Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument background to contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention.

Animals↗

Interventional MR angiography with a floating table.

A floating table was integrated into a setup for performance of interventional magnetic resonance (MR) angiography procedures with actively visualized catheters and biplanar real-time image fusion. The setup was evaluated by performing catheterizations in eight pigs. The floating table enabled the authors to follow actively visualized instruments in the pigs' vasculature during MR imaging-guided interventional angiography procedures while performing real-time biplanar MR imaging. Interventional MR angiography with a floating table enables the field of view to be moved along with the instrument tip to the region of interest and thus enhances the usability and flexibility of the interventional MR imaging setup.

Animals↗

Interventional MRA using actively visualized catheters, TrueFISP, and real-time image fusion.

An integrated system for performing interventional magnetic resonance angiography (MRA) with actively visualized instruments and real-time image fusion was implemented on a 1.5 T scanner. True fast imaging with steady precession (TrueFISP) imaging provided high acquisition speed paired with high signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the simultaneous visualization of active instruments and arterial morphology. The system enabled simultaneous image reconstruction and image postprocessing of multiple receiver channels, with subsequent image fusion display in real time. Optional interleaved image acquisition in two planes provided additional important information for biplanar instrument guidance. Various vascular interventions, including selective catheterization and subsequent selective MRA of the abdominal aorta, renal arteries, superior mesenteric artery (SMA), hepatic artery, and aortic arch, were performed on 10 pigs under MR guidance. In terms of instrument contrast, image acquisition, reconstruction, and fusion speed, the setup represents a powerful platform for performing interventional MRA procedures.

Animals↗

Inductively coupled stent antennas in MRI.

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material-dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B(1) fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long-term follow-up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis.