PubMed Health⌕ Search

Biomedical subjects

Geunyoung Yoon

Publications and source records attributed to Geunyoung Yoon.

10 recordsLinked to original sources

Aberrations induced in wavefront-guided laser refractive surgery due to shifts between natural and dilated pupil center locations.

PURPOSE: To determine the aberrations induced in wavefront-guided laser refractive surgery due to shifts in pupil center location from when aberrations are measured preoperatively (over a dilated pupil) to when they are corrected surgically (over a natural pupil). SETTING: Center for Visual Science and Department of Ophthalmology, University of Rochester, Rochester, New York, USA. METHODS: Shifts in pupil center were measured between dilated phenylephrine hydrochloride (Neo-Synephrine [2.5%]) and nonpharmacological mesopic conditions in 65 myopic eyes treated with wavefront-guided laser in situ keratomileusis (Technolas 217z, Bausch & Lomb). Each patient's preoperative and 6-month postoperative wave aberrations were measured over the dilated pupil. Aberrations theoretically induced by decentration of a wavefront-guided ablation were calculated and compared with those measured 6 months postoperatively (6.0 mm pupil). RESULTS: The mean magnitude of pupil center shift was 0.29 mm +/- 0.141 (SD) and usually occurred in the inferonasal direction as the pupil dilated. Depending on the magnitude of shift, the fraction of the higher-order postoperative root-mean-square wavefront error that could be due theoretically to pupil center decentrations was highly variable (mean 0.26 +/- 0.20 mm). There was little correlation between the calculated and 6-month postoperative wavefronts, most likely because pupil center decentrations are only 1 of several potential sources of postoperative aberrations. CONCLUSIONS: Measuring aberrations over a Neo-Synephrine-dilated pupil and treating them over an undilated pupil typically resulted in a shift of the wavefront-guided ablation in the superotemporal direction and an induction of higher-order aberrations. Methods referencing the aberration measurement and treatment with respect to a fixed feature on the eye will reduce the potential for inducing aberrations due to shifts in pupil center.

Adult↗

Comparison of higher-order aberrations after wavefront-guided laser in situ keratomileusis and laser-assisted subepithelial keratectomy.

PURPOSE: To compare the higher-order aberrations (HOAs) in 70 eyes (38 patients) that had wavefront-guided laser in situ keratomileusis (LASIK) with those in 70 eyes (40 patients) that had wavefront-guided laser-assisted subepithelial keratectomy (LASEK) for the treatment of myopia. SETTING: Department of Ophthalmology, Yonsei University College of Medicine, Myongdong Bal-geun sesang Eye Clinic, and Seran Eye Center, Seoul, Korea. METHODS: In a prospective study, 140 consecutive eyes of 78 patients were treated with wavefront-guided LASIK or LASEK according to the patient's choice after each procedure had been thoroughly explained. The patients were followed for 6 months. Best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), manifest refraction, and wavefront aberrations were measured at baseline and 1, 3, and 6 months after surgery. RESULTS: There were no significant differences in postoperative BCVA, UCVA, and manifest refraction between groups. The mean root-mean-square wavefront error of HOAs for a scotopic pupil in the wavefront-guided LASIK group was significantly smaller than that in the wavefront-guided LASEK group at 1 month. Analyzing individual Zernike coefficients, the spherical aberration and second coma were significantly smaller in the wavefront-guided LASIK group than in the wavefront-guided LASEK group at 1 month. This difference in HOAs between groups disappeared at 3 and 6 months. CONCLUSIONS: The HOAs in the scotopic condition were not different between the wavefront-guided LASIK and LASEK groups beginning 3 months after surgery. However, the HOAs in the LASIK and LASEK groups had a different time course, especially in the case of spherical aberration. This finding suggests that postoperative changes in aberration contribute to the final outcome of wavefront-guided ablation.

Cornea↗

Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses.

PURPOSE: To characterize and measure the ocular aberrations in eyes implanted with monofocal intraocular lenses (IOLs) and to study any correlation between postoperative aberrations and surgical factors. METHODS: A Tscherning aberroscope was used to measure the wavefront aberrations of 62 eyes that had undergone phacoemulsification with the implantation of foldable monofocal Acrysof MA60BM IOLs (Alcon Laboratories Inc, Ft Worth, Tex). The Zernike coefficients, measured with a pupil diameter of 6 mm, were compared with those of a normal dataset of 82 eyes of healthy young myopes. RESULTS: Spherical aberration (Z(0)4) was the most predominant higher order aberration, with a mean value of 0.37 +/- 0.16 microm. A statistically significant linear relationship was noted between the magnitude of postoperative spherical aberration and the dioptric power of the IOL. The mean spherical aberration was 33 times more in the pseudophakic group than in normal young myopic eyes. The other major higher order aberrations were trefoil (Z(-3)3) with a mean of -0.13 +/- 0.22 microm and vertical coma (Z(-1)3) with a mean value of -0.11 +/- 0.23 microm. On average, the root-mean-square of higher order aberrations in pseudophakic eyes was 2.1 times that in a normal population of young myopic eyes. CONCLUSIONS: Eyes that undergo cataract surgery with monofocal IOL implantation suffer from significant higher order aberrations. The optical design of the IOL is most likely responsible for the increase in spherical aberration, the magnitude of which is a function of the dioptric power of the IOL.

Acrylic Resins↗

Measurement of wave-front aberration in soft contact lenses by use of a Shack-Hartmann wave-front sensor.

Lower- and higher-order wave-front aberrations of soft contact lenses were accurately measured with a Shack-Hartmann wave-front sensor. The soft contact lenses were placed in a wet cell filled with lens solution to prevent surface deformation and desiccation during measurements. Aberration measurements of conventional toric and multifocal soft contact lenses and a customized soft contact lens have proved that this method is reliable. A Shack-Hartmann wave-front sensor can be used to assess optical quality of both conventional and customized soft contact lenses and to assist in enhancing lens quality control.

Algorithms↗

Causes of spherical aberration induced by laser refractive surgery.

PURPOSE: To develop a corneal model to better explain how refractive surgery procedures induce spherical aberration. SETTING: Department of Ophthalmology and Center for Visual Science, University of Rochester, Rochester, New York, USA. METHODS: The preoperative cornea was modeled as a rotationally symmetric surface with various radii of curvature and asphericities. The postoperative cornea was defined as the difference between the preoperative cornea and an ablation thickness profile computed based on the Munnerlyn equation. A ray-tracing program and Zernike polynomial fitting were used to calculate the induced amount of spherical aberration assuming a fixed ablation depth per pulse or a variable ablation depth depending on the incidence angle of each pulse on the cornea. A biological eye model of the corneal surface change after laser refractive surgery was also developed to explain the induced spherical aberrations after myopic and hyperopic treatments. RESULTS: The clinical data showed that positive spherical aberration was induced after myopic correction and negative spherical aberration increased after hyperopic correction. In contrast, assuming a fixed ablation depth per pulse, the theoretical prediction was that negative spherical aberration with myopic treatment and positive spherical aberration with hyperopic treatment would increase. However, when assuming a variable ablation depth per pulse caused by non-normal incidence of laser spot on the cornea, the theoretically predicted induction of spherical aberration tends to fit better with the myopic and hyperopic clinical data. The effect of a variable ablation depth accounted for approximately half the clinically observed amount of spherical aberration. The biological model of the corneal surface change used to explain this remaining discrepancy showed the magnitude of the biological response in myopic correction is 3 times smaller than in hyperopic correction and that the direction of the biological response in hyperopic treatment is opposite that in myopic treatment. CONCLUSIONS: This nontoric eye model, which separates the effects of differences in ablation efficiency and biological corneal surface change quantitatively, explains how spherical aberration is induced after myopic and hyperopic laser refractive surgery. With the corneal topographic data, this model can be incorporated into the ablation algorithm to decrease induced spherical aberrations, improving the outcomes of conventional and customized treatments.

Computer Simulation↗

Surgeon offsets and dynamic eye movements in laser refractive surgery.

PURPOSE: To determine the amount of static and dynamic pupil decentrations that occur during laser refractive surgery. SETTING: The Center of Visual Science and the Department of Ophthalmology, University of Rochester, Rochester, New York, USA. METHODS: The surgeon's accuracy in aligning the pupil center with the laser center axis was measured when engaging the eye-tracker in 17 eyes receiving conventional laser in situ keratomileusis (LASIK) procedures (Technolas 217z; Bausch & Lomb). Eye movements were measured subsequently during the treatment in 10 eyes using a pupil camera operating at 50 Hz. Temporal power spectra were calculated from the eye movement measurements. RESULTS: The mean pupil misalignment by the surgeon at the beginning of the procedure was 206.1 microm +/- 80.99 (SD) (with respect to the laser center). The laser center was typically misaligned below (inferiorly) and to the left (nasally and temporally in left and right eyes, respectively) of the pupil [corrected] center. Small amounts of cyclotorsion were observed during the ablation (<2 degrees). The mean magnitude of dynamic pupil decentration from the laser center during treatment was 227.0 +/- 44.07 microm. The mean standard deviation of eye movements was 65.7 +/- 25.64 microm. Temporal power spectra calculated from the horizontal and vertical changes in eye position during the ablation were similar. Ninety-five percent of the total power of the eye movements was contained in temporal frequencies up to 1 Hz, on average, in both directions. CONCLUSIONS: Most eye movements during LASIK are slow drifts in fixation. An eye-tracker with a 1.4 Hz closed-loop bandwidth could compensate for most eye movements in conventional or customized ablations.

Calibration↗

Monochromatic ocular wavefront aberrations in the awake-behaving cat.

Measurement of wavefront aberrations in human eyes has become a reliable, quantitative way of assessing the optical impact of experimental and corrective ocular manipulations. Wavefront measures have also been performed in several other species, but never in cats, an animal model of choice for many ocular studies. Our goal in this study was to measure wavefront aberrations reliably in live, awake-behaving cats in a manner that is directly comparable to that used in human subjects. Six adult cats (felis cattus) were trained to fixate small targets on a computer screen. A compact Shack-Hartmann wavefront sensor was aligned with each animal's pupil center and line of sight during fixation. Wavefront images were then collected from which the cats' ocular aberrations were measured up to tenth order Zernike polynomials over a 6 mm pupil. Results show that cat and human ocular wave aberrations were very similar. Second order Zernike modes accounted for more than 90% of the total wave aberration. In agreement with our observation that cat ocular optics were comparable with those of humans, the half height width of both the cat and human higher order point spread function was about 0.95 degrees. These results form a solid basis for future wavefront sensing studies aiming to quantify the effects of ocular manipulations in experimental animals.

Animals↗

Separate effects of the microkeratome incision and laser ablation on the eye's wave aberration.

PURPOSE: To study the optical changes induced by the microkeratome cut, the subsequent laser ablation, and the biomechanical healing response of the cornea in normal laser in situ keratomileusis (LASIK) eyes. DESIGN: Prospective randomized clinical trial. METHODS: A Hansatome microkeratome was used to cut a corneal flap in one eye (study eye) of 17 normal myopic patients and a subsequent laser ablation was performed 2 months after this initial microkeratome incision. Control eyes received conventional LASIK treatments at the latter time point. The wave aberration of both the study and contralateral control eyes were measured over a 6-mm pupil with a Shack-Hartmann wavefront sensor for all preoperative, postflap cut, and postablation visits. RESULTS: The eye's higher order aberrations had a small, but significant increase (P =.03) of approximately 30% 2 months after cutting a flap. No systematic changes were observed in nearly all Zernike coefficients from their preoperative levels at 2 months postflap cut. A significant difference between the study and control eyes was observed for one trefoil mode, Z(3)(3) (P =.04). CONCLUSIONS: There was a wide variation in the response of individual Zernike modes across patients after cutting a flap. The majority of spherical aberration induced by the LASIK procedure seems to be due to the laser ablation and not the microkeratome cut. In addition, the total and higher order root mean square of wavefront errors were nearly identical for both the study and control eyes 3-months after the laser ablation, indicating that a procedure in which the incision and the ablation are separated in time to better control aberrations does not compromise the outcome of a conventional LASIK treatment.

Adult↗

Large-dynamic-range Shack-Hartmann wavefront sensor for highly aberrated eyes.

A conventional Shack-Hartmann wavefront sensor has a limitation that increasing the dynamic range usually requires sacrificing measurement sensitivity. The prototype large-dynamic-range Shack-Hartmann wavefront sensor presented resolves this problem by using a translatable plate with subapertures placed in conjugate with the lenslet array. Each subaperture is the same size as a lenslet and they are arranged so that they overlap every other lenslet position. Three translations of the plate are required to acquire four images to complete one measurement. This method increases the dynamic range by a factor of two with no subsequent change in measurement sensitivity and sampling resolution of the aberration. The feasibility of the sensor was demonstrated by measuring the higher order aberrations of a custom-made phase plate and human eyes with and without the plate.

Corneal Topography↗

Vision improvement by correcting higher-order aberrations with phase plates in normal eyes.

PURPOSE: To psychophysically demonstrate vision improvement when correcting higher-order aberrations with phase plates in normal eyes. METHODS: The wavefront aberrations of three nonsurgical normal eyes were measured with a Shack-Hartmann wavefront sensor. With these measured aberrations, phase plates were fabricated using a lathing technique. Theoretical improvement in retinal image quality was estimated by calculating the optical modulation transfer functions under the white light condition. Visual acuity measurements were also conducted to demonstrate improvement in visual performance after correcting higher-order aberrations with the phase plate. In this visual acuity measurement, a tumbling "E" with high (100%) and low (10%) contrast was used. RESULTS: The phase plate reduced the higher-order root mean square (RMS) wavefront error from 0.39 +/- 0.09 to 0.15 +/- 0.02 microm (mean +/- standard deviation from three eyes) for a 6-mm pupil. With the phase plate, retinal image quality based on the volume of modulation transfer function under 60 cycles per degree (c/deg) was improved by a factor of 1.8 +/- 0.4 over that of the eyes with spherocylindrical correction only. Average improvement in visual acuity achieved by correcting the higher-order aberration was 0.23 lines with high-contrast letters and 1.12 lines with low-contrast letters. All subjects reported subjective improvement in image quality of the letter with the phase plate. CONCLUSION: The phase plate effectively corrected the higher-order aberrations in normal eyes. As a result, both retinal image quality and visual acuity especially with the low-contrast letters were improved. This study demonstrated the feasibility of correcting higher-order aberrations and improving vision with customized optics.

Adult↗