PubMed Health⌕ Search

Biomedical subjects

Gerard Rozing

Publications and source records attributed to Gerard Rozing.

5 recordsLinked to original sources

Multi-dimensional HPLC/MS of the nucleolar proteome using HPLC-chip/MS.

The proteome of the human nucleolus was investigated in a single analysis using off-line strong cation exchange chromatography and microfraction collection combined with HPLC-chip/MS. The analysis was conducted either as a 1-D workflow with HPLC-chip alone or as a 2-D workflow. Two hundred and six unique proteins were identified in the International Protein Index human database corresponding to 2024 unique tryptic peptides identified in the 2-D analysis. In contrast, only 34 proteins and 151 corresponding tryptic peptides were found by applying a 1-D separation strategy. This clearly indicated that the complexity of the samples required the combination of more than one orthogonal separation technique. Stringent database search criteria, including reversal of sequences and therefore better exclusion of false-positive identifications, were applied for reliable protein identification.

Cell Nucleolus↗

Instrumentation for advanced microseparations in pharmaceutical analysis and proteomics.

Small-volume chromatographic columns are only able to generate narrow peaks when flow rates, injection volume and instrument components, such as detector, connecting tubing and fittings, are matched to the peak dispersion from the column. Criteria for the proper design of chromatographic instrumentation are therefore derived from a general model on total dispersion. The performance of such a system is then experimentally evaluated from applications run on narrow-bore, small-volume columns. In order to achieve flow rates that match the dimensions of such columns, a new concept for electronic flow control (EFC) is introduced. A theoretical optimization of column efficiency and throughput is discussed and the results verified with practical examples on short, narrow-bore columns packed with small, porous and superficially porous particles. For complex sample mixtures, the concept of peak capacity is introduced and applied to orthogonal separation principles in multiple chromatographic dimensions through column switching techniques.

Chromatography, High Pressure Liquid↗

An experimental study of chromatographic dynamics in open and packed non-cylindrical conduits.

A systematic investigation of the influence of the perimeter shape of open and particle packed fused silica capillaries on chromatographic properties such as resistance to flow and dispersion of solutes propelled through these channels has been conducted. Verifications of these uncommon experiments with existing theoretical treatments are presented and the insights transferred to a novel polymer chip design with integrated facilities for complex separations. A comparison of the chromatographic performance of a real life proteomics sample on this chip with a capillary column of "similar" dimensions is presented.

Chromatography, High Pressure Liquid↗

Analysis of dimeric cyanine-nucleic acid dyes by capillary zone electrophoresis in N,N-dimethylacetamide as non-aqueous organic solvent.

A method based on capillary zone electrophoresis is presented for the determination of the purity of commercial dimeric cyanine dyes (TOTO, YOYO, BOBO, all -1 and -3 species, LOLO-1, POPO-1) that are common as fluorescent probes for nucleic acid staining. These dyes are tetracharged cations, and have a strong tendency to interact with negatively charged centres, where they are rapidly adsorbed, especially from aqueous solutions. Thus anionic sites at the capillary wall must be avoided, and aqueous buffers are not suitable. The method introduced here avoids both complications, using non-aqueous N,N-dimethylacetamide as solvent, and suppressing the dissociation of silanol groups at the capillary surface due to selection of acidic separation conditions (20 mmol/l perchloric acid as background electrolyte). The present method enables the determination of the purity of all 10 dyes in less than 15 min. The selectivity of the method allows separation of at least five main and differentiating a number of unresolved minor contaminants as demonstrated in detail for TOTO-3 as an example. Quantitation (with 100% normalisation of the peak areas) of nine lots of this dye results in a purity between 33 and 87%.

Acetamides↗

Microemulsion electrokinetic chromatography versus capillary electrochromatography-UV-mass spectrometry for the analysis of flunitrazepam and its major metabolites.

Benzodiazepines, namely flunitrazepam and its three major metabolites, were successfully separated by microemulsion electrokinetic chromatography. Separation was achieved using an untreated fused-silica capillary (48 cm (effective length 40 cm) x 50 num) at 25 kV; detection was performed by UV at 220 nm. The microemulsion system consisted of 70 mM octane, 800 mM 1-butanol, 80 mM sodium dodecyl sulfate (SDS) and 10 mM borate buffer, pH 9. Very high efficiencies (up to 400 000 plates) and resolution better than 3 were achieved. Since this technique is not compatible with mass spectrometry (MS) detection, a capillary electrochromatographic (CEC) method was developed to separate flunitrazepam and its metabolites. The effects of mobile phase composition and pH as well as voltage and temperature were systematically investigated. The optimized CEC method allowed the baseline separation of the investigated compounds. For the on-line coupling of CEC with electrospray ionization-mass spectrometry, the column was connected to a void fused-silica capillary using a Teflon connection. This configuration was found efficient and suitable for hyphenation of commercial CEC and MS instrumentation using commercially available CEC columns.

Anti-Anxiety Agents↗