PubMed Health⌕ Search

Biomedical subjects

Gernot T John

Publications and source records attributed to Gernot T John.

9 recordsLinked to original sources

Methods and milliliter scale devices for high-throughput bioprocess design.

Based on electromagnetic simulations as well as on computational fluid dynamics simulations gas-inducing impellers and their magnetic inductive drive were optimized for stirred-tank reactors on a 10 ml-scale arranged in a bioreaction block with 48 bioreactors. High impeller speeds of up to 4,000 rpm were achieved at very small electrical power inputs (63 W with 48 bioreactors). The maxima of local energy dissipation in the reaction medium were estimated to be up to 50 W L(-1) at 2,800 rpm. Total power input and local energy dissipation are thus well comparable to standard stirred-tank bioreactors. A prototype fluorescence reader for 8 bioreactors with immobilized fluorometric sensor spots was applied for online measurement of dissolved oxygen concentration making use of the phase detection method. A self-optimizing scheduling software was developed for parallel control of 48 bioreactors with a liquid-handling system for automation of titration and sampling. It was shown on the examples of simple parallel batch cultivations of Escherichia coli with different media compositions that high cell densities of up to 16.5 g L(-1) dry cell mass can be achieved without pH-control within 5 h with a high parallel reproducibility (standard deviation<3.5%, n=48) due to the high oxygen transfer capability of the gas-inducing stirred-tank bioreactors.

Bioreactors↗

Gas sensing in microplates with optodes: influence of oxygen exchange between sample, air, and plate material.

Microplates with integrated optical oxygen sensors are a new tool to study metabolic rates and enzyme activities. Precise measurements are possible only if oxygen exchange between the sample and the environment is known. In this study we quantify gas exchange in plastic microplates. Dissolved oxygen was detected using either an oxygen-sensitive film fixed at the bottom of each well or a needle-type sensor. The diffusion of oxygen into wells sealed with different foils, paraffin oil, and paraffin wax, respectively, was quantified. Although foil covers showed the lowest oxygen permeability, they include an inevitable gas phase between sample and sealing and are difficult to manage. The use of oil was found to be critical due to the extensive shaking caused by movement of the plates during measurements in microplate readers. Thus, paraffin wax was the choice material because it avoids convection of the sample and is easy to handle. Furthermore, without shaking, significant gradients in pO2 levels within a single well of a polystyrene microplate covered with paraffin oil were detected with the needle-type sensor. Higher pO2 levels were obtained near the surface of the sample as well as near the wall of the well. A significant diffusion of oxygen through the plastic plate material was found using plates based on polystyrene. Thus, the location of a sensor element within the well has an effect on the measured pO2 level. Using a sensor film fixed on the bottom of a well or using a dissolved pO2-sensitive indicator results in pO2 offset and in apparently lower respiration rates or enzyme activities. Oxygen diffusion through a polystyrene microplate was simulated for measurements without convection--that is, for samples without oxygen diffusion through the cover and for unshaken measurements using permeable sealings. This mathematical model allows for calculation of the correct kinetic parameters.

Computer Simulation↗

Miniature bioreactors for automated high-throughput bioprocess design (HTBD): reproducibility of parallel fed-batch cultivations with Escherichia coli.

To verify the reproducibility of cultivations of Escherichia coli in novel millilitre-scale bioreactors, fully automated fed-batch cultivation was performed in seven parallel-operated ml-scale bioreactors with an initial volume of 10 ml/reactor. The process was automatically controlled by a liquid-handling system responsible for glucose feeding, titration and sampling. Atline analysis (carried out externally of the reaction vessel with a short time delay) comprised automated pH and attenuance measurements. The partial pressure of oxygen (pO2) was measured online by a novel fluorimetric sensor block measuring the fluorescence lifetime of fluorophors immobilized inside the millilitre-scale bioreactors. Within a process time of 14.6 h, the parallel cultivation yielded a dry cell weight of 36.9+/-0.9 g.l(-1). Atline pH measurements were characterized by an S.D. of <1.1% throughout the process. Computational-fluid-dynamics simulation of single-phase flow yields a mean power input of 21.9 W.l(-1) at an impeller speed of 2800 rev./min corresponding to a power number (NP) of 3.7.

Automation↗

Microplates with integrated oxygen sensors for kinetic cell respiration measurement and cytotoxicity testing in primary and secondary cell lines.

This paper presents a cytotoxicity and cell respiration assay that is nondestructive and kinetic. It makes use of 96-well microplates integrated with oxygen sensors. The oxygen signal monitored on-line gives an indication of the cell viability. We show its application for suspension cell lines (Chinese hamster ovary and HL60 cells) as well as adherent (Caco2 cells) and primary (rat hepatocytes) cells using well-known cytotoxic compounds (sodium azide, diclofenac, clozapine, sodium dodecyl sulfate, 2-thiouracil, tamoxifen, and tranylcypromine). The 50% lethality concentration (LC50) obtained from the assay is compared with the standard 3-(4,5-dimethylthiazol-2- yl)-2,5-diphenyl-2H-tetrazolium bromide end-point assay. The cells can be grown directly in the plates, and the assay requires no further reagents or processing. The cells can be harvested for further analysis, if required. The on-line dynamic measurement allows the calculation of LC50 as a function of exposure time. LC50 was shown to decrease with time in HL60 cells. The dynamics of this process was considerably different for the three compounds sodium dodecyl sulfate, tamoxifen, and diclofenac, indicating a large potential of application of this method for cell death studies. The assay system can be applied to almost any cell-based systems with little adaptation. The assay is robust, flexible, and applicable for medium- to high-throughput systems requiring only minimal handling and no additional agent.

Animals↗

Evaluation of OxoPlate for real-time assessment of antibacterial activities.

We have evaluated the OxoPlate OP96F for its usefulness in the characterization of antibacterial compounds. Each well of the plate carries two different fluorescent dyes, an oxygen-sensitive indicator dye and a reference dye. Fluorescence intensity is proportional to the amount of dissolved oxygen in the medium. Growth of bacterial cells is measured indirectly via the gradual depletion of oxygen. In this study, Bacillus subtilis was treated with 14 different antibacterials of various modes of action. The OxoPlate was not only useful to deduce MIC values directly from the oxygen-depletion curves, but was also able to discriminate bactericidal from bacteriostatic compounds. Oxygen levels of cultures treated with bactericidal compounds dropped initially and then increased after the cells had died. In contrast, oxygen levels remained low when cultures were treated with bacteriostatic compounds. The system described herein gives valuable insight into the kinetics of growth inhibition and killing, and we conclude that the OxoPlate is highly useful for the initial characterization of antibacterials.

Anti-Bacterial Agents↗

Integrated optical sensing of dissolved oxygen in microtiter plates: a novel tool for microbial cultivation.

Microtiter plates with integrated optical sensing of dissolved oxygen were developed by immobilization of two fluorophores at the bottom of 96-well polystyrene microtiter plates. The oxygen-sensitive fluorophore responded to dissolved oxygen concentration, whereas the oxygen-insensitive one served as an internal reference. The sensor measured dissolved oxygen accurately in optically well-defined media. Oxygen transfer coefficients, k(L)a, were determined by a dynamic method in a commercial microtiter plate reader with an integrated shaker. For this purpose, the dissolved oxygen was initially depleted by the addition of sodium dithionite and, by oxygen transfer from air, it increased again after complete oxidation of dithionite. k(L)a values in one commercial reader were about 10 to 40 h(-1). k(L)a values were inversely proportional to the filling volume and increased with increasing shaking intensity. Dissolved oxygen was monitored during cultivation of Corynebacterium glutamicum in another reader that allowed much higher shaking intensity. Growth rates determined from optical density measurement were identical to those observed in shaking flasks and in a stirred fermentor. Oxygen uptake rates measured in the stirred fermentor and dissolved oxygen concentrations measured during cultivation in the microtiter plate were used to estimate k(L)a values in a 96-well microtiter plate. The resulting values were about 130 h(-1), which is in the lower range of typical stirred fermentors. The resulting maximum oxygen transfer rate was 26 mM h(-1). Simulations showed that the errors caused by the intermittent measurement method were insignificant under the prevailing conditions.

Bioreactors↗

PH-sensing 96-well microtitre plates for the characterization of acid production by dairy starter cultures.

A new method for characterization of acid production by dairy starter cultures is presented. Microplates with integrated optical pH sensors are developed. Two fluorophores, a pH-sensitive and a pH-insensitive one are immobilised at the bottom of a polystyrene 96-well microtitre plate. The pH-insensitive fluorophore serves as an internal reference and makes calibration unnecessary. The sensor measures pH accurately in optically well-defined media. Particles and fluorophores contained in the bulk medium disturbed the measurements. Despite these disturbances it was possible to clearly sense differences in inoculum type and in inoculum sizes of cultures of Lactococcus lactis and of Streptococcus thermophilus at 30 and 37 degrees C. Besides a pH-related signal there is information about other changes during milk fermentation. The cultivation results were compared with those from the established CINAC-method. From this comparison it can be concluded that the new method can be used reliably to characterize particularly a large number of strains for screening purposes but also for quality control.

Animals↗

Modeling of mixing in 96-well microplates observed with fluorescence indicators.

Mixing in 96-well microplates was studied using soluble pH indicators and a fluorescence pH sensor. Small amounts of alkali were added with the aid of a multichannel pipet, a piston pump, and a piezoelectric actuator. Mixing patterns were observed visually using a video camera. Addition of drops each of about 1 nL with the piezoelectric actuator resulted in umbrella and double-disklike shapes. Convective mixing was mainly observed in the upper part of the well, whereas the lower part was only mixed quickly when using the multichannel pipet and the piston pump with an addition volume of 5 microL or larger. Estimated mixing times were between a few seconds and several minutes. Mixing by liquid dispensing was much more effective than by shaking. A mixing model consisting of 21 elements could describe mixing dynamics observed by the dissolved fluorescence dye and by the optical immobilized pH sensor. This model can be applied for designing pH control in microplates or for design of kinetic experiments with liquid addition.

Acids↗

Rapid evaluation of oxygen and water permeation through microplate sealing tapes.

Eight commercially available microplate sealing tapes and 10 other suitable materials (transparent wound dressings) are compared qualitatively in terms of their ability to minimize water evaporation from a multiwell plate while maintaining the oxygen supply as high as possible, which is necessary for applications like aerobic growth. The transparency and sterility of the products are considered as well. All evaluated commercially available sealing tapes fall into one of the following two classes: (1) O(2) transfer is comparable to that of an unsealed plate, but water vapor retention is relatively low, or (2) O(2) transfer via the sealing is slower, but the water retention capability is comparably high. All but one of the evaluated wound dressings fall under the second class. That dressing, however, constitutes a compromise by showing both moderate O(2) permeability and medium water retention. But the estimated mass transport in a microtiter plate sealed with this dressing is about 5 times slower than that of an unsealed 96 well plate. The aim of this publication is to enable the reader to choose a microtiter plate sealing from the materials evaluated within this work and to use the rapid methods described herein to easily perform tests of additional sealing materials.

Adhesives↗