PubMed Health⌕ Search

Biomedical subjects

Gerda T Noordhoek

Publications and source records attributed to Gerda T Noordhoek.

3 recordsLinked to original sources

Detection of Mycobacterium tuberculosis complex with Real Time PCR: comparison of different primer-probe sets based on the IS6110 element.

The sensitivity and specificity to detect Mycobacterium tuberculosis complex of four Real Time PCR primer-probe sets was compared. Three sets targeted nearly the same location on the IS6110 sequence and set 4 targeted a location 200 bp downstream on IS6110. Real Time PCR's with sets 1, 2 and 3 were carried out with co-amplification of a modified target as an internal amplification control. By testing identical DNA samples it was shown that small changes in primer and probe sequences result in differences in the performance of the assays, regarding analytical sensitivity and specificity.

DNA Primers↗

Reliability of nucleic acid amplification methods for detection of Chlamydia trachomatis in urine: results of the first international collaborative quality control study among 96 laboratories.

The first European Quality Control Concerted Action study was organized to assess the ability of laboratories to detect Chlamydia trachomatis in a panel of urine samples by nucleic acid amplification tests (NATs). The panel consisted of lyophilized urine samples, including three negative, two strongly positive, and five weakly positive samples. Ninety-six laboratories in 22 countries participated with a total of 102 data sets. Of 204 strongly positive samples 199 (97.5%) were correctly reported, and of 506 weakly positive samples 466 (92.1%) were correctly reported. In 74 (72.5%) data sets correct results were reported on all samples, and 17 data sets (16.7%) showed either one false-negative or one false-positive result. In another 11 data sets, two or more incorrect results were reported, and two data sets reported a false-positive result on one negative sample. The Roche COBAS Amplicor test was performed in 44 (43%) data sets, the Abbott LCx assay was performed in 31 (30%) data sets, the Roche Amplicor manual assay was performed in 9 (9%) data sets, an in-house PCR was performed in 9 (9%) data sets, the Becton Dickinson ProbeTec ET assay was performed in 5 (4.9%) data sets, and the GenProbe TMA assay was performed in 4 (3.9%) data sets. The results of the Roche Amplicor manual (95.6% correct), COBAS Amplicor (97.0%), and Abbott LCx (94.8%) tests were comparable (P = 0.48). The results with the in-house PCR, BD ProbeTec ET, and GenProbe TMA tests were reported correctly in 88.6, 98, and 92.5% of the tests, respectively. Freeze-drying of clinical urine specimens proved to be a successful method for generating standardized, stable, and easy-to-transport samples for the detection of C. trachomatis by using NATs. Although the results, especially the specificity, for this proficiency panel were better than most quality control studies, sensitivity problems occurred frequently, underlining the need for good laboratory practice and reference reagents to monitor the performance of these assays.

Chlamydia Infections↗

Intercenter reproducibility of binary typing for Staphylococcus aureus.

The reproducibility of the binary typing (BT) protocol developed for epidemiological typing of Staphylococcus aureus was analyzed in a biphasic multicenter study. In a Dutch multicenter pilot study, 10 genetically unique isolates of methicillin-resistant S. aureus (MRSA) were characterized by the BT assay as presented by van Leeuwen et al. [J. Clin. Microbiol. 2001 39 (1) 328]. The BT assay, including a standardized DNA extraction protocol was performed in duplicate in eleven medical microbiology laboratories. Two different hybridization detection procedures were applied and a prelabeled DNA sample as process control was included. Only three laboratories accurately identified all strains. Divergence in technical procedures resulted in misinterpretation due to an increasing number of faint or absent hybridization signals in combination with high background staining. The binary type of the process control was determined correctly by all participating laboratories. The feasibility of the BT protocol was related directly to the skill of the laboratory personnel. On the basis of the national study, we concluded that the DNA extraction protocol needed modification to improve DNA yield and purity. Subsequently, seven European laboratories participated in an international study to determine the reproducibility of the modified BT protocol. Each center was asked to analyze 10 DNA samples previously extracted from 10 MRSA strains (phase 1) and, additionally, to analyze 10 MRSA strains, using the standardized or their in-house DNA isolation protocol (phase 2). A prelabeled DNA process control sample was included again. The binary types of all DNA samples were identified correctly by all but one laboratories. This latter laboratory diverged from the protocol by adding an excess of labeled DNA to the hybridization mixture, resulting in a high background and, therefore, noninterpretable BT results. All centers produced identical BT results for the process control. Five of the seven centers correctly identified the binary types of all 10 MRSA strains in phase 2 of the international study. Three of these centers used their in-house DNA extraction protocol. Divergence from the standard BT protocol in the remaining two centers resulted in no interpretable BT data for the 10 MRSA strains. The study demonstrated that each center that followed the BT protocol to the letter could generate reproducible results, irrespective whether or not an in-house DNA isolation protocol was used. The current BT protocol thus represents a simple method generating robust, reproducible genotype data for S. aureus strains.

Bacterial Typing Techniques↗