Future of high pressure liquid chromatography: do we need porosity or do we need pressure?

Making a theoretical study supported by experiments of the kinetic advantages of increased inlet pressures versus increased external porosity using impedance plots of analysis time versus required plate number, it is found that both approaches more or less have the same effect on the kinetic performance. The need to change a given system to one with an increased inlet pressure or with an increased external porosity can best be assessed from the optimal plate number (N(opt)) of the system. When the pursued application requires a plate number that is larger than N(opt), any increase in inlet pressure and external porosity is beneficial. When the required plate number is smaller than N(opt), any increase in inlet pressure and external porosity should preferentially be accompanied by an overall reduction of the feature sizes of the support. The degree to which this feature size reduction can be realized in practice will to a large extent determine which of the two approaches will be the dominant system of the future.

Chromatography, High Pressure Liquid↗

Detection enhancement in nano-channels using micro-machined silicon groove.

The present paper reports on an experimental study of the possibility to use a micro-machined detection groove to enhance the detection sensitivity in flat-rectangular nano-channels for ultra-rapid liquid chromatography separations. Transversally running detection grooves with three different axial widths (respectively, 2, 4 and 6 microm) and one depth (4.75 microm) were tested in glass and silicon channels for the whole range of detectable fluorescein isothiocyanate isomer I, FITC, concentrations. The groove with the most square-like cross-section (i.e., 4 microm wide and 4.75 microm deep) yielded the best combination of detection gain and minimal additional band broadening. In a 1cm long channel, the effective plate loss caused by the 4 microm wide groove would only be of the order of 20%, while the gain in S/N-ratio was of the order of a factor of 5. The detection groove concept yields larger gains in silicon channel substrates than in glass channel substrates, due to the larger stray light losses occurring in the latter.

Chromatography, Liquid↗

Selection of comparison criteria and experimental conditions to evaluate the kinetic performance of monolithic and packed-bed columns.

The present study concerns the problem of finding appropriate experimental conditions and comparison criteria to assess the kinetic performance of LC supports with different sizes or morphologies. A general procedure, based on evaluating each support for its own optimal mobile-phase composition, is proposed. The practical elaboration of the procedure is illustrated using the specific case of a capillary LC separation of a series of polycyclic aromatic test compounds employing silica-monolith capillary columns and capillary columns packed with 6-microm porous particles. To compare the systems for their ability to yield the fastest critical-pair separation, plate-height measurements are transformed into an effective plate number kinetic plot, i.e., a plot of the extrapolated retention time divided by the square of the extrapolated effective plate number (t(R)/N(eff)(2)) versus N(eff). This type of data representation provides a direct and universal basis to compare the kinetic performance of different LC supports and it corrects for differences in retention strength arising from different phase ratios.

Chromatography, Liquid↗

Theoretical calculation of the retention enthalpy effect on the viscous heat dissipation band broadening in high performance liquid chromatography columns with a fixed wall temperature.

The problem of the additional band broadening arising from the trans-column temperature profile under conditions of significant viscous heat dissipation has been extended by including the retention enthalpy effect. This effect can significantly aggravate the trans-column migration velocity profile of retained species as compared to the already known zero-retention enthalpy case. An approximate analytical solution for the accompanying additional band broadening could be established. The solution is valid in nearly all practically relevant cases and shows how the additional band broadening varies as a function of the generated heat, the retention coefficient and the retention enthalpy. Surveying all possible HPLC operating conditions, it was found that the inclusion of the retention enthalpy effect leads to significantly larger viscous heating plate height contributions than those predicted by the zero-retention enthalpy solution (up to a factor of 10 or more).

Chromatography, High Pressure Liquid↗

Practical constraints in the kinetic plot representation of chromatographic performance data: theory and application to experimental data.

It is demonstrated that the kinetic plot representation of experimental plate height data can also account for practical constraints on the column length, the peak width, the viscous heating, and the mobile-phase velocity without needing any iterative solution routine. This implies that the best possible kinetic performance to be expected from a given tested support under any possible set of practical optimization constraints can always be found using a directly responding calculation spreadsheet template. To show how the resulting constrained kinetic plots can be used as a powerful design and selection tool, the method has been applied to a series of plate height measurements performed on a number of different commercial columns for the same component (butyl-parabene) and mobile-phase composition. The method, for example, allows one to account for the fact that the advantageous solutions displayed by the silica monolith and 5 microm particle columns in the large plate number range of the free kinetic plot are no longer accessible if applying a maximal column length constraint of Lmax = 30 cm. In the plate number range that remains accessible, the investigated sub-2 mum particle columns in any case perform (at least for the presently considered parabene separation) better than the 3.5 mum particle columns or silica monolith, especially if considering the use of system pressures exceeding 400 bar. The constrained kinetic plot method can also be used to select the best-suited column length from an available product gamma to perform a separation with a preset number of plates. One of the optimization results that is obtained in this case is that sometimes a significant gain in analysis time can be obtained by selecting a longer column, yielding the desired plate number at a larger velocity than that for a shorter column.

Algorithms↗

A dimensionless number analysis of the hybridization process in diffusion- and convection-driven DNA microarray systems.

The present theoretical analysis aims at providing a general understanding of the combined effect the many different process variables have on the hybridization rate in diffusion- and convection-driven DNA microarray systems. It is shown that all process variables can be grouped into only four different dimensionless numbers (the Damkohler number Da, the dimensionless association constant kappa(A), the dimensionless initial concentration C'(0) and a geometrical ratio alpha). These four numbers have a straightforward physical meaning and only contain easily measurable parameters. Reducing the solution space from 7D to 4D, the dimensionless number representation greatly facilitates the insight in the conditions leading to the occurrence of diffusion-limited hybridization rates in both diffusion- and convection-driven DNA microarray systems. This in turn simplifies their design and the interpretation of the experimental results that are obtained with these systems.

Diffusion↗

Performance limits of monolithic and packed capillary columns in high-performance liquid chromatography and capillary electrochromatography.

A method is proposed for the comprehensive characterization and comparison of columns in the high-performance liquid chromatographic (HPLC) and capillary electrochromatographic (CEC) modes. Using this approach, column parameters such as the number of plates, the eddy-diffusion and mass-transfer contributions to peak broadening, the permeability, and the analysis time are incorporated in a single graph and a comparison in terms of efficiency and speed is obtained. The chromatographic performance of silica-based and polymer-based monolithic capillary columns is discussed and a comparison is made with the performance of packed columns. Also, the potential of ultra-high-pressure liquid chromatography is discussed in this context. In the HPLC mode, the best results were obtained with silica monoliths; in the CEC mode, the low-density methacrylate-ester-based monoliths showed the best performance.

Chromatography, High Pressure Liquid↗

Ultra-rapid separation of an angiotensin mixture in nanochannels using shear-driven chromatography.

The present paper reports on the separation of a mixture of fluorescein isothiocyanate-labeled angiotensin I and II peptides in a shear-driven nanochannel with a C18-coating and using an eluent consisting of 5% acetonitrile in 0.02 M aqueous phosphate buffer at pH 6.5. The flat-rectangular nanochannel in fused silica consisted of an etched structure in combination with a flat moving wall. The very fast separation kinetics that can be achieved in a nanochannel allowed to separate the angiotensin peptides in less then 0.2 s in a distance of only 1.8 mm. Plate heights as small as 0.4 microm were calculated after substraction of the injection effect.

Angiotensin I↗

Measurements of diffusion coefficients in 1-D micro- and nanochannels using shear-driven flows.

The present paper describes a method for measuring the molecular diffusion coefficient of fluorescent molecules in microfluidic systems. The proposed static shear-driven flow method allows one to perform diffusion measurements in a fast and accurate manner. The method also allows one to work in very thin (i.e. submicron) channels, hence allowing the investigation of diffusion in highly confined spaces. In the deepest investigated channels, the obtained results were comparable to the existing literature values, but when the channel size dropped below the micrometer range, a significant decrease (more than 30%) in molecular diffusivity was observed. The reduction of the diffusivity was most significant for the largest considered molecules (ssDNA oligomers with a size ranging between 25 to 100 bases), but the decrease was also observed for smaller tracer molecules (FITC). This decrease can be attributed to the interactions of the analyte molecules with the channel walls, which can no longer be neglected when the depth of the channel reaches a critical value. The change in diffusivity seems to become more explicit as the molecular weight of the analytes increases.

DNA, Single-Stranded↗

DNA microarray enhancement using a continuously and discontinuously rotating microchamber.

It is demonstrated that the most efficient way to enhance DNA microarray analysis consists of a maximal reduction of the total device volume (to keep the concentration of the available DNA as high as possible), combined with the creation of a strong lateral convective transport of the sample. In the present study, DNA microarray hybridizations are performed in a set of rotating, circular microchambers covering exactly the spotted area of the microarray and with a depth varying between 70 and 1.6 microm. Rotating the microchamber substrate while keeping the microarray stationary, the rotating microchamber bottom wall literally drags the sample past the microarray spots with a velocity which is independent of the fluid layer thickness. Interestingly, it was found that transporting the sample in a discontinuous mode (with stop periods of several minutes) not only yields a more stable and reproducible operation, it also yields significantly larger hybridization intensities (typically a factor of 2-3 larger) than a continuous rotation. This seems to be due to the fact that the velocity field disturbs the binding process at the binding site level. Working under limiting DNA sample mass conditions, the system yielded in a short, 30-min experiment already a 5-fold increase of the hybridization intensity, as compared to a conventional microscope slide/coverslip system operated overnight under diffusion-driven conditions. Compared to a commercial pump-around hybridization system, the gain was even more impressive, precisely due to the fact that the pump-around system requires larger volumes, which with a fixed amount of available genetic material leads to the application of more diluted samples.

DNA, Complementary↗

Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology.

The advantages of representing experimental plate height data as a plot of Kv/u0(2) or H2/Kv versus Kv/(Hu0) instead of as H versus u0 are discussed (Kv=column permeability). Multiplying the values on both axes by the ratio of a reference pressure drop and mobile-phase viscosity, the obtained plots directly yield the kinetic performance limits of the tested support structure, without any need for further numerical optimization. Directly showing the range of plate numbers or analysis times wherein the tested support geometry can yield faster separations or produce more plates than another support type, such kinetic plots are ideally suited to compare the performance of differently shaped or sized LC supports. The approach hence obviates the need for a common reference length, which is a clear problem if it is attempted to compare differently shaped supports on the basis of their flow resistance phi and reduced plate height h. It is also shown how an MS Excel template file, only requiring the user to paste the column permeability Kv and a series of experimental (u0, H) data, can be used to automatically establish a series of so-called kinetic performance (KP) numbers, which can be used to completely describe the performance characteristics of the considered support. The advantages of the proposed data representation methods are demonstrated by applying them to several recent literature plate height data sets, showing that the obtained kinetic plots directly visualize the range of plate numbers where new approaches such as ultra-high-pressure HPLC or the use of open-porous silica monoliths can be expected to provide a substantial gain and where not. The data analysis also showed that the most generally relevant KP numbers are N(opt) (the plate number for which the support achieves its best analysis time/pressure cost ratio), t(opt) (the time needed to obtain N(opt) plates), and t(1K) (the time needed to generate 1000 or 1 kilo of theoretical plates). These KP numbers are much more informative than the H(min), u(0,opt), and Kv data traditionally employed to quantify the performance of LC supports.

Journal Article↗

Experimental validation of the tetrahedral skeleton model pressure drop correlation for silica monoliths and the influence of column heterogeneity.

This paper describes the use of computational fluid dynamics for the calculation of the flow resistance through computer-generated models resembling silica monoliths. This study was undertaken to determine the effect of skeleton heterogeneity on the flow resistance and, more precisely, to test the hypothesis that increased skeleton heterogeneity decreases the flow resistance. To evaluate the proposed model, 24 real silica monoliths have been prepared using the same method, covering a wide range of skeleton sizes (2.2 microm < d(s) < 8 microm) and porosities (0.47 < epsilon < 0.66). The permeability of these monoliths was determined by pressure drop measurements, and structural information was obtained by image analysis of laser scanning confocal microscopy-generated 3D images of the skeleton structure. The results indicate that the presence of preferential flow paths due to an increased heterogeneity of the flow through pore space reduces the flow resistance of monolithic media. It is also shown that the pore size is hence a much better suited scaling dimension than the skeleton size to reduce the permeability of monolithic columns.

Journal Article↗

A first principles explanation for the experimentally observed increase in A-term band broadening in small domain silica monoliths and other chromatographic supports.

The present computational study illustrates how the existence of a residual lower limit on the variance of the skeleton and through-pore size of monolithic columns can be expected to severely compromise the possibility to prepare well-performing small domain monolithic columns. Adopting rather conservative estimates for the minimal standard deviation on the pore and the skeleton size (0.2 and 0.04 microm, respectively), the presented calculations show that, if such a fixed lower limit on the size variance exists, it will be impossible to decrease the A-term band broadening below a given critical value, no matter how small the domain size is made. From a given critical domain size value on, any attempt to further decrease the domain size without being able to co-reduce the size variance can be expected to be counterproductive and leads to an increase instead of to a further decrease of the plate heights.

Chromatography, Liquid↗

Comparison of a pump-around, a diffusion-driven, and a shear-driven system for the hybridization of mouse lung and testis total RNA on microarrays.

In the present study, we demonstrate the benefits of a shear-driven rotating microchamber system for the enhancement of microarray hybridizations, by comparing the system with two commonly used hybridization techniques: purely diffusion-driven hybridization under coverslip and hybridization using a fully automated hybridization station, in which the sample is pumped in an oscillating manner. Starting from the same amount of DNA for the three different methods, a series of hybridization experiments using mouse lung and testis DNA is presented to demonstrate these benefits. The gain observed using the rotating microchamber is large: both in terms of analysis speed (up to tenfold increase) and in final spot intensity (up to sixfold increase). The gain is due to the combined effect of the hybridization chamber miniaturization (leading to a sample concentration increase if comparing iso-mass conditions) and the transport enhancement originating from the rotational shear-driven flow induced by the rotation of the chamber bottom wall.

Animals↗

General rules for the optimal external porosity of LC supports.

We present a series of numerically calculated plate height and flow resistance data obtained for an idealized chromatographic support mimic with variable bed porosity (0.3 </= epsilon </= 0.9), yielding a unique insight into how the main chromatographic performance parameters can be expected to vary with the external bed porosity, unbiased by any differences in molecular diffusivity or retention factor. The influence of pore heterogeneity effects is considered as well. It is found that the product h(min)nu(opt) depends only very weakly on epsilon and on the degree of pore heterogeneity. It is also found that the minimal separation impedance E(min) decreases monotonically with epsilon. This shows that the minimal plate height increase that can be expected for large porosity systems is always more than compensated by their reduced flow resistance, in agreement with the current observations in real silica monolith columns. Using the computed plate height data in an optimization analysis, it is found that large porosity supports can always potentially yield shorter analysis times or larger plate numbers than small porosity supports but need submicrometer feature sizes to actually achieve this. Assuming a lower limit on the producible or useable structural feature sizes, it is found that small N separations can best be performed with a small porosity packing, whereas large N separations require a large porosity packing if the column length (L) is left free. A plot yielding epsilon(opt) as a function of the required plate number has been established, showing that roughly epsilon(opt) approximately log(N) in both the ordered and the disordered support cases. It is also shown that the maximal increase in peak capacity ever to be expected from the use of high porosity supports is a factor of 2 (if the mobile-phase viscosity can be kept constant), potentially to be increased by a factor of 1.5 by increasing the homogeneity of the packing.

Journal Article↗

Importance and reduction of the sidewall-induced band-broadening effect in pressure-driven microfabricated columns.

The influence of the detailed design of the sidewall region upon the over-all band-broadening in microfabricated packed-bed or collocated monolithic support structure (COMOSS) columns has been investigated using computational fluid dynamics (CFD) simulation techniques. It is shown that, under unretained solute conditions, very small structural variations of the order of only 5% of the particle diameter can give rise to a 4-fold increase of the band-broadening. A comprehensive study has been made to quantify this effect as a function of the fluid velocity, the particle diameter, the channel widths, and of course, the sidewall region design. Because the sidewall effect can be fully attributed to a mismatch between the flow rates in the column center and in the sidewall region, it is fortunately also quite straightforward to avoid it. A very simple design, yielding band-broadening values identical to that of a hypothetical sidewall-less column for all possible values of the flow velocity, the particle diameter, or the channel width is proposed.

Biotechnology↗

Theoretical comparison of the band broadening in nonretained electrically and pressure-driven flows through an ordered chromatographic pillar packing.

Using a well-validated computational fluid dynamics simulation method, based on a multi-ion transport model, a detailed analysis of the differences in band broadening between pressure-driven (PD) and electrically driven (ED) flows through perfectly ordered, identical chromatographic pillar packings has been made. It was found that, although the eddy-diffusion band-broadening contributions were nearly completely absent in the considered structure, the ED flow still yields much smaller plate heights than the PD flow. This difference could be fully attributed to the different ways in which the ED and PD velocity profiles reshape when passing through a tortuous pore structure with undulating cross section. Whereas in the PD case the parabolic tip of the band front is continually squeezed and extended each time it passes a pore constriction, the ED flow displays some kind of band front restoring mechanism, with which the fluid elements of the band front are (at least partly) laterally re-aligned after each pore constriction passage. This could be clearly visualized from a series of step-by-step images of the progression of a sharply "injected" species band moving through the packing under ED and PD conditions.

Journal Article↗