PubMed Health⌕ Search

Biomedical subjects

Gerald E Rodts

Publications and source records attributed to Gerald E Rodts.

At least 19 recordsLinked to original sources

Combined ventral and dorsal surgery for myelopathy and myeloradiculopathy.

The past decade has witnessed significant advances in the surgical treatment of cervical myelopathy and myeloradiculopathy. In this article, we discuss in detail the indications for combined ventral and dorsal surgery for the treatment of cervical myelopathy and myeloradiculopathy. In addition, the advances in surgical technique and instrumentation in cervical spine surgery are explored. Finally, complication avoidance and management strategies are discussed. Combined ventral and dorsal decompression, reconstruction, and instrumentation procedures are viable options in the treatment of a select group of patients with complex cervical myelopathy or myeloradiculopathy.

Decompression, Surgical↗

Recurrent subdural hematoma caused by cerebrospinal fluid leakage. Case report.

The authors report a case of a recurrent subdural hematoma (SDH) that was caused by a persistent cerebrospinal fluid (CSF) leak from an L1-2 fistula. A 34-year-old man experienced severe headaches due to SDH, and he underwent aspiration of subdural fluid four times due to recurrent collections. Further evaluation with computerized tomography (CT) myelography demonstrated extradural extravasation of contrast through an L1-2 fistula. The patient underwent an L1-2 laminectomy; a small dural defect with CSF leakage at the left nerve root sleeve was found and was repaired. Following the repair, the patient had no further recurrence of SDH. Recurrent SDH, caused by spontaneous CSF leakage through a lumbar CSF fistula, is extremely rare. In cases of recurrent SDH, radiographic workup with spinal CT myelography should be considered.

Adult↗

Infected vertebroplasty requiring 360 degrees spinal reconstruction: long-term follow-up review. Report of two cases.

Transpedicular vertebroplasty has been established as a safe and effective treatment of thoracic and lumbar compression fractures. Complications are rare, and infectious complications requiring surgical management have only been reported once in the literature. The authors present two cases of infectious complications requiring surgical management. They emphasize that systemic infection is a contraindication to the performance of vertebroplasty. The serious nature of these infections, their surgical management, and strategies for avoiding them are discussed.

Enterobacteriaceae Infections↗

Occipitocervical fixation: long-term results.

STUDY DESIGN: The study is a retrospective review of 58 patients who underwent occipitocervical fusion between 1997 and 2001. OBJECTIVES: Our objective is to study the clinical results after occipitocervical fixation with long-term follow-up and assess factors contributing to clinical success. METHODS: Data from patient charts, operative notes, physician office notes, and imaging studies were incorporated in the study. Myelopathy was assessed using a Nurick scale for preoperative and postoperative evaluation. Fusion was assessed using cervical plane films with flexion and extension views. RESULTS: Mean follow-up was 36 months, with all patients having a greater than 1-year follow-up. The most common pathology was congenital cranial settling (41%) followed by trauma (22%) and rheumatoid arthritis (17%). Myelopathy was the most common presentation (62%) followed by pain (28%). A successful fusion occurred in 48 out of 51 patients (94%). Symptoms improved in 86% of patients, whereas 35% improved 1 Nurick grade. Complications occurred in 30% of patients. The cervical wound infection rate was 5%. The rate of adjacent level degeneration was 7%. The mortality rate was 1.7%. CONCLUSIONS: Occipitocervical instrumentation allows for very high fusion rates without the need for halo vest immobilization. All patients with successful fixation have pain resolution. Myelopathy improves in most patients, whereas one-third of patients demonstrate dramatic improvement.

Adolescent↗

The mini-open transforaminal lumbar interbody fusion.

The mini-open approach for transforaminal lumbar interbody fusion is described in detail. Operating room setup and surgical positioning are demonstrated. Our methods of retractor placement and techniques for optimal surgical exposure are discussed. The surgical technique used for decompression and fusion is presented in detail. The surgical pearls and pitfalls of the mini-open TLIF are described and illustrated.

Humans↗

Infected vertebroplasty. Report of two cases and review of the literature.

Transpedicular vertebroplasty has been established as a safe and effective treatment for thoracic and lumbar compression fractures. Complications are rare and infectious complications requiring surgical management have only been reported once in the literature. In this paper the authors present two patients in whom osteomyelitis developed after vertebroplasty in which corpectomy was required. The serious nature of these infections, their surgical management, and complication avoidance are discussed.

Aged↗

Posterior cervical laminoplasty using a new plating system: technical note.

BACKGROUND: Laminoplasty is well described in the Japanese literature as a surgical option for treating ossification of the posterior longitudinal ligament (OPLL). The open door technique has gained increasing popularity in the United States and Europe to treat not only OPLL but also cervical stenotic myelopathy. An obstacle to its widespread use is the lack of a suitable fixation plate to adequately secure the fractured lamina to the lateral mass. Our objective was to demonstrate the advantages of a novel miniplate (Ti-Mesh LP system; Medtronic Sofamor Danek, Memphis, TN, USA) that is ideally suited for fixing the lamina to the lateral mass. METHODS: We used the Ti-Mesh LP miniplate system to perform laminoplasties on five patients, all male, with a mean preoperative Nurick score of 2.8. Four patients had congenital cervical stenosis with myelopathy and one had OPLL. Open door laminoplasties were performed on all patients. The plates were implanted with a claw positioned on the trapdoor lamina and a flat plate on the lateral mass. RESULTS: The system was implanted successfully in all patients. The mean number of levels fixated was 4.4. There were no intraoperative or postoperative complications after >5 months follow-up. CONCLUSIONS: The new Ti-Mesh LP cranial miniplate and screw system facilitates posterior cervical laminoplasty procedures by eliminating the need to contour cranial miniplates for use in the cervical spine. Its unique claw construct and angled design are ideal for holding a trapdoor laminoplasty in the open position. We have used this system successfully and without complications to perform decompressive posterior cervical laminoplasties in five patients.

Aged↗

Contribution of recombinant human bone morphogenetic protein-2 to the rapid creation of interbody fusion when used in transforaminal lumbar interbody fusion: a preliminary report. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004.

OBJECT: The authors compared fusion rates in transforaminal lumbar interbody fusion (TLIFs) when using either autograft or bone morphogenetic protein (BMP) placed in the interbody space. METHODS: Between September 2002 and December 2003, the authors performed 44 TLIF operations. Follow-up data were available for 40 patients. Of the 40 procedures, 19 involved cages filled with iliac crest autograft (Group 1) and 21 involved cages filled with a medium kit of recombinant human (rh) BMP-2 (Group 2). In all Group 2 patients, one BMP sponge was placed anterior to the cage and another was placed within the cage. In 12 of the Group 2 patients, iliac crest autograft was placed posterior to the BMP-filled cage (Group 2A). In the remaining nine Group 2 patients, only local autograft was placed posterior to the BMP-filled cage (Group 2B). Assessment of fusion was performed using dynamic radiography at 3-month intervals. Outcomes were assessed using the Prolo Scale, and iliac crest donor site pain was measured using a Visual Analog Scale (VAS). The mean follow-up period was 9 months (range 3-18 months). In Group 1 patients, one pseudarthrosis was detected. In Group 2 patients, dynamic radiography demonstrated solid fusion in all patients except one in Group 2B. Fifty-eight percent of patients in whom iliac crest autograft was used complained of donor site pain 6 months after surgery (5 of 10 points on the VAS). Symptomatic foraminal bone formation was not observed in any Group 2 patient. CONCLUSIONS: The use of rhBMP-2 is safe in TLIFs when the sponges are placed away from the dura mater, and BMP promotes a more rapid fusion than iliac crest autograft alone. The use of rhBMP-2 in combination with local autograft is an excellent option for promoting solid fusion with TLIF, and it eliminates the possibility of iliac donor site pain.

Adult↗

Lumbar interbody fusion: state-of-the-art technical advances. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004.

During the past few decades, three techniques have been used to achieve circumferential lumbar interbody fusion (LIF). They include posterior LIF, anterior LIF with supplemental posterior fixation, and transforaminal LIF. In this article, the authors describe the indications and contraindications for the use of interbody fusion. The advantages and disadvantages of each will be discussed in detail. Additionally, strategies for minimally invasive access and options for interbody spacer materials will be discussed.

Humans↗

Postlaminectomy cervical deformity.

Postlaminectomy cervical kyphosis is an important consideration when performing surgery. Identifying factors predisposing to postoperative deformity is essential. The goal is to prevent postlaminectomy cervical kyphosis while exposing the patient to minimal additional morbidity. When postlaminectomy kyphosis does occur, surgical correction is often required and performed via an anterior, posterior, or combined approach. The authors discuss the indications for surgical approaches as well as clinical results.

Adult↗

Benign sacral tumors.

Primary tumors of the sacrum are rare. In adults, the most common sacral tumors are metastases. The most common primary sacral tumor is a chordoma. Chordomas along as well as tumors such as chondrosarcomas, osteosarcomas, myxopapillary ependymomas, myelomas, and Ewing sarcomas are considered malignant. In this article the authors focus on benign sacral tumors.

Adolescent↗

Cervical osteotomy for the correction of chin-on-chest deformity in ankylosing spondylitis. Technical note.

The correction of chin-on-chest deformity is challenging and requires combined anterior and posterior approaches to the cervical spine. The authors describe a cervical osteotomy technique for the correction of chin-on-chest deformity in patients with ankylosing spondylitis (AS). This procedure can be accomplished using a posterior screw rod construct combined with an anterior hybrid plate system. In patients with AS, a "front-back-front" approach may be necessary because of the deformity's rigidity. The authors describe the complicated intubation and anesthetic requirements for this approach. They performed an anterior discectomy, cervical osteotomy, and unilateral pediculectomy but did not place anterior instrumentation. Via a posterior approach, laminectomies, facetectomies, and the contralateral pediculectomy were then undertaken. A posterior cervical screw/rod system was placed and loosely connected to titanium rods. Intraoperatively the deformity was corrected by placing the neck in extension combined with compression of the posterior screws on the rods. The posterior construct is then tightened. Finally, an anterior cervical approach is performed to place a structural interbody graft and a hybrid anterior cervical plate construct. The authors have successfully used this approach to correct a chin-on-chest deformity in a patient with ankylosing spondylitis. At 1-year follow-up examination, excellent resolution of the deformity and solid fusion had been achieved. They prefer to perform this procedure by using state-of-the-art anterior and posterior instrumentation systems.

Bone Plates↗

Early results using the Atlantis anterior cervical plate system.

OBJECT: The authors present a retrospective review of 77 patients in whom they performed anterior cervical discectomy and fusion (ACDF) in the treatment of radiculopathy and/or myelopathy. In all cases anterior interbody fusion was performed using the Atlantis locking plate system to treat the degenerative disease. METHODS: There were 41 men and 36 women (mean age 53.8 years), and 24 active cigarette smokers (31%) in the group. All patients presented with signs and symptoms of cervical radiculopathy and/or myelopathy, and magnetic resonance imaging or computerized tomography myelography demonstrated evidence of radicular and/or spinal cord compression at one or more cervical levels. Thirty-one patients underwent single-level ACDF, 20 patients underwent multilevel ACDF without posterior instrumentation, in eight patients one- to four-level corpectomies were supplemented with posterior fixation, 12 patients underwent single-level corpectomy, and six patients underwent multilevel corpectomy with no posterior instrumentation. The mean follow-up period was 15.33 months; overall good-to-excellent outcome was seen in 75% of patients; osseous fusion was demonstrated in 93.5%. In all patients except three, fibular allograft was used as graft material. The degree of overall cervical lordosis was measured at the last follow up and was compared with normal values obtained in age-matched individuals. In addition, the degree of cervical lordosis at fusion levels was compared with overall cervical lordosis. In patients in all five of the aforementioned categories significantly less lordosis was demonstrated than in age-matched controls. In patients who underwent single-level ACDF, single-level corpectomy, and multilevel ACDF significantly less lordosis was observed at the fusion segment than that in the overall cervical spine. Complications included one episode of chronic anterior wound drainage treated with intravenous antibiotic medication and one postoperative posterior wound infection, which required reoperation and intravenous antibiotic medication. Two cases (2.6%) of anterior screw backout and/or breakage were identified. One patient died of unrelated causes within 3 months of operation. CONCLUSIONS: These initial results indicate that use of the Atlantis plate system for anterior cervical arthrodesis produces fusion rates and clinical outcomes that are comparable with those obtained using other locking plating systems. It has the unique advantage, however, of providing the surgeon with the choice of fixed, variable, or hybrid screw constructs as a way of tailoring screw angles to individual anatomical/biomechanical needs.

Adult↗

The Cervical Spine Study Group anterior cervical plate nomenclature.

The authors review historical and biomechanical aspects of anterior cervical plate (ACP) systems. They propose a novel classification system for ACPs based on the biomechanical and graft-loading properties of these systems. A retrospective review of the literature comprising both clinical and laboratory investigations regarding the ACP system was undertaken. Comparison of each system is considered in the context of the biomechanical attributes and graft-loading properties of each type of plate. Salient characteristics reviewed include restriction of screw backout, screw-angle variability, and mobility at the screw-plate interface. A new classification system for ACPs is proposed that primarily considers the ability of the construct to restrict screw backout, as well as the properties of the plate-screw interface--that is, the capacity for rotational or translational movement. A new classification system is presented that provides unified, biomechanically descriptive nomenclature. Using this nomenclature, the ACP devices currently available and those developed in the future can be uniformly categorized.

Biomechanical Phenomena↗

Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series.

OBJECT: A variety of techniques may be used to achieve fixation of the upper cervical spine. Transarticular atlantoaxial screws, posterior interspinous cable and graft constructs, and interlaminar clamps have been used effectively to achieve atlantoaxial fixation. Various anatomical factors, however, may preclude the successful application of these techniques. These factors include aberrant vertebral artery anatomy, irreducible atlantoaxial subluxation, exaggerated cervicothoracic kyphosis, and the absence of the osseous substrate for fixation. In these cases, an alternative method of fixation must be performed. The authors present an alternative method to achieve fixation of the atlas in which lateral mass screws can be applied to atlantoaxial and occipitocervical fixation. METHODS: Between February 1998 and November 2001, eight patients who ranged in age from 16 to 74 years underwent posterior fixation for upper cervical instability. Diagnoses included C-2 metastastic disease in two patients, irreducible odontoid fractures in two patients, atlantoaxial subluxation in two patients, and transverse ligament synovial cyst in two patients. Various anatomical factors precluded transarticular atlantoaxial screw fixation in seven patients. One patient with a highly unstable spine due to a C-2 metastasis and pathological fracture underwent occipitocervical fusion. Atlantocervical fixation was achieved in seven patients by using varying constructs incorporating C-1 lateral mass screws. Occipitocervical fixation was achieved in one patient by incorporating C-1 lateral mass screws as an additional fixation point. A total of 14 C-1 lateral mass screws were placed in eight patients. There were no intraoperative complications. In all patients rigid fixation was achieved as demonstrated on postoperative radiographs. One patient died on postoperative Day 9 of aspiration pneumonia. At a mean follow-up time of 7.4 months, rigid fixation was maintained in all patients. CONCLUSIONS: Atlantal lateral mass screws can be used to provide a safe and efficacious means of achieving atlantoaxial fixation when anatomical constraints preclude the use of a more traditional procedure. Atlantal lateral mass screws may also be incorporated in occipitocervical constructs to provide additional fixation points which may prevent construct failure.

Adolescent↗

Posterior cervical fixation using a new polyaxial screw and rod system: technique and surgical results.

OBJECT: Standard lateral mass plate and screw systems are of limited use in patients with abnormal cervical anatomy and do not easily allow for extension to either the occipit or the thoracic spine. The objective of this study was to demonstrate the safety, surgical efficacy, and advantages of a new cervical polyaxial screw and rod system for posterior occipitocervicothoracic arthrodesis. METHODS: The authors reviewed a multicenter series of patients who underwent surgery in which they used a new posterior cervical polyaxial screw and rod system. The system was implanted in 32 (20 women and 12 men) adult patients (mean age 56.9 years, range 23-84 years). Twenty-three of the patients were treated for spondylostenosis; four for cervical fracture/dislocations; four for kyphosis; and one patient was treated for pseudarthrosis that developed after prior surgery. The system was successfully implanted in all patients despite the presence of anatomical lateral mass anomalies in the majority of cases. The mean number of levels fused was 3.9 (range one-eight levels). This dynamic system allowed for screw placement into the occiput, C-1 lateral masses, C-2 pars, C3-7 lateral masses, and low cervical as well as upper thoracic pedicles. Selective application of compressive or distractive forces was possible in adjacent segments. Surgery-related complications included one dural tear and one malpositioned screw. There were two cases of wound infection. CONCLUSIONS: Unlike standard lateral mass plate and screw systems, the new cervical polyaxial screw and rod system easily accommodates severe degenerative cervical spondylosis and curvatures. This instrumentation system allows for polyaxial screw placement with subsequent multiplanar rod contouring and offset attachment. The authors have used this system successfully, and without significant complications, to achieve posterior cervical arthrodesis.

Adult↗

Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft.

OBJECTIVE: Anterior plate fixation has gained widespread acceptance for the treatment of cervical spondylosis, theoretically enhancing the rate of arthrodesis. There are few studies comparing fusion rates after anterior cervical discectomy and fusion (ACDF) with and without a plate. The purpose of this study was to evaluate the efficacy of anterior cervical plating for fusion enhancement after one- and two-level ACDF with cortical allograft. METHODS: A retrospective review was performed with 251 patients who underwent one- or two-level ACDF with cortical allograft and plate stabilization between 1993 and 1999. An independent surgeon reviewer determined fusion status and complications. A successful fusion was defined by the absence of lucency around the graft, evidence of bridging bone between the endplate and the graft, and the absence of movement on dynamic imaging scans. Follow-up data, ranging from 9 months to 3.6 years, were available for 233 patients. A control group of 289 patients who underwent ACDF without plating was described in a previously published report by the senior author (RWH). Therefore, a total of 540 patients were evaluated for determination of the efficacy of anterior cervical plating with cortical allograft bone. Statistical significance was determined by chi(2) test. RESULTS: The fusion rates for one- and two-level ACDF with anterior fixation were 96 and 91%, respectively, compared with 90 and 72% for one- and two-level ACDF without anterior fixation. The observed increases in fusion rates for both one- and two-level procedures proved to be statistically significant (P < 0.05). There were no recorded infectious, neurological, or graft-related complications among the cohort treated with anterior cervical plating. Compared with the results for the cohort treated without anterior cervical plates, there was a statistically significant decrease in the graft-related complication rate with the application of plates (P < 0.001). Two patients who received plates were noted to have adjacent-segment degenerative changes that required surgical intervention. No hardware fractures were noted; however, one patient was noted to have a single displaced screw, without clinical consequences. CONCLUSION: The use of anterior cervical plating after one- and two-level ACDF with allograft cortical bone significantly enhanced arthrodesis. The improved fusion rate and negligible complication rate associated with anterior cervical plating are compelling factors justifying its use in the treatment of cervical spondylosis.

Adult↗