PubMed Health⌕ Search

Biomedical subjects

Gert-Peter Brüggemann

Publications and source records attributed to Gert-Peter Brüggemann.

At least 19 recordsLinked to original sources

The effect of running, strength, and vibration strength training on the mechanical, morphological, and biochemical properties of the Achilles tendon in rats.

Compared with muscle or bone, there is a lack of information about the relationship between tendon adaptation and the applied loading characteristic. The purpose of the present study was to analyze the effect of different exercise modes characterized by very distinct loading patterns on the mechanical, morphological, and biochemical properties of the Achilles tendon. Sixty-four female Sprague-Dawley rats were divided into five groups: nonactive age-matched control (AMC; n = 20), voluntary wheel running (RT; n = 20), vibration strength-trained (LVST; n = 12), high-vibration strength-trained (HVST; n = 6), and high strength-trained (HST; n = 6) group. After a 12-wk-long experimental period, the Achilles tendon was tested mechanically and the cross-sectional area, the soleus and gastrocnemius muscle mass, and mRNA concentration of collagen I, collagen III, tissue inhibitor of metalloproteinase-1 (TIMP-1), transforming growth factor-beta, connective tissue growth factor, and matrix metalloproteinase-2 was determined. Neither in the LVST nor in the HVST group could any adaptation of the Achilles tendon be detected, although the training had an effect on the gastrocnemius muscle mass in the LVST group (P < 0.05). In the HST group, the highest creep was found, but the effect was more pronounced compared with the LVST group (P < 0.05) than with the AMC group. That indicates that this was rather induced by the low muscle mass rather than by training. However, the RT group had a higher TIMP-1 mRNA concentration in the Achilles tendon in contrast to AMC group (P < 0.05), which suggests that this exercise mode may have an influence on tendon adaptation.

Achilles Tendon↗

Adaptational phenomena and mechanical responses during running: effect of surface, aging and task experience.

The goals of the study were to identify adaptational phenomena in running mechanics over a variety of surfaces due to age related changes in the muscle-tendon units (MTUs) capacities, to examine whether running experience is associated with adaptational effects on running mechanics over a variety of surfaces even at old age, and to investigate whether surface condition affects running mechanics. The investigation was executed on 30 old and 19 young including 29 runners and 20 non-active subjects. In a previous study we documented that the older had lower MTUs capacities. In the present study running mechanics were analysed as the same subjects ran at 2.7 m/s over three surfaces having different compliance. Surface condition did not affect centre of mass trajectory, duty factor or joint kinetics (P > 0.01). Older react to the reduced MTUs capacity by increasing duty factor and benefiting from a mechanical advantage for the triceps surae MTU and a lower rate of force generation on all surfaces (P < 0.01). Runners displayed lower average horizontal forces and a higher mechanical advantage for the quadriceps femoris MTU for all surfaces (P < 0.01). The results provided strong evidence on that running strategy remained essentially unchanged over a variety of surfaces. Adaptive improvements in running mechanics due to task experience were present for all surfaces and did not depend on age. We further concluded that older adults were able to recalibrate their running strategy to adjust the task effort to the reduced MTUs capacities in a feedforward control manner for a variety of mechanical environments.

Adaptation, Physiological↗

The effect of bone tunnel dilation versus extraction drilling on the initial fixation strength of press-fit anterior cruciate ligament reconstruction.

INTRODUCTION: Serial dilation of the bone tunnel has been reported to create a tighter graft-tunnel fit. It was hypothesized that a serial dilation of the femoral bone tunnel would increase the initial fixation strength in press-fit anterior cruciate ligament (ACL) reconstructive surgery. MATERIALS AND METHODS: Initial fixation strength of the femoral press-fit fixation technique was investigated in 72 porcine specimens in an ex vivo study by varying the femoral tunnel preparation technique. Extraction-drilling, tunnel dilation by 1 mm and dilation by 2.5 mm were assessed. Initial fixation strength of press-fit fixated patellar tendon-bone grafts was tested within each preparation group conducting a single cycle (and cyclic) load to failure protocol. The resulting tunnel diameter and the porcine femoral bone mineral density were determined using microradiographs and peripheral quantitative CT scans, respectively. RESULTS: Dilating a previously extraction-drilled femoral bone tunnel by 1 mm significantly enhances initial press-fit fixation strength in both single cycle and cyclic load to failure testing when compared to extraction-drilling and tunnel dilation by 2.5 mm. Due to an initial spring-back effect the resulting diameter of the femoral tunnel was underestimated by 3.3% with drilling and 6.7 and 12.2% with dilation by 1 and 2.5 mm, respectively. Volumetric trabecular bone mineral density at the site corresponding to the area of tunnel placement averaged 318 mg/cm(3). CONCLUSION: Dilating a femoral tunnel that is underdrilled by 1 mm appears to be a reasonable technical procedure in order to enhance initial fixation strength of press-fit ACL graft fixation.

Analysis of Variance↗

Contribution of muscle series elasticity to maximum performance in drop jumping.

The contribution of muscle in-series compliance on maximum performance of the muscle tendon complex was investigated using a forward dynamic computer simulation. The model of the human body contains 8 Hill-type muscles of the lower extremities. Muscle activation is optimized as a function of time, so that maximum drop jump height is achieved by the model. It is shown that the muscle series elastic energy stored in the downward phase provides a considerable contribution (32%) to the total muscle energy in the push-off phase. Furthermore, by the return of stored elastic energy all muscle contractile elements can reduce their shortening velocity up to 63% during push-off to develop a higher force due to their force velocity properties. The additional stretch taken up by the muscle series elastic element allows only m. rectus femoris to work closer to its optimal length, due to its force length properties. Therefore the contribution of the series elastic element to muscle performance in maximum height drop jumping is to store and return energy, and at the same time to increase the force producing ability of the contractile elements during push-off.

Biomechanical Phenomena↗

Influence of the muscle-tendon unit's mechanical and morphological properties on running economy.

The purpose of this study was to test the hypothesis that runners having different running economies show differences in the mechanical and morphological properties of their muscle-tendon units (MTU) in the lower extremities. Twenty eight long-distance runners (body mass: 76.8+/-6.7 kg, height: 182+/-6 cm, age: 28.1+/-4.5 years) participated in the study. The subjects ran on a treadmill at three velocities (3.0, 3.5 and 4.0 m s(-1)) for 15 min each. The V(O(2)) consumption was measured by spirometry. At all three examined velocities the kinematics of the left leg were captured whilst running on the treadmill using a high-speed digital video camera operating at 250 Hz. Furthermore the runners performed isometric maximal voluntary plantarflexion and knee extension contractions at eleven different MTU lengths with their left leg on a dynamometer. The distal aponeuroses of the gastrocnemius medialis (GM) and vastus lateralis (VL) were visualised by ultrasound during plantarflexion and knee extension, respectively. The morphological properties of the GM and VL (fascicle length, angle of pennation, and thickness) were determined at three different lengths for each MTU. A cluster analysis was used to classify the subjects into three groups according to their V(O(2)) consumption at all three velocities (high running economy, N=10; moderate running economy, N=12; low running economy, N=6). Neither the kinematic parameters nor the morphological properties of the GM and VL showed significant differences between groups. The most economical runners showed a higher contractile strength and a higher normalised tendon stiffness (relationship between tendon force and tendon strain) in the triceps surae MTU and a higher compliance of the quadriceps tendon and aponeurosis at low level tendon forces. It is suggested that at low level forces the more compliant quadriceps tendon and aponeurosis will increase the force potential of the muscle while running and therefore the volume of active muscle at a given force generation will decrease.

Adult↗

Biomechanical testing of quadriceps tendon-patellar bone grafts: an alternative graft source for press-fit anterior cruciate ligament reconstruction?

INTRODUCTION: Press-fit fixation of bone-patellar tendon-bone (BPTB) grafts in anterior cruciate ligament (ACL) reconstruction has been analyzed biomechanically in previous studies; however, the use of quadriceps tendon-patellar bone (QTPB) grafts has not been studied so far. It is hypothesized that QTPB grafts provide primary fixation strength comparable to BPTB grafts in press-fit ACL reconstruction with respect to bone plug length and loading angle. MATERIALS AND METHODS: Fifty-two QTPB grafts were harvested from fresh human cadaver knees (mean age 73.3 years) with the length of the patellar bone plug being either 15 mm (Group I) or 25 mm (Group II). The grafts were anchored within fresh porcine femora (mean age 12 months) using a press-fit fixation technique. Forty-eight specimens were loaded to failure at 10 mm/s with varying loading angles of 0 degrees , 30 degrees , and 60 degrees until failure. A microradiographic pre-post-implantation analysis was conducted on four grafts. RESULTS: The biomechanical testing showed a significant difference in the ultimate failure loads comparing Group I (mean 224+/-79.3 N) to Group II (mean 339+/-61.4 N), both showing mean ultimate failure loads to increase with rising loading angle. The predominant mode of failure was graft pullout at axial loading and tendon rupture at 60 degrees loading angle. The microradiographic analysis revealed an iatrogenic damage of the bone-tendon junction on the cancellous aspect of the bone plug in all trials, corresponding with the site of impactor placement during implantation. CONCLUSION: QTPB grafts provide a loading capability comparable to BPTB grafts in press-fit ACL reconstruction. The broad and profound area of quadriceps tendon attachment to the patellar bone plug makes graft implantation demanding.

Aged↗

Effect of different ankle- and knee-joint positions on gastrocnemius medialis fascicle length and EMG activity during isometric plantar flexion.

The purpose of this study was to provide evidence on the fact that the observed decrease in EMG activity of the gastrocnemius medialis (GM) at pronounced knee flexed positions is not only due to GM insufficiency, by examining muscle fascicle lengths during maximal voluntary contractions at different positions. Twenty-two male long distance runners (body mass: 78.5+/-6.7 kg, height: 183+/-6 cm) participated in the study. The subjects performed isometric maximal voluntary plantar flexion contractions (MVC) of their left leg at six ankle-knee angle combinations. To examine the resultant ankle joint moments the kinematics of the left leg were recorded using a Vicon 624 system with 8 cameras operating at 120 Hz. The EMG activity of GM, gastrocnemius lateralis (GL), soleus (SOL) and tibialis anterior (TA) were measured using surface electromyography. Synchronously, fascicle length and pennation angle values of the GM were obtained at rest and at the plateau of the maximal plantar flexion using ultrasonography. The main findings were: (a) identifiable differences in fascicle length of the GM at rest do not necessarily imply that these differences would also exist during a maximal isometric plantar flexion contraction and (b) the EMG activity of the biarticular GM during the MVC decreased at a pronounced flexed knee-joint position (up to 110 degrees ) despite of no differences in GM fascicle length. It is suggested that the decrease in EMG activity of the GM at pronounced knee flexed positions is due to a critical force-length potential of all three muscles of the triceps surae.

Ankle Joint↗

Reproducibility of energy parameters in the pole vault.

The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. On the basis of 3D kinematic data of the athlete and the pole and ground reaction forces measured at the end of the pole in the planting box the reproducibility of parameters that describe the energy transfer into the pole and the energy exchange between the athlete and the pole during the vault was proofed. Intraclass correlation, mean root mean square and the coefficient of variance were determined, additionally the Wilcoxon Test was applied. Parameters of the athlete's 3D total mechanical energy, e.g. initial energy and final energy, and the pole energy (maximum pole energy, energy of the pole due to compressive force and bending moment) were highly reproducible. The distribution of the energy transferred into the pole due to compressive force and bending moment, the same as the energy gain of the vaulter-pole system during the vault, which indicates the strategy of interacting with the pole, were also reproducible. With this the concept of energy exchange in the pole vault can be used to analyze the impact of training interventions, changes in movement pattern respectively, on the vaulters performance during different phases of the vault. The analysis of one trial of an athlete should be sufficient to identify changes in the athlete's interaction with the elastic pole.

Biomechanical Phenomena↗

Inevitable joint angular rotation affects muscle architecture during isometric contraction.

The purpose of this study was to quantify the influence of inevitable ankle joint motion during an isometric contraction on the measured change of the gastrocnemius medialis muscle (GM) architecture in vivo during the loading and the unloading phase. Sitting on a dynamometer subjects performed isometric maximal voluntary contractions as well as contractions induced by electrostimulation. Synchronous joint angular motion, plantarflexion moment, foot's centre of pressure and real-time ultrasonography of muscle architecture changes of the GM were obtained. During the contraction the ankle joint position altered and significantly affected the change in muscle architecture. At maximal tendon force (1094+/-323 N), the measured fascicle length overestimated the change in fascicle length due to the tendon force by 1.53 cm, while the measured pennation angle overestimated the change in pennation angle due to the tendon force by 5.5 degrees . At the same tendon force the measured fascicle length and pennation angle were significantly different between loading and unloading conditions. After correcting the values for the change in ankle joint angle no differences between the loading and the unloading phase at the same tendon force were found. Concerning the estimation of GM fascicle length-force and pennation angle-force curves during the loading and unloading phase of an isometric contraction, these findings indicate that not accounting for ankle joint motion will produce unreliable results.

Ankle Joint↗

Strain and elongation of the vastus lateralis aponeurosis and tendon in vivo during maximal isometric contraction.

The strain and elongation of the vastus lateralis (VL) tendon, tendon plus aponeurosis, and aponeurosis were examined during maximal voluntary contractions on a Biodex-dynamometer (knee angle 115 degrees , hip angle 140 degrees ) in 12 sprinters. Following a warm-up phase, the subjects were instructed to perform a gradual maximal knee extension and hold it for about 3 s. The kinematics of the leg were recorded using a Vicon 512 system with eight cameras operating at 120 Hz. Ultrasonography images were taken simultaneously from the VL myotendinous junction and the mid lateral part of the VL muscle belly. During the maximal isometric knee extensions, the knee joint rotated (13.6+/-5.9 degrees ), leading to an overestimation of the elongation of the tendinous tissues. After correcting for this, the maximal elongation of the VL tendon examined at the myotendinous junction was lower (P<0.05) than the maximal elongation of the VL tendon plus aponeurosis examined at the muscle belly (15 vs. 27 mm, respectively). The maximal estimated strains of the tendon, tendon plus aponeurosis, and aponeurosis showed no statistical differences (8+/-2%, 8+/-1%, and 7+/-2%, respectively, P>0.05). It is concluded that the strains of the human VL tendon, VL tendon plus aponeurosis, and VL aponeurosis, as estimated in vivo by two dimensional ultrasound during maximal isometric contractions, do not differ from each other. The displacement measured at a cross point in the VL muscle belly is significantly greater than that measured at the VL myotendinous junction.

Adult↗

Orthotic effect of a stabilising mechanism in the surface of gymnastic mats on foot motion during landings.

The purpose of this study was to examine two hypotheses: (a) mat hardness affects foot motion during landing; (b) the influence of a surface stabilising interface integrated in a mat on foot motion is detectable. Two studies were carried out: In the first one, six female gymnasts performed barefoot landings from different falling heights onto three mats having different hardness. In the second study, a stabilising mechanism was integrated in the surface of three new mats with different hardness. Three high speed video cameras (250Hz) captured the motion of the left leg and foot. These were modelled by means of a four rigid body system. The maximal eversion at the ankle joint was not influenced by the different mats (hard: 4.6 degrees +/-1.9 to 9.3 degrees +/-3.4, medium: 3.1 degrees +/-2.7 to 7.4 degrees +/-3.5, soft: 4.8 degrees +/-2.1 to 8.4 degrees +/-3.5). The soft mat without the stabilised surface showed higher eversion values (p<0.05) between forefoot and rearfoot (medial joint: hard: 5.1 degrees +/-3.2 to 7.3 degrees +/-3.3, medium: 6.9 degrees +/-3.1 to 7.5 degrees +/-2.9, soft: 12.7 degrees +/-4.1 to 13.4 degrees +/-3.3; lateral joint: hard: 8.5 degrees +/-3.1 to 9.7 degrees +/-1.1, medium: 9.5 degrees +/-2.6 to 11.2 degrees +/-3.3, soft: 12.1 degrees +/-2.3 to 15.7 degrees +/-3.3). For the mats with the surface stabilising interface, the different hardness did not cause any significant differences in maximal eversion values at the medial (hard: 1.5 degrees +/-3.3 to 5.5 degrees +/-4.5, medium: 1.3 degrees +/-3.5 to 5.1 degrees +/-3.6, soft: 0.7 degrees +/-4.9 to 5.4 degrees +/-4.2) nor at the lateral (hard: 11.3 degrees +/-4.2 to 17.3 degrees +/-4.2, medium: 12.3 degrees +/-4.8 to 17.1 degrees +/-3.7, soft: 11.5 degrees +/-4.6 to 17.1 degrees +/-4.3) forefoot joints. The structure of the mat and the consequent deformation hollow did not influence the kinematics of the ankle joint during landings, but it influenced the motion at the medial and the lateral forefoot joints. By means of a stabilised surface, it is possible to reduce the influence of mat deformation on the maximal eversion between forefoot and rearfoot.

Adult↗

Differences between measured and resultant joint moments during isometric contractions at the ankle joint.

The purpose of this study was to examine two hypotheses: (a) during voluntary and electrically induced isometric contractions the moments measured at the dynamometer are different from the resultant moments in the same plane around the ankle joint and (b) at a given resultant moment during electrically induced isometric contractions the ankle angle while loading is different from the ankle angle while unloading. Twenty-seven long distance runners participated in the study. All subjects performed isometric maximal voluntary contractions (MVC) and contractions induced by electrostimulation at four different ankle-knee angle combinations on a Biodex-dynamometer. The kinematics of the leg were recorded using the vicon 624 system with eight cameras operating at 120 Hz. The main findings were: (a) the resultant moment at the ankle joint and the moment measured by the Biodex-dynamometer during isometric contractions are different, (b) during a plantar flexion effort the ankle angle changes significantly, whereas the knee angle shows only small and in most cases not significant changes, and (c) at identical resultant ankle joint moments the ankle angles are different between the loading and the unloading phases. The observed differences may lead to erroneous conclusions concerning the following: (a) diagnostic of muscle architecture, (b) estimation of the moment-ankle angle relationship and (c) estimation of the strain and hysteresis of tendons and aponeuroses.

Ankle Joint↗

Characteristics of the early flight phase in the Olympic ski jumping competition.

Early flight phase (approximately 40 m) of the athletes participating in the final round of the individual large hill ski jumping competition in Salt Lake City Olympics was filmed with two high-speed pan & tilt video cameras. The results showed that jumpers' steady flight position was almost completed within 0.5s. The most significant correlation with the length of the jump was found in the angle between the skis and body (r=.714, p.001 at 1.1s after the take-off). This particular phase seemed to be important because the ski angle of attack was also related to the jumping distance at the same phase. Although the more upright ski position relative to flight path resulted in longer jumping distance, the winner of the competition had significantly lower ski position as compared to the other good jumpers. This may be due to the high altitude (>2000 m) of the ski jumping stadium in this competition. Because of the low air density, the aerodynamic forces were also low and this probably caused less skillful jumpers to lean too much forward at this phase. Maintenance of speed seemed to be emphasized in this particular competition.

Altitude↗

Changes in knee cartilage volume and serum COMP concentration after running exercise.

OBJECTIVE: Investigate the relationship between running induced joint loading at the knee, changes in cartilage volume and serum cartilage oligomeric matrix protein (COMP) concentration. DESIGN: Serum COMP levels and knee cartilage volumes of experienced runners were tested before and after running. Joint loading was determined using a biomechanical model of the lower extremity. BACKGROUND: To date no biomechanical rationale has been identified to explain the role of mechanical load in the aetiology of running injuries. METHODS: Blood samples and magnetic resonance imaging scans were taken before and following a 1h training run. Knee cartilage volume and serum COMP concentration were determined. Individual knee joint loading parameters were calculated from positional data and ground reaction forces. Electromyography was employed to quantify activity of main muscle groups crossing the knee joint. RESULTS: Changes in cartilage volume and COMP showed significant correlations. Net joint forces did not explain the differences in cartilage changes. Multiple regression revealed that resting COMP, COMP change after exercise and the time of co-activation of flexor and extensor muscles explain the variance of cartilage volume changes. CONCLUSIONS: Muscular co-activation was the main mechanical parameter related to cartilage changes. The current investigation elucidates the interaction of factors related to cartilage degeneration on an individual basis. Applications to altered loading conditions such as equipment or training methods offer an auspicious way of quantifying effects of interventions.

Adult↗

Adaptation of mechanical, morphological, and biochemical properties of the rat growth plate to dose-dependent voluntary exercise.

Mechanical loading has been shown to modulate longitudinal bone growth and cellular activity of the growth plate. Nevertheless, limited and controversial results exist regarding the effect of exercise on a physiological level on the growth plate. The present study investigated whether dose-dependent voluntary exercise has an influence on morphological, biochemical, and mechanical factors of the distal femoral growth plate of immature rats. Female growing Sprague-Dawley rats were randomly assigned to a unlimited exercise group (UE, n = 10), a limited exercise group (LE, n = 10), and a sedentary control group (CON, n = 10). The exercise groups were trained voluntarily in a running wheel for 8 weeks. The UE group could use the running wheel every time, whereas the LE group had timely restricted (50%) access. After sacrifice, the right femur was prepared for histomorphometric analysis and immunohistochemical staining of the distal growth plate. Mechanical testing was carried out on the distal growth plate of the left femur in shear direction. At the end of the study, the UE group had a significantly lower body mass than the CON group. There was no significant difference in overall femoral length between the groups. The height of the growth plate and the proliferation zone was significantly greater in the CON group than in both exercise groups. Only the LE group had a significantly lower hypertrophic zone and matrilin-3 staining pattern than the CON group. Osteonectin was located in the matrix of the upper hypertrophic zone in the UE group, whereas the LE and CON group showed more chondrocytes in the hypertrophic and lower proliferation zones stained for osteonectin, suggesting a higher level of mineralization in the growth plate of the UE group. No variations of mechanical properties of the distal femoral growth plate were detected. These results clearly demonstrate adaptations of morphology and biochemical parameters to the dose of running exercise, which do not result in significant differences in mechanical properties or bone length between the UE, LE, and CON groups.

Adaptation, Physiological↗

Differences between measured and resultant joint moments during voluntary and artificially elicited isometric knee extension contractions.

OBJECTIVE: Examine two hypotheses: (a) during isometric knee extension contractions the moment measured at the dynamometer is different from the resultant moment in the same plane around the knee joint and (b) during isometric contractions, at the same given resultant moment the knee angle while loading is different from the knee angle while unloading. DESIGN: Comparative study in which the geometrical and the kinetic differences between joint and dynamometer were determined. BACKGROUND: It is usually assumed that the moment measured by the dynamometer is equivalent to the resultant joint moment. The non-rigidity of the dynamometer-leg system can influence the equivalence of these two moments. METHOD: Twenty seven subjects performed isometric maximal knee extension contractions and contractions induced by electrostimulation on a dynamometer. The kinematics of the leg were recorded using 8 cameras (120 Hz). RESULTS: The resultant moment at the knee joint and the moment measured by the dynamometer are different. During a knee extension effort the knee angle changes significantly. At identical resultant knee joint moments the knee angles are different when comparing the loading and the unloading phases. CONCLUSIONS: The differences between the measured and the resultant joint moments might influence the estimation of parameters as: muscle forces, moment-angle relationship and strain and hysteresis of tendons and aponeuroses. RELEVANCE: Torque dynamometers have been often used to estimate muscle forces, to examine neuromuscular processes and to determine the mechanical properties of tendons and aponeuroses.

Biomechanical Phenomena↗

Effect of the pole--human body interaction on pole vaulting performance.

The purposes of this study were: (a) to examine the interactions between the athlete and the pole and the possibility for the athlete to take advantage of the pole's elasticity by means of muscular work and (b) to develop performance criteria during the interaction between the athlete and the pole in pole vaulting. Six athletes performed 4-11 trials each, at 90% of their respective personal best performance. All trials were recorded using four synchronized, genlocked video cameras operating at 50 Hz. The ground reaction forces exerted on the bottom of the pole were measured using a planting box fixed on a force plate (1000 Hz). The interaction between athlete and pole may be split into two parts. During the first part, energy is transferred into the pole and the total energy of the athlete decreases. The difference between the energy decrease of the athlete and the pole energy is an indicator of the energy produced by the athletes by means of muscular work (criterion 1). During the second part of the interaction, energy is transferred back to the athlete and the total energy of the athlete increases. The difference between the returned pole energy and the amount of energy increase of the athlete defines criterion 2. In general, the function of the pole during the interaction is: (a) store part of the kinetic energy that the athlete achieved during the run up as strain energy and convert this strain energy into potential energy of the athlete, (b) allow the active system (athlete) to produce muscular work to increase the total energy potential.

Energy Transfer↗

Effect of ankle joint position and electrode placement on the estimation of the antagonistic moment during maximal plantarflexion.

During maximal efforts, antagonistic activity can significantly influence the joint moment. During maximal voluntary "isometric" contractions, certain joint rotation can not be avoided. This can influence the estimation of the antagonistic moment from the EMG activity. Our study aimed to quantify the influence on the calculated agonistic moment produced during maximal voluntary isometric plantarflexions (a) when estimating antagonistic moments at different ankle angles and (b) when placing the EMG electrodes at different portions over the m. tibialis anterior. Ten subjects performed maximal voluntary isometric plantarflexions at 90 degrees ankle angle. In order to estimate the antagonistic moment, submaximal isometric dorsiflexions were performed at various ankle angles. Moment and EMG signals from mm. triceps surae and tibialis anterior were measured. The RMS differences between plantarflexors moment calculated considering the antagonistic cocontraction estimated at the same ankle angle at which the maximal plantarflexion moment was achieved and at different ankle angles ranged from 0.10 to 2.94 Nm. The location of the electrodes led to greater RMS differences (2.35-5.18 Nm). In conclusion, an angle 10 degrees greater than the initial plantarflexion angle is enough to minimize the effect of the change in length of the m. tibialis anterior during the plantarflexion on the estimation of the plantarflexors moment. The localisation of the electrodes over the m. tibialis anterior can influence the estimation of its cocontraction during maximal plantarflexion efforts.

Adult↗