PubMed Health⌕ Search

Biomedical subjects

Gilbert C Walker

Publications and source records attributed to Gilbert C Walker.

11 recordsLinked to original sources

Microfluidic production of biopolymer microcapsules with controlled morphology.

We report a microfluidic approach to generating capsules of biopolymer hydrogels. Droplets of an aqueous solution of a biopolymer were emulsified in an organic phase comprising a cross-linking agent. Polymer gelation was achieved in situ (on a microfluidic chip) by diffusion-controlled ionic cross-linking of the biopolymer, following the transfer of the cross-linking agent from the continuous phase to the droplets. Gelation was quenched by collecting particles in a large pool of cross-linking agent-free liquid. The structure of microgels (from capsules to gradient microgels to particles with a uniform structure) was controlled by varying the time of residence of droplets on the microfluidic chip and the concentration of the cross-linking agent in the continuous phase. We demonstrated the encapsulation of a controlled number of polystyrene beads in the microgel capsules. The described approach was applied to the preparation of capsules of several polysaccharides such as alginate, kappa-carrageenan, and carboxymethylcellulose.

Capsules↗

Field localization in very small aperture lasers studied by apertureless near-field microscopy.

Localized surface plasmon polaritons (SSPs) have been observed on very small aperture lasers using apertureless near-field microscopy. Fields around multiple apertures are shown to result from interferences of SPP point sources at each aperture and optical fields. The near-field optical pattern around a single aperture indicates the interference of SPPs with their scattered counterparts. Near-field measurements also confirmed a preferred orientation of the rectangular aperture waveguide for the signal localization in very small aperture lasers.

Journal Article↗

Viscoelastic response of poly(dimethylsiloxane) in the adhesive interaction with AFM tips.

As follow-up to a previous study,(1) the viscoelastic response of cross-linked poly(dimethylsiloxane) (PDMS) in the adhesive interaction with AFM tips is reported. The indentation of the AFM tip into the polymer caused by adhesion is monotonically dependent on the loading speed. During the unloading process, the adherence force between the AFM tip and the polymer has a turning point at a specific unloading speed. It is found that the viscoelastic relaxation processes in the bulk polymer, which may have more than one component, cause the monotonic rate dependence of the adhesion-induced indentation; the competition between the bulk relaxation and the interfacial relaxation results in the turning point of the adherence force at a specific ramp speed. Experiments at different dwell times provide additional evidence for the existence of material relaxation. Methyl- and hydroxyl-functionalized AFM tips were used to study PDMS samples and indicated strong dipolar attractions formed at the tip-sample interface.

Adsorption↗

Ferrocenylundecanethiol self-assembled monolayer charging correlates with negative differential resistance measured by conducting probe atomic force microscopy.

Electrical and mechanical properties of metal-molecule-metal junctions formed between Au-supported self-assembled monolayers (SAMs) of electroactive 11-ferrocenylundecanethiol (FcC(11)SH) and a Pt-coated atomic force microscope (AFM) tip have been measured using a conducting probe (CP) AFM in insulating alkane solution. Simultaneous and independent measurements of currents and bias-dependent adhesion forces under different applied tip biases between the conductive AFM probe and the FcC(11)SH SAMs revealed reversible peak-shaped current-voltage (I-V) characteristics and correlated maxima in the potential-dependent adhesion force. Trapped positive charges in the molecular junction correlate with high conduction in a feature showing negative differential resistance. Similar measurements on an electropassive 1-octanethiol SAM did not show any peaks in either adhesion force or I-V curves. A mechanism involving two-step resonant hole transfer through the occupied molecular orbitals (MOs) of ferrocene end groups via sequential oxidation and subsequent reduction, where a hole is trapped by the phonon relaxation, is proposed to explain the observed current-force correlation. These results suggest a new approach to probe charge-transfer involving electroactive groups on the nanoscale by measuring the adhesion forces as a function of applied bias in an electrolyte-free environment.

Journal Article↗

Force microscopy studies of fibronectin adsorption and subsequent cellular adhesion to substrates with well-defined surface chemistries.

Molecular force spectroscopy was used to study the mechanical behavior of plasma fibronectin (FN) on mica, gold, poly(ethylene glycol), and -CH(3), -OH, and -COOH terminated alkanethiol self-assembled monolayers. Proteins were examined at two concentrations, one resulting in a saturated surface with multiple intermolecular interactions referred to as the aggregate state and another resulting in a semiaggregate state where the proteins were neither completely isolated nor completely aggregated. Modeling of the force-extension data using two different theories resulted in similar trends for the fitted thermodynamic parameters from which insight into the protein's binding state could be obtained. Aggregated proteins adsorbed on hydrophobic surfaces adopted more rigid conformations apparently as a result of increased surface denaturation and tighter binding while looser conformations were observed on more hydrophilic surfaces. Studies of FN in a semiaggregate state showed heterogeneity in the model's thermodynamic parameters suggesting that, in the early stages of nonspecific adsorption, multiple protein conformations exist, each having bound irreversibly to the substrate. Proteins in this state all demonstrated a more rigid conformation than in the corresponding aggregate studies due to the greater number of substrate contacts available to the protein. Finally, the force spectroscopy experiments were examined for any biocompatibility correlation by seeding substrates with human umbilical vascular endothelial cells. As predicted from the models used in this work, surfaces with aggregated FN promoted cellular deposition while surfaces with FN in a semiaggregate state appeared to hinder cellular deposition and growth. The atomic force microscope's use as a means for projecting surface biocompatibility, although requiring additional testing, does look promising.

Adsorption↗

Conjugated thiol linker for enhanced electrical conduction of gold-molecule contacts.

Single-molecule electrical conduction studies are used to evaluate how the molecular linking unit influences the tunneling efficiency in metal-molecule-metal (m-M-m) junctions. This work uses conducting-probe atomic force microscopy (CP-AFM) to compare the molecular conduction of two pi-bonded molecules: one with a single thiol linker, and another with a conjugated double thiol linker at both ends of the molecules. The results demonstrate that the molecule with conjugated double thiol linkers displays higher conduction in gold-molecule-gold junctions than nonconjugated single thiol-gold contacts.

Journal Article↗

Quantifying adhesion bond parameters to distinguish interactions of hydrophilic and hydrophobic blocks of polystyrene-poly-2-vinylpyridine with a silicon nitride surface.

An analysis of the loading rate dependence of the forces required to rupture an AFM tip from a block copolymer surface has provided insight into the structure of the surface-macromolecule contact, differentiation of the block contacting the tip, a measure of the polymer-surface binding energy, and the rigidity of the contact. Polystyrene-poly-2-vinylpyridine block copolymers were studied adsorbing to silicon nitride. Polystyrene makes stiff van der Waals contact with the silicon nitride surface in aqueous solution, while the bond of poly-2-vinylpyridine to the surface is more flexible and may involve a bridging water.

Journal Article↗

Using the adhesive interaction between atomic force microscopy tips and polymer surfaces to measure the elastic modulus of compliant samples.

An atomic force microscope (AFM) method for measuring surface elasticity based on the adhesive interactions between an AFM tip and sample surfaces is introduced. The method is particularly useful when there is a large adhesion between the tip and soft samples, when the indentation method would be less accurate. For thin and soft samples, this method will have much less interference from the substrate than is found using the indentation method because there is only passive indentation induced by tip-sample adhesion; in contrast, a large indentation with a sharp tip in the sample may break its stress-strain linearity, or even make it fracture. For the case where it is difficult to accurately locate the tip-sample contact point, which is problematic for the indentation method, the method based on adhesive interactions is helpful because it does not require locating the tip-sample contact point when fitting the whole retraction force curve. The model is tested on PDMS polymers with different degrees of cross-linking.

Journal Article↗

Surface elastic modulus of barnacle adhesive and release characteristics from silicone surfaces.

The properties of barnacle adhesive on silicone surfaces were studied by AFM indentation, imaging, and other tests and compared to the barnacle shear adhesion strength. A multilayered structure of barnacle adhesive plaque is proposed based on layered modulus regions measured by AFM indentation. The fracture of barnacles from PDMS surfaces was found to include both interfacial and cohesive failure of barnacle adhesive plaque, as determined by protein staining of the substratum after forced barnacle release from the substrate. Data for freshly released barnacles showed that there was a strong correlation between the mean Young's modulus of the outermost (softest) adhesive layer (E<0.3 MPa) and the shear strength of adhesion, but no correlation for other higher modulus regions. Linear, quadratic, and Griffith's failure criterion (based on rough estimate of crack length) regressions were used in the fit, and showed significance.

Adhesives↗

Application of scanning force and near field microscopies to the characterization of minimally adhesive polymer surfaces.

This mini-review reports efforts to develop new scanning probe microscopies to characterize the function and aging of textured, minimally adhesive polymer surfaces used for antifouling applications in the marine environment. Novel atomic force and infrared near field microscopy techniques have been used to characterize the polymer surface adhesion and structural properties. These techniques may find promise for characterizing the deposition of the extracellular matrix of organisms as well as aging of the polymer coating itself. The reported work is part of a larger effort to reduce biofouling on ships' hulls through the development and use of improved coating materials.

Adhesiveness↗

Noncovalent engineering of carbon nanotube surfaces by rigid, functional conjugated polymers.

We report a new nonwrapping approach to noncovalent engineering of carbon nanotube surfaces by short, rigid functional conjugated polymers, poly(aryleneethynylene)s. Our technique not only enables the dissolution of various types of carbon nanotubes in organic solvents, which represents the first example of solubilization of carbon nanotubes via pi-stacking without polymer wrapping, but could also introduce numerous neutral and ionic functional groups onto the carbon nanotube surfaces.

Journal Article↗