Gianmarco F Pinton

Publications and source records attributed to Gianmarco F Pinton.

3 recordsLinked to original sources

Adaptive imaging on a diagnostic ultrasound scanner at quasi real-time rates.

Constructing an ultrasonic imaging system capable of compensating for phase errors in real-time is a significant challenge in adaptive imaging. We present a versatile adaptive imaging system capable of updating arrival time profiles at frame rates of approximately 2 frames per second (fps) with 1-D arrays and up to 0.81 fps for 1.75-D arrays, depending on the desired near-field phase correction algorithm. A novel feature included in this system is the ability to update the aberration profile at multiple beam locations for 1-D arrays. The features of this real-time adaptive imaging system are illustrated in tissue-mimicking phantoms with physical near-field phase screens and evaluated in clinical breast tissue with a 1.75-D array. The contrast-to-noise ratio (CNR) of anechoic cysts was shown to improve dramatically in the tissue-mimicking phantoms. In breast tissue, the width of point-like targets showed significant improvement: a reduction of 26.2% on average. Brightness of these targets, however, marginally decreased by 3.9%. For larger structures such as cysts, little improvement in features and CNR were observed, which is likely a result of the system assuming an infinite isoplanatic patch size for the 1.75-D arrays. The necessary requirements for constructing a real-time adaptive imaging system are also discussed.

Computer Systems↗

Continuous delay estimation with polynomial splines.

Delay estimation is used in ultrasonic imaging to estimate blood flow, determine phase aberration corrections, and to calculate elastographic images. Several algorithms have been developed to determine these delays. The accuracy of these methods depends in differing ways on noise, bandwidth, and delay range. In most cases relevant to delay estimation in ultrasonics, a subsample estimate of the delay is required. We introduce two new delay algorithms that use cubic polynomial splines to continuously represent the delay. These algorithms are compared to conventional delay estimators, such as normalized cross correlation and autocorrelation, and to another spline-based method. We present simulations that compare the algorithms' performance for varying amounts of noise, delay, and bandwidth. The proposed algorithms have better performance, in terms of bias and jitter, in a realistic ultrasonic imaging environment. The computational requirements of the new algorithms also are considered.

Algorithms↗

Rapid tracking of small displacements with ultrasound.

Time-delay estimators, such as normalized cross correlation and phase-shift estimation, form the computational basis for elastography, blood flow measurements, and acoustic radiation force impulse (ARFI) imaging. This paper examines the performance of these algorithms for small displacements (less than half the ultrasound pulse wavelength). The effects of noise, bandwidth, stationary echoes, kernel size, downsampling, interpolation, and quadrature demodulation on the accuracy of the time delay estimates are measured in terms of bias and jitter. Particular attention is given to the accuracy and resolution of the displacement measurements and to the computational efficiency of the algorithms. In most cases, Loupas' two-dimensional (2-D) autocorrelator performs as well as the gold standard, normalized cross correlation. However, Loupas' algorithm's calculation time is significantly faster, and it is particularly suited to operate on the signal data format most commonly used in ultrasound scanners. These results are used to implement a real-time ARFI imaging system using a commercial ultrasound scanner and a computer cluster. Images processed with the algorithms are examined in an ex vivo liver ablation study.

Algorithms↗