Impact of left atrial size reduction on chronic atrial fibrillation in mitral valve surgery.

BACKGROUND AND AIM OF THE STUDY: Left atrial enlargement is a risk factor for the development of atrial fibrillation (AF). Large atrial size increases thromboembolic risk and reduces the success rate of cardioversion. The study aim was to evaluate if left atrial size reduction affects cardiac rhythm in patients with chronic AF undergoing mitral valve surgery. METHODS: Twenty-seven patients were analyzed prospectively. The left atrial incision was extended to the left inferior pulmonary vein. Left atrial size reduction was achieved by closure of the left atrial appendage from inside with a double running suture. The same suture plicated the left lateral atrial wall to the roof of the left pulmonary vein inflow and the inferior atrial wall. The atrial septum was plicated by placing stitches of the closing suture line across the fossa ovalis. Rhythm, neurological complications, cardioversion, anticoagulation and anti-arrhythmic medication were evaluated at one year postoperatively and at recent follow up (mean 40 +/- 15 months). RESULTS: At discharge, five patients (19%) were in sinus rhythm (SR). At one year postoperatively, SR was restored in 17 patients (63%), but five (19%) reported episodes of arrhythmia and AF persisted in 10 (37%). At recent follow up, four patients had died and three were lost to follow up. Among 20 patients examined, 13 (65%) had SR but six reported episodes of arrhythmia and AF persisted in seven (35%). LA diameter was significantly reduced, from 60.2 +/- 9.8 mm preoperatively to 44.5 +/- 7.0 mm at one year after surgery. CONCLUSION: The addition of left atrial size reduction to mitral valve surgery is technically simple, and was effective in 63% of patients with chronic AF, restoring predominant SR. In order to influence pathogenetic factors other than size, additional ablative steps may further increase the SR conversion rate. Size reduction may also improve the outcome of other ablative approaches.

Adult↗

Emergent endovascular interventions for contained rupture of thoracic aortic aneurysms.

BACKGROUND: The purpose of our study was to assess in an emergency setting the feasibility of endovascular stent graft treatment of contained ruptures of thoracic aortic aneurysms. METHODS: Seven patients with contained ruptures of thoracic aortic aneurysms from a series of 54 endovascular interventions were treated by the deployment of an aortic stent graft. In all cases, hemothorax was present. Acute deployment was performed with the patient under general anesthesia, and access was gained via the common femoral or iliac arteries. After a follow-up o f 12 months, the patients were evaluated by computed tomography. RESULTS: One patient died perioperatively. The procedure was technically successful in 5 patients. Perioperatively and at follow-up, there were no cases of paraplegia, stent graft migration, or endoleaks. There were, however, 2 cases of access failure, 1 case of temporary renal failure, and 2 patients who required prolonged mechanical ventilation. CONCLUSION: The acute treatment of contained ruptures of thoracic aortic aneurysms is feasible. This form of treatment seems to be a promising option in the treatment of these high-risk patients.

Aged↗

Ultrafast computed tomography for quality control of automated proximal anastomoses.

BACKGROUND: The Symmetry aortic connector uses a nitinol implant to create proximal anastomoses with saphenous vein grafts. Multiple detector-row cardiac computed tomography (MDCT) is used as a noninvasive method of quality control at our institution. METHODS: In 50 elective coronary artery bypass grafting patients who participated in a randomized trial comparing automated with conventionally hand-sewn proximal anastomoses, MDC T was performed on postoperative day 5. Fifty-three automated Symmetry anastomoses were created in 34 patients (group 1). Twenty-five conventionally hand-sewn anastomoses created in 16 patients served as controls (group 2). Graft patency and the presence or absence of high-grade stenosis at the proximal anastomotic site were evaluated. RESULTS: In group 1, 2 (3.8%) of the grafts were found occluded at MDCT or coronary angiography, and no further relevant stenosis was observed. In group 2, at postoperative MDCT all grafts were found patent without significant narrowing of the proximal anastomotic site. CONCLUSIONS: The feasibility of proximal anastomoses using the Symmetry device has been reported. Patency control with invasive angiography has been performed by other groups. With MDCT, noninvasive evaluation of proximal anastomotic quality and graft patency is possible, even if nitinol is implanted.

Aged↗

Biventricular pacing for weaning from extracorporeal circulation in heart failure.

Resynchronization of the intra- and interventricular conduction by biventricular pacing has been suggested in patients with end-stage heart failure. We present a case in which extracorporeal circulation could only be weaned after placement of an additional left ventricular pacing wire. Biventricular stimulation led to normal motion of the anterior wall and a previously bulging interventricular septum; this improved the hemodynamic situation significantly.

Aged↗

The Heartflo device for distal coronary anastomoses: clinical experiences in 60 patients.

BACKGROUND: The Heartflo anastomotic device automates the suturing process with simultaneous delivery of 10 standard polypropylene sutures through the graft and the coronary vessel wall to construct the anastomosis. We performed clinical testing in 60 patients undergoing coronary artery bypass grafting. METHODS: One automated distal coronary anastomosis was initially placed in each patient, the other anastomoses were created with standard running sutures. After a "flat foot"-shaped prototype was deployed in 30 patients (group I), the design of the foot was modified and deployment of the new device performed in the next 30 patients (group II). RESULTS: In group I, automated anastomoses were completed in 16 patients (53%) using 1.7 +/- 1 additional stitches. In 26 group II patients (86%), a hemostatic anastomosis using 1.2 +/- 1 additional stitches was achieved. Anastomoses were completed in 19.0 +/- 3 minutes in group I and in 15.6 +/- 2 minutes in group II. CONCLUSIONS: We have shown the feasability of coronary anastomoses using the Heartflo device. The modified version improved tissue capture, resulting in a higher rate of completed anastomoses. Because anastomotic time is still prolonged, an easier suture management is mandatory in the next developmental step.

Aged↗

How safe is the port access technique in minimally invasive coronary artery bypass grafting?

BACKGROUND: This study compares conventional coronary artery bypass grafting (CABG) with port access CABG via a left anterior small thoracotomy in patients requiring surgical multivessel revascularization. Clinical, neuropsychological, and angiographic outcomes were studied, as well as parameters of myocardial and cerebral protection. Pathogenicity of cardiopulmonary bypass (CPB) was further evaluated by measuring parameters of peripheral limb ischemia and inflammatory whole-body response. METHODS: In a prospective randomized study, 40 patients who required multivessel CABG were assigned to either conventional CABG via complete median sternotomy (group A) or port access CABG via minithoracotomy (group B). Control angiograms were performed in group B only. In addition, patients underwent neuropsychological testing after the operation. CK, CK-MB, and Troponin T levels were documented. S-100B protein and neuron-specific enolase (NSE) served to quantify cerebral injury. The terminal complement complex (C5b-9) and myeloperoxidase concentrations were determined to analyze inflammatory whole-body response after CPB. RESULTS: There was no mortality. One patient suffered a retrograde aortic dissection immediately after onset of CPB, but had an uneventful postoperative course after surgical repair. Troponin T and CK-MB showed no difference between groups. CK and myoglobin were significantly higher in the minimally invasive cohort. Changes in complement activation (C5b-9) and myeloperoxidase during CPB markers of the whole-body inflammatory response were similar in both groups. S-100B concentrations in the port access group were significantly higher, whereas NSE levels were similar in both groups. Both groups did not display any significant difference in neuropsychological testing. CONCLUSIONS: Minimally invasive multivessel CABG via minithoracotomy using port access technology is feasible and safe. Though prolonged operating and CPB times with significantly higher S-100B concentrations were observed in group B, equivalent myocardial and cerebral protection and similar whole-body inflammatory response were documented.

Aged↗

Robotically enhanced placement of left ventricular epicardial electrodes during implantation of a biventricular implantable cardioverter defibrillator system.

Biventricular pacing has gained increasing acceptance in advanced heart failure patients. One major limitation of this therapy is positioning the left ventricular stimulation lead via the coronary sinus. This report demonstrates the feasibility of totally endoscopic direct placement of an epicardial stimulation lead on the left ventricle using the daVinci surgical system.

Aged↗

Segmental wall motion abnormalities during telerobotic totally endoscopic coronary artery bypass grafting.

UNLABELLED: In addition to single-lung ventilation (SLV), intrathoracic CO2 insufflation is mandatory for adequate exposure during totally endoscopic coronary artery bypass grafting. With transesophageal echocardiography, we investigated biventricular myocardial wall motion in 25 patients with isolated disease of the left anterior descending coronary artery who underwent totally endoscopic coronary artery bypass grafting with the "Da Vinci" robotic surgical system. At distinct time points during the operation, a cine loop of both ventricles was registered from a transgastric mid-short-axis view. Myocardial wall motion analysis was performed according to an established segmentation model of the left ventricle and to an established five-point scale for wall motion (1, normal; 5, dyskinesia). Significant alterations from preoperative baseline wall motion were visible in the septal, inferior, and anterior segments of the left ventricle at some time during the prebypass period, combined with a markedly decreased PaO2 under SLV and increased intrathoracic pressure. The same findings applied to the right ventricle; however, wall motion abnormalities were more pronounced here. After myocardial revascularization, weaning from cardiopulmonary bypass, CO2 deflation, and return to double-lung ventilation, myocardial wall motion recovered to baseline values. Clinically significant hemodynamic instability did not occur. The data suggest that robot-assisted coronary artery bypass grafting leads to significant prebypass alterations of biventricular segmental wall motion. On the basis of our data, it cannot be definitively stated whether the observed results were due to reduced oxygenation during SLV and thus "real" myocardial ischemia, intrathoracic CO2 insufflation with positive pressure leading to mechanical compromise of the heart, absolute or relative hypovolemia, or a combination of these factors. However, in this cohort, which consisted of patients with single-vessel disease and good ventricular function, these changes were of limited clinical relevance. IMPLICATIONS: Segmental myocardial wall motion was evaluated with transesophageal echocardiography during robot-assisted totally endoscopic coronary artery bypass grafting. Significant biventricular segmental wall motion abnormalities occurred before cardiopulmonary bypass under single-lung ventilation and carbon dioxide insufflation. The changes in myocardial wall motion were of limited clinical relevance.

Carbon Dioxide↗

Coronary artery bypass grafting through complete sternotomy in conscious patients.

BACKGROUND: Complete sternotomy is the standard approach in cardiac surgery, and coronary artery bypass grafting (CABG) is the most common revascularization procedure to use this approach. A new technique has been developed that permits complete surgical revascularization with arterial grafts in awake patients. This technique, which we refer to as awake coronary artery bypass grafting, avoids general anesthesia, mechanical ventilation, and extracorporeal circulation, thereby creating the least invasive method for heart operations yet described. METHODS: A thoracic epidural catheter was placed at T2-T3 level one day before surgery. In 12 patients, single (n = 6), double (n = 5), or triple (n = 1) vessel coronary artery bypass grafting was performed without general anesthesia. In six patients, this procedure was performed after complete median sternotomy. RESULTS: Ten patients remained awake throughout the whole procedure. Two patients required secondary intubation due to incomplete analgesia in one case and pneumothorax in the other. Procedural time was 98.2 +/- 19.8 minutes. Intermediate care stay was 4.9 +/- 0.6 hours. There were no perioperative complications, and early angiographic results before discharge were excellent in all patients. CONCLUSIONS: The data presented show the feasibility and safety of complete surgical revascularization via median sternotomy using arterial grafts without general anesthesia. This approach shortens recovery time and increases patient comfort, suggesting that outpatient cardiac surgery may eventually be possible.

Aged↗

Totally endoscopic bilateral internal thoracic artery bypass grafting in a young diabetic patient.

BACKGROUND: The introduction of robotics into cardiosurgical practice in 1998 has enabled totally endoscopic closed chest procedures. Totally endoscopic grafting of the LAD (TECAB) is no longer an experimental procedure. CASE REPORT: We report on a case with totally endoscopic bilateral internal thoracic artery bypass grafting to the left anterior descending and right coronary artery in a 36-year-old obese female diabetic patient using the daVinci surgical system. The patient, suffering from juvenile diabetes for 26 years, presented with stable angina (CCS class II). A coronary angiogram revealed 2-vessel disease with a long complex proximal lesion of the left anterior descending artery (LAD) (90%) and 80% stenosis of the proximal right coronary artery (RCA). Due to the condition of the proximal LAD (high risk PTCA with rather poor prognosis), the patient was referred for minimally invasive operative revascularisation of the LAD and the RCA. After informed consent was obtained the patient underwent totally endoscopic double internal thoracic artery bypass revascularisation on the arrested heart using computer-enhanced telemanipulation technology. RESULTS: The feasibility and safety of successful closed chest, totally endoscopic double coronary bypass grafting with two internal thoracic arteries is demonstrated in this case. Preservation of a stable chest cavity and reduced risk for wound healing complications in diabetics with an excellent cosmetic result are the obvious advantages of the techniques described.

Adult↗

Relocalization of endothelial cell beta-catenin after coculture with activated neutrophils from patients undergoing cardiac surgery with cardiopulmonary bypass.

Cardiac surgery with cardiopulmonary bypass (CPB) is associated with neutrophil activation, inflammation, and consecutive edema. The impairment of endothelial junction molecules, and thus, hyperpermeability elicited by the interaction of activated neutrophils with endothelial cells may be important in this regard. Cocultures with human endothelial cells and neutrophils from 10 cardiac surgery patients with CPB were used to evaluate the role of neutrophils in modifications of the endothelial zonula adherens molecules VE-cadherin and beta-catenin. Laser scan microscopic analyses showed that neutrophils, which were isolated after the beginning of CPB, significantly impaired intracellular redistribution of endothelial beta-catenin with regard to membrane association (p <.0002) and staining pattern (p <.0001). VE-cadherin localization was not found to be significantly modified. Western blots with total cell extracts showed that amounts of beta-catenin did not vary significantly after co-culture with activated neutrophils. Activated neutrophils during cardiac surgery with CPB may induce endothelial dysfunction by impairing beta-catenin localization and thus contribute to endothelial hyperpermeability.

Antigens, CD↗