PubMed Health⌕ Search

Biomedical subjects

Gero Stibenz

Publications and source records attributed to Gero Stibenz.

3 recordsLinked to original sources

C60 in intense short pulse laser fields down to 9 fs: excitation on time scales below e-e and e-phonon coupling.

The interaction of C60 fullerenes with 765-797 nm laser pulses as short as 9 fs at intensities of up to 3.7 x 10(14) W cm(-2) is investigated with photoion spectroscopy. The excitation time thus addressed lies well below the characteristic time scales for electron-electron and electron-phonon couplings. Thus, energy deposition into the system is separated from energy redistribution among the various electronic and nuclear degrees of freedom. Insight into fundamental photoinduced processes such as ionization and fragmentation is obtained from the analysis of the resulting mass spectra as a function of pulse duration, laser intensity, and time delay between pump and probe pulses, the latter revealing a memory effect for storing electronic energy in the system with a relaxation time of about 50 fs. Saturation intensities and relative abundances of (multiply charged) parent and fragment ions (C60(q+), q=1-6) are fingerprints for the ionization and fragmentation mechanisms. The observations indicate that for final charge states q>1 the well known C60 giant plasmon resonance is involved in creating ions and a significant amount of large fragments even with 9 fs pulses through a nonadiabatic multielectron dynamics. In contrast, for energetic reasons singly charged ions are generated by an essentially adiabatic single active electron mechanism and negligible fragmentation is found when 9 fs pulses are used. These findings promise to unravel a long standing puzzle in understanding C60 mass spectra generated by intense femtosecond laser pulses.

Journal Article↗

Sub-10 fs pulse characterization using spatially encoded arrangement for spectral phase interferometry for direct electric field reconstruction.

We demonstrate an extremely accurate method for measuring ultrabroadband, sub-10 fs pulses even if they exhibit a highly modulated spectrum, space-time coupling, or both. The method uses a spatially encoded arrangement for spectral phase interferometry for direct electric field reconstruction, which allows a zero additional phase measurement to be performed with a relatively low signal-to-noise ratio in real time and single shot.

Journal Article↗

Self-compression of millijoule pulses to 7.8 fs duration in a white-light filament.

We demonstrate a novel technique for pulse compression of few-millijoule pulses with shorter than 10 fs duration. Our technique relies on spectral broadening in a white-light filament generated in a noble gas. In this filament we observe self-compression of 45 fs pulses down to below 8 fs duration without the need for any additional dispersion compensation. Using input pulses of 5 mJ, we generate compressed pulses with up to 3.8 mJ pulse energy. Therefore this method is much more efficient than previously demonstrated compression schemes. The generated peak powers of more than 100 GW at a kilohertz repetition rate open up a perspective for compression of few-cycle pulses with energies well beyond the capacity of hollow-fiber compressors.

Journal Article↗