PubMed Health⌕ Search

Biomedical subjects

Gianpiero DeMonte

Publications and source records attributed to Gianpiero DeMonte.

3 recordsLinked to original sources

Effect of different ankle- and knee-joint positions on gastrocnemius medialis fascicle length and EMG activity during isometric plantar flexion.

The purpose of this study was to provide evidence on the fact that the observed decrease in EMG activity of the gastrocnemius medialis (GM) at pronounced knee flexed positions is not only due to GM insufficiency, by examining muscle fascicle lengths during maximal voluntary contractions at different positions. Twenty-two male long distance runners (body mass: 78.5+/-6.7 kg, height: 183+/-6 cm) participated in the study. The subjects performed isometric maximal voluntary plantar flexion contractions (MVC) of their left leg at six ankle-knee angle combinations. To examine the resultant ankle joint moments the kinematics of the left leg were recorded using a Vicon 624 system with 8 cameras operating at 120 Hz. The EMG activity of GM, gastrocnemius lateralis (GL), soleus (SOL) and tibialis anterior (TA) were measured using surface electromyography. Synchronously, fascicle length and pennation angle values of the GM were obtained at rest and at the plateau of the maximal plantar flexion using ultrasonography. The main findings were: (a) identifiable differences in fascicle length of the GM at rest do not necessarily imply that these differences would also exist during a maximal isometric plantar flexion contraction and (b) the EMG activity of the biarticular GM during the MVC decreased at a pronounced flexed knee-joint position (up to 110 degrees ) despite of no differences in GM fascicle length. It is suggested that the decrease in EMG activity of the GM at pronounced knee flexed positions is due to a critical force-length potential of all three muscles of the triceps surae.

Ankle Joint↗

Inevitable joint angular rotation affects muscle architecture during isometric contraction.

The purpose of this study was to quantify the influence of inevitable ankle joint motion during an isometric contraction on the measured change of the gastrocnemius medialis muscle (GM) architecture in vivo during the loading and the unloading phase. Sitting on a dynamometer subjects performed isometric maximal voluntary contractions as well as contractions induced by electrostimulation. Synchronous joint angular motion, plantarflexion moment, foot's centre of pressure and real-time ultrasonography of muscle architecture changes of the GM were obtained. During the contraction the ankle joint position altered and significantly affected the change in muscle architecture. At maximal tendon force (1094+/-323 N), the measured fascicle length overestimated the change in fascicle length due to the tendon force by 1.53 cm, while the measured pennation angle overestimated the change in pennation angle due to the tendon force by 5.5 degrees . At the same tendon force the measured fascicle length and pennation angle were significantly different between loading and unloading conditions. After correcting the values for the change in ankle joint angle no differences between the loading and the unloading phase at the same tendon force were found. Concerning the estimation of GM fascicle length-force and pennation angle-force curves during the loading and unloading phase of an isometric contraction, these findings indicate that not accounting for ankle joint motion will produce unreliable results.

Ankle Joint↗

Differences between measured and resultant joint moments during isometric contractions at the ankle joint.

The purpose of this study was to examine two hypotheses: (a) during voluntary and electrically induced isometric contractions the moments measured at the dynamometer are different from the resultant moments in the same plane around the ankle joint and (b) at a given resultant moment during electrically induced isometric contractions the ankle angle while loading is different from the ankle angle while unloading. Twenty-seven long distance runners participated in the study. All subjects performed isometric maximal voluntary contractions (MVC) and contractions induced by electrostimulation at four different ankle-knee angle combinations on a Biodex-dynamometer. The kinematics of the leg were recorded using the vicon 624 system with eight cameras operating at 120 Hz. The main findings were: (a) the resultant moment at the ankle joint and the moment measured by the Biodex-dynamometer during isometric contractions are different, (b) during a plantar flexion effort the ankle angle changes significantly, whereas the knee angle shows only small and in most cases not significant changes, and (c) at identical resultant ankle joint moments the ankle angles are different between the loading and the unloading phases. The observed differences may lead to erroneous conclusions concerning the following: (a) diagnostic of muscle architecture, (b) estimation of the moment-ankle angle relationship and (c) estimation of the strain and hysteresis of tendons and aponeuroses.

Ankle Joint↗