Gesture standardization increases the reproducibility of 3D kinematic measurements of the knee joint.

BACKGROUND: The literature on the 3D kinematics of the knee suggests that the gesture accomplished during kinematic assessment might play a significant role in the values measured. The purpose of this study is to demonstrate that a standardized gesture leads to an increased reproducibility in 3D kinematic measurements of the knee. METHODS: Seventeen healthy male subjects performed series of knee-bends in standardized and unconstrained conditions while their left knee's 3D kinematics were recorded using an optical motion-recording system. Standardized knee-bends were performed in a specially designed structure stabilizing the shoulders, pelvis and feet. Coefficient of multiple correlation were calculated for the ascent and the descent phases of the knee-bends for the tibial rotation and abduction/adduction components of the knee movement. FINDINGS: Comparisons between coefficient of multiple correlation of the different gesture conditions showed a statistically significant increase in reproducibility for the tibial rotation during the standardized knee-bends. INTERPRETATION: It appears that gesture standardization is an interesting option to consider for precise kinematic assessment of the living human knee.

Adult↗

A reproducible method for studying three-dimensional knee kinematics.

The methods used in movement analysis often rely on the definition of joint coordinate systems permitting three-dimensional (3D) kinematics. The first aim of this research project was to present a functional and postural method (FP method) to define a bone-embedded anatomical frame (BAF) on the femur and tibia, and, subsequently, a knee joint coordinate system. The repeatability of the proposed method was also assessed. Using FP method to define the BAFs, 4 kinematic parameters (flexion/extension, abduction/adduction, tibial internal/external rotation, and antero-posterior translation) were computed for 15 subjects walking on a treadmill. The repeatability for all four kinematic parameters was then assessed, using intra- and inter-observer settings. After pooling the results for all observers, the mean repeatability value ranged between 0.4 degrees and 0.8 degrees for rotation angles and between 0.8 and 2.2 mm for translation.

Adolescent↗