PubMed Health⌕ Search

Biomedical subjects

Gerardo I Sanchez-Ortiz

Publications and source records attributed to Gerardo I Sanchez-Ortiz.

2 recordsLinked to original sources

Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithm.

In this paper an automatic atlas-based segmentation algorithm for 4D cardiac MR images is proposed. The algorithm is based on the 4D extension of the expectation maximisation (EM) algorithm. The EM algorithm uses a 4D probabilistic cardiac atlas to estimate the initial model parameters and to integrate a priori information into the classification process. The probabilistic cardiac atlas has been constructed from the manual segmentations of 3D cardiac image sequences of 14 healthy volunteers. It provides space and time-varying probability maps for the left and right ventricles, the myocardium, and background structures such as the liver, stomach, lungs and skin. In addition to using the probabilistic cardiac atlas as a priori information, the segmentation algorithm incorporates spatial and temporal contextual information by using 4D Markov Random Fields. After the classification, the largest connected component of each structure is extracted using a global connectivity filter which improves the results significantly, especially for the myocardium. Validation against manual segmentations and computation of the correlation between manual and automatic segmentation on 249 3D volumes were calculated. We used the 'leave one out' test where the image set to be segmented was not used in the construction of its corresponding atlas. Results show that the procedure can successfully segment the left ventricle (LV) (r = 0.96), myocardium (r = 0.92) and right ventricle (r = 0.92). In addition, 4D images from 10 patients with hypertrophic cardiomyopathy were also manually and automatically segmented yielding a good correlation in the volumes of the LV (r = 0.93) and myocardium (0.94) when the atlas constructed with volunteers is blurred.

Algorithms↗

Automated 3-D echocardiography analysis compared with manual delineations and SPECT MUGA.

A major barrier for using 3-D echocardiography for quantitative analysis of heart function in routine clinical practice is the absence of accurate and robust segmentation and tracking methods necessary to make the analysis automatic. In this paper, we present an automated three-dimensional (3-D) echocardiographic acquisition and image-processing methodology for assessment of left ventricular (LV) function. We combine global image information provided by a novel multiscale fuzzy-clustering segmentation algorithm, with local boundaries obtained with phase-based acoustic feature detection. We then use the segmentation results to fit and track the LV endocardial surface using a 3-D continuous transformation. To our knowledge, this is the first report of a completely automated method. The protocol is evaluated in a small clinical case study (nine patients). We compare ejection fractions (EFs) computed with the new approach to those obtained using the standard clinical technique, single-photon emission computed tomography multigated acquisition. Errors on six datasets were found to be within six percentage points. A further two, with poor image quality, improved upon EFs from manually delineated contours, and the last failed due to artifacts in the data. Volume-time curves were derived and the results compared to those from manual segmentation. Improvement over an earlier published version of the method is noted.

Algorithms↗