PubMed Health⌕ Search

Biomedical subjects

Gerd Bodner

Publications and source records attributed to Gerd Bodner.

42 records · Page 3Linked to original sources

Nontumorous vascular malformations in the liver: color Doppler ultrasonographic findings.

OBJECTIVE: To investigate color Doppler and spectral wave characteristics of nontumorous vascular malformations in the liver. METHODS: From September 1995 to January 2001, 32 cases of vascular malformations were identified by means of color Doppler ultrasonography and spectral wave analysis. Computed tomography, angiography, or both were performed in all cases. RESULTS: Five arterioportal and 14 portovenous malformations, 1 arteriovenous malformation, and 4 portoportal and 8 venovenous shunts were detected. Associations with Rendu-Osler-Weber syndrome in 6 cases and with cirrhotic liver in 12 cases were found Fourteen patients were liver disease free. In 3 cases, interventional procedures were necessary to reduce portal hypertension or cardiac dysfunction. The incidence of finding vascular malformations in 12,000 patients was 0.1%. CONCLUSIONS: Nontumorous vascular malformations are rare disorders in the liver. They may appear in patients with healthy livers and in patients with portal hypertension. Color Doppler ultrasonography and spectral wave analysis are capable of showing and differentiating different types of hepatic vascular malformations.

Adolescent↗

High-resolution sonography of lower extremity peripheral nerves: anatomic correlation and spectrum of disease.

OBJECTIVE: The value of sonography for the diagnosis of diseases of the peripheral nervous system is only little known. This image presentation is intended to raise the awareness of sonographers and clinicians of the potential of sonography by giving an anatomic-sonographic correlation of lower extremity peripheral nerves and an overview of commonly encountered diseases. METHODS: On 2 lower extremity cadaver specimens, peripheral nerves were imaged in typical locations such as the tarsal tunnel. During sonography the nerve was injected with blue dye, and thin-slice anatomic sections were obtained at the scan level with a chain saw. In addition, sonographic images of patients with typical diseases are shown. RESULTS: An excellent anatomic-sonographic correlation was obtained, which underlines the feasibility of sonography for imaging of lower extremity peripheral nerves. Reliable results may be obtained with sonography of typical disease processes of lower extremity peripheral nerves. CONCLUSIONS: Recent developments in sonographic technology such as the introduction of high-frequency linear array transducers, compound imaging, and extended field-of-view imaging strongly improve the applicability of transcutaneous sonography for the examination of peripheral nerve disease.

Cadaver↗

Persistent median artery in the carpal tunnel: color Doppler ultrasonographic findings.

OBJECTIVE: To describe the ultrasonographic and color Doppler ultrasonographic findings in 2 patients with carpal tunnel syndrome associated with a persistent median artery and to report the frequency of this anatomic variation in healthy volunteers. METHODS: Two patients with the clinical appearance of carpal tunnel syndrome and 100 wrists and distal forearms of 50 asymptomatic volunteers were examined with ultrasonography and color Doppler ultrasonography. The frequency and size of a persistent median artery and its relationship to median nerve anatomy in the carpal tunnel were evaluated. RESULTS: A large persistent median artery of 3 mm in diameter was found in the affected hands in both patients with carpal tunnel syndrome. Findings were confirmed at surgery. Among the asymptomatic volunteers, a persistent median artery could be found in 13 (26%, 10 [20%] unilateral and 3 [6%] bilateral), with a mean diameter of 1.1 mm (range, 0.5-1.7 mm). In 10 (63%) of 16 hands, the persistent median artery was associated with high division of the median nerve or a bifid nerve configuration in the carpal tunnel. CONCLUSIONS: A persistent median artery is a common condition in healthy individuals and in most cases is related to median nerve variations such as high division or a bifid nerve. Because a persistent median artery has a superficial course close to the transverse carpal ligament, preoperative diagnosis of this anatomic variation may be of clinical importance.

Adult↗

The vascular nature of hemorrhoids.

The arterial blood supply of the internal hemorrhoidal plexus is commonly believed to be associated with the pathogenesis of hemorrhoids. Ultrasound-supported proctoscopic techniques with Doppler-guided ligature of submucosal rectal arteries have been introduced for the therapy of hemorrhoids. The present investigation focuses on caliber and flow changes of the terminal branches of the superior rectal artery (SRA) supplying the corpus cavernosum recti (CCR) in patients with hemorrhoids. Forty-one outpatients (17 female, 24 male; mean age 48 years) with hemorrhoids of Goligher grades I-IV were compared with 17 healthy volunteers (nine female, eight male; mean age 29 years) by means of transperineal color Doppler ultrasound. The mean caliber of the arterial branches in the study group with hemorrhoids was 1.87 +/- 0.68 mm (range, 0.6 to 3.60 mm) and 0.92 +/- 0.15 mm (range, 0.6 to 1.2 mm) in the control group (P < 0.001). The arterial blood flow was significantly higher in patients with hemorrhoids than in the control group (mean 33.9 vs. 11.9 cm/second, P < 0.01). Our findings demonstrate that increased caliber and arterial blood flow of the terminal branches of the SRA are correlated with the appearance of hemorrhoids. We suggest that the hypervascularization of the anorectum contributes to the growth of hemorrhoids rather than being a consequence of hemorrhoids. Transperineal color Doppler ultrasound (CDUS) is an appropriate method to assess these findings in patients with hemorrhoids.

Adult↗

Ultrasound-guided periradicular injections in the middle to lower cervical spine: an imaging study of a new approach.

BACKGROUND AND OBJECTIVES: The objective of this study was to show the efficacy of ultrasound in facilitating the performance of a simulated cervical periradicular injection in cadavers. METHODS: A total of 40 ultrasound-guided examinations at 4 levels (C3 to C7) were performed on 4 embalmed cadavers. The cervical spinal nerves were located with ultrasound. First, the transverse process of each level was taken as a sonoanatomic landmark. The most lateral aspect of the transverse process of the seventh cervical vertebra was then established as the reference point. Ipsilateral distances (A, B, C, and D) between this point and each one of the transverse processes of the cervical spine up to the third vertebra were then computed. Subsequently, coronal computed tomography (CT) scans were taken to verify these distances. In a second part, a spinal needle was advanced under ultrasound guidance to the spinal nerves C5 to C8 on both sides of one cadaver. The exact placement of the needle tips was checked by CT. RESULTS: The transverse processes were identified in all cadavers. In 5 attempts, a depiction of the spinal nerves was not possible. Ultrasound and CT provided the same mean measurements of 1.1 cm, 2.1 cm, 3.1 cm, and 4.1 cm for distances A, B, C, and D, respectively. All 8 needle tips were placed within 5 mm dorsal to the spinal nerve and less than 5 mm away from the posterior tubercle of each level's transverse process, as also verified by CT. CONCLUSIONS: This preclinical study suggests that ultrasound is a useful guiding tool for periradicular injections in the cervical spine.

Cervical Vertebrae↗

Ultrasound-guided facet joint injections in the middle to lower cervical spine: a CT-controlled sonoanatomic study.

OBJECTIVES: The aim of this study was to investigate the efficacy of ultrasound as a guiding tool for simulated cervical facet joint injections in cadavers. METHODS: A total of 40 ultrasound examinations at 5 levels (C6-7 to C2-3) were performed on 4 embalmed cadavers. The zygapophyseal joints were located with ultrasound. First, the transverse processes of C6 and C7 were established and the facet joint of C6-7 was demonstrated. The midpoint of this joint space, defined as the middle of its cranio-caudal extension on its lateral surface, was taken as a reference point. Ipsilateral distances (A, B, C, and D) between this point and each one of the 4 facet joints of the cervical spine up to the facet joints C2-3 were then computed. Subsequently, coronal computed tomography (CT) scans were taken to verify these distances. In a second experiment, a spinal needle was advanced under ultrasound guidance to the zygapophyseal joints from C2-3 to C6-7 on both sides of 1 cadaver. The exact placement of the needle tips was again verified by CT. RESULTS: In 4 attempts, a depiction of the joint space was not possible. Ultrasound and CT provided the same mean measurements of 1.2+/-0.2 cm, 2.0+/-0.3 cm, 3.0+/-0.2, and 4.0+/-0.5 cm for distances A, B, C, and D, respectively. All 10 needle tips were located in the joint space during simulated facet joint injections, as also verified by CT. DISCUSSION: This preclinical study suggests that ultrasound is a useful guiding tool for facet joint injections in the cervical spine.

Cervical Vertebrae↗