PubMed Health⌕ Search

Biomedical subjects

Gerhard R Wittich

Publications and source records attributed to Gerhard R Wittich.

5 recordsLinked to original sources

Image-guided 25-gauge needle biopsy for thoracic lesions: diagnostic feasibility and safety.

PURPOSE: To report our experience regarding the feasibility and safety of 25-gauge needles for biopsy of thoracic lesions. MATERIALS AND METHODS: Twenty-six patients with thoracic lesions, predominately pulmonary nodules, measuring 0.7-5.2 cm (mean, 1.6 cm) underwent biopsy with computed tomographic (n = 24), ultrasonographic (n = 1), or fluoroscopic (n = 1) guidance. Nineteen patients had severe chronic obstructive pulmonary disease (COPD), one had severe restrictive lung disease, and one had a coagulopathy; the other five patients had nonpulmonary primary tumors. Biopsy with an inner 25-gauge needle traversing an outer extrapleural coaxial cannula was performed in all patients. Cytologic quick staining was performed routinely to determine specimen adequacy and to establish a preliminary diagnosis. Complications, specimen adequacy, and need for larger specimens were evaluated. RESULTS: Adequate specimens (as determined by cytopathologists) were obtained in 24 (92%) of 26 patients, with a definitive diagnosis achieved in 23 (88%) patients during initial quick staining (17 malignant and six benign diagnoses). Two cases initially considered suspicious for malignancy were reclassified as benign (thymoma and histoplasmosis). At the request of cytopathologists, a larger needle was used to supplement the 25-gauge needle in six patients: In one patient, it provided further diagnostic information; in four, it did not; and in one, it confirmed non-Hodgkin lymphoma. Five patients developed a small pneumothorax (<10%) with use of the 25-gauge needle alone; one other patient, in whom larger needles were placed, received a radiologic chest catheter to evacuate the pneumothorax, thereby allowing the biopsy to continue. CONCLUSION: Image-guided 25-gauge needle biopsy is both feasible and safe.

Adult↗

Transosseous access for decompression of an obstructed pelvic kidney.

We report a case of an obstructed pelvic kidney which was decompressed using a transosseous access route. The patient presented with obstructive uropathy and fever, necessitating decompression. Initial access was gained to the kidney by traversing the ilium, allowing subsequent retrograde placement of a double-J ureteric catheter.

Aged↗

Salinoma window technique for mediastinal lymph node biopsy.

Computed tomographic-guided transthoracic needle biopsy can access virtually all mediastinal lymph node stations, but is limited by the potential for pneumothorax and bleeding. To avoid these possible complications, the extrapleural "salinoma" technique was used for computed tomographic-guided mediastinal biopsies in 15 patients. Sampling methods were coaxial (8), tandem (5), and single pass (2). Diagnostic yield was 93% with no significant bleeding or pneumothorax. The salinoma technique permits biopsy of deep mediastinal lesions to stage pulmonary malignancies, while providing a technique that limits complications.

Biopsy, Needle↗

Removal of a trapped endoscopic catheter from the gallbladder via percutaneous transhepatic cholecystostomy: technical innovation.

BACKGROUND: Percutaneous cholecystostomy is used for a variety of clinical problems. METHODS: Percutaneous cholecystostomy was utilized in a novel setting to resolve a problematic endoscopic situation. OBSERVATIONS: Percutaneous cholecystostomy permitted successful removal of a broken and trapped endoscopic biliary catheter, in addition to helping treat cholecystitis. CONCLUSION: Another valuable use of percutaneous cholecystostomy is demonstrated, as well as emphasizing the importance of the interplay between endoscopists and interventional radiologists.

Adult↗

Interventional radiology strategies in the treatment of pseudomyxoma peritonei.

PURPOSE: To describe percutaneous maneuvers to treat the unusual entity symptomatic pseudomyxoma peritonei (PMP). METHODS: Four patients with PMP were treated by interventional radiology techniques that included large catheters (20-30 Fr) alone (n = 3), multiple catheters (n = 4), and dextran sulfate as a catalytic agent through smaller catheters (n = 1). The causes of the PMP were tumors in the ovary (2 patients), appendix (1 patient), and colon (1 patient). Each patient previously had undergone at least two operations to remove the PMP, and all patients had symptomatic recurrence. An in vitro analysis of catalytic agents also was performed. RESULTS: All four patients improved symptomatically. Follow-up CT scans demonstrated marked reduction of PMP material in all cases. One patient underwent another interventional radiology session 5 months after the first; the other three patients had no recurrence of symptoms. One patient had reversible hypotension 2 hr after the procedure. The amount of material removed varied from 3 to 6 L. CONCLUSION: These interventional radiology techniques were effective and safe for PMP and suggest options for this difficult medical and surgical problem.

Aged↗