra-C18 and Symmetry-C18. However, obvious differences were observed for the shape of the band profiles recorded at low column loading (1.5 g/L, 250 microL injected). A long shoulder is visible at all salt concentrations and the band broadening is maximum at low salt concentrations. A slow mass transfer kinetics on the high-energy sites of the bi-Moreau model might explain this original shape. Five other salts (NaCl, CsCl, KNO3, CaCl2 and Na2SO4) were also used at the same ionic strength (J = 0.2 M). As many different band profiles were observed, suggesting that specific solute-salt interactions take place in the adsorbed phase.

Adsorption↗

Retention of ionizable compounds in reversed-phase liquid chromatography. Effect of the ionic strength of the mobile phase and the nature of the salts used on the overloading behavior.

The retention mechanism of the protonated cation in propranolol chloride on C18-Xterra was investigated using mobile phases of various compositions. Accurate adsorption data were measured by frontal analysis, with a mixture of methanol and water (25% methanol), with no salt, as the mobile phase. The experimental isotherm has at least two inflection points, at concentrations of about 0.2 and 6.0 g/L, respectively. This precludes the modeling of these data with a simple convex-upward isotherm (e.g., Langmuir). The adsorption energy distribution or relationship between the number of sites on the adsorbent surface and the energy of adsorption on these sites was calculated by assuming Moreau isotherm behavior (S-shaped isotherm). This model has never been applied to describe the surface heterogeneity of any RPLC adsorbent. The calculation converged toward a bimodal energy distribution. Accordingly, the bi-Moreau model is the simplest theoretical model accounting for the adsorption data of propranolol from a mobile phase without salt. The complex-overloaded band profiles of propranolol measured in the presence of increasing concentrations of a supporting salt (KCl) in the mobile phase demonstrate that the same isotherm model applies also under these conditions, as was merely assumed in a previous work. The elution band profiles of propranolol calculated with the bi-Moreau isotherm model for solutions of salts of different natures (CaCl2, CsCl, Na2SO4) in the same mobile phase agree very well with the experimental band profiles.

Adsorption↗

Isothermal microcalorimetric study of the pH dependence of the interactions between a cellulase and a beta-blocker.

The influence of the pH on the complexation equilibria between (S)- or (R)-alprenolol and the cellulase Cel7A was investigated by isothermal titration calorimetry. The results obtained agree with those of previous, similar studies of the same equilibria in which the protein was immobilized on silica particles, packed in a chromatographic column. The association constant and the complexation enthalpy and entropy of the (S)-enantiomer increase with increasing pH. For (R)-alprenolol, the binding is endothermic at all pH values. Thus, for both enantiomers in the pH range 5.5-6.8, the binding is an entropically driven process.

Adrenergic beta-Antagonists↗

Accuracy and precision of adsorption isotherm parameters measured by dynamic HPLC methods.

The fluctuations of the column temperature, the composition and the flow rate of the mobile phase affect the accuracy and precision of the adsorption isotherm parameters measured by dynamic HPLC methods. Experimental data were acquired by frontal analysis (FA) for phenol in equilibrium between C18-bonded Symmetry and a methanol:water mixture (20:80, v/v), at 303 K and a flow rate of 1 mL/min. The fluctuations of the experimental parameters were 0.1 K for the temperature, 0.1% for the mobile phase composition and 0.001 mL/min for the flow rate. The best isotherm model was shown to be the tri-Langmuir isotherm. Random errors were calculated and shown to agree with experimental results. Overloaded band profiles of phenol were acquired at low (sample size, 100 microL, concentration 3 g/L) and high (same sample size, concentration 60 g/L) loadings, at seven temperatures (298, 300, 302, 303, 304, 306, and 308 K), for seven mobile phase compositions (methanol 16, 18, 19, 20, 21, 22, and 24%), and with seven mobile phase flow rates (0.95, 0.97, 0.99, 1.00, 1.01, 1.03, and 1.05 mL/min), always keeping two experimental parameters at the values selected for the FA runs. Assuming that the isotherm model stays the same, the inverse method (IM) was used to derive the isotherm parameters in each case. Temperature affects the equilibrium constants according to Van't Hoff law. A temperature change of 1 K around 303 K causes a relative variation of 1.5% of the high-energy adsorption constant b3 and of 0.6% of the saturation capacity q3. The isotherm parameters are very sensitive to the mobile phase composition, especially the highest energy mode. Both adsorption constants b2 and b3 follow the linear strength solvent model (LSSM). A methanol volume fraction change of 1% causes a relative decrease of 3.2 and 5.0% of b2 and b3, respectively and a 2% decrease of the saturation capacity q3. Finally, flow rate changes affect only the saturation capacities. A flow rate change of 1 % causes a 2% change in the saturation capacity parameters.

Adsorption↗