PubMed Health⌕ Search

Biomedical subjects

Gilbert M Brown

Publications and source records attributed to Gilbert M Brown.

8 recordsLinked to original sources

Optically directed molecular transport and 3D isoelectric positioning of amphoteric biomolecules.

We demonstrate the formation of charged molecular packets and their transport within optically created electrical force-field traps in a pH-buffered electrolyte. We call this process photoelectrophoretic localization and transport (PELT). The electrolyte is in contact with a photoconductive semiconductor electrode and a counterelectrode that are connected through an external circuit. A light beam directed to coordinates on the photoconductive electrode surface produces a photocurrent within the circuit and electrolyte. Within the electrolyte, the photocurrent creates localized force-field traps centered at the illuminated coordinates. Charged molecules, including polypeptides and proteins, electrophoretically accumulate into the traps and subsequently can be transported in the electrolyte by moving the traps over the photoconductive electrode in response to movement of the light beam. The molecules in a single trap can be divided into aliquots, and the aliquots can be directed along multiple routes simultaneously by using multiple light beams. This photoelectrophoretic transport of charged molecules by PELT resembles the electrostatic transport of electrons within force-field wells of solid-state charge-coupled devices. The molecules, however, travel in a liquid electrolyte rather than a solid. Furthermore, we have used PELT to position amphoteric biomolecules in three dimensions. A 3D pH gradient was created in an electrolyte medium by controlling the illumination position on a photoconductive anode where protons were generated electrolytically. Photoelectrophoretic transport of amphoteric molecules through the pH gradient resulted in accumulation of the molecules at their apparent 3D isoelectric coordinates in the medium.

Animals↗

Perchlorate isotope forensics.

Perchlorate has been detected recently in a variety of soils, waters, plants, and food products at levels that may be detrimental to human health. These discoveries have generated considerable interest in perchlorate source identification. In this study, comprehensive stable isotope analyses (37Cl/35Cl and 18O/17O/16O) of perchlorate from known synthetic and natural sources reveal systematic differences in isotopic characteristics that are related to the formation mechanisms. In addition, isotopic analyses of perchlorate extracted from groundwater and surface water demonstrate the feasibility of identifying perchlorate sources in contaminated environments on the basis of this technique. Both natural and synthetic sources of perchlorate have been identified in water samples from some perchlorate occurrences in the United States by the isotopic method.

Journal Article↗

Sorption and desorption of perchlorate and U(VI) by strong-base anion-exchange resins.

This study investigated the sorption affinity and capacity of six strong-base anion-exchange (SBA) resins for both uranium [U(VI)] and perchlorate (ClO4-) in simulated groundwater containing varying concentrations of sulfate (SO4(2-)). Additionally, desorption of U(VI) from spent resins was studied to separate U(VI) from resins with sorbed ClO4- for waste segregation and minimization. Results indicate that all SBA resins investigated in this study strongly sorb U(VI). The gel-type polyacrylic resin (Purolite A850) showed the highest sorption affinity and capacityfor U(VI) butwasthe least effective in sorbing ClO4-. The presence of SO4(2-) had little impact on the sorption of U(VI) but significantly affected the sorption of ClO4-, particularly on monofunctional SBA resins. A dilute acid wash was found to be effective in desorbing U(VI) but ineffective in desorbing ClO4- from bifunctional resins (Purolite A530E and WBR109). A single wash removed approximately 75% of sorbed U(VI) but only approximately 0.1% of sorbed ClO4- from the bifunctional resins. On the other hand, only 21.4% of sorbed U(VI) but approximately 34% of sorbed ClO4- was desorbed from the Purolite A850 resin. This study concludes that bifunctional resins could be used effectively to treatwater contaminated with ClO4- and traces of U(VI), and dilute acid washes could minimize hazardous wastes by separating sorbed U(VI) from ClO4- prior to the regeneration of the spent resin loaded with ClO4-.

Anion Exchange Resins↗

Photon-driven nanomechanical cyclic motion.

Microcantilevers modified by a monolayer of azobenzene molecules bend up and down periodically, switched by a 365 nm UV light, as a result of the conversion of the two configurations of azobenzene molecules in the monolayer.

Journal Article↗

Detection of femtomolar concentrations of HF Using an SiO(2) microcantilever.

Femtomolar concentrations of hydrogen fluoride, a decomposition component of nerve agents, were detected using a SiO(2) microcantilever. The microcantilever underwent bending due to the reaction of HF with SiO(2). The microcantilever deflection increased as the concentration of HF increased. Other acids, such as HCl, had no effect on the deflection of the cantilever. The mechanism of reaction-induced bending and the correlation of microcantilever deflection with the HF concentration are discussed. The deflection in response to HF of a commercially available silicon cantilever was also studied, and its response was compared with that of the SiO(2) cantilever. Much less bending amplitude and sensitivity were observed for the silicon cantilever.

Biosensing Techniques↗

Detection of CrO4(2-) using a hydrogel swelling microcantilever sensor.

Hydrogels containing various mounts of tetraalkylammonium salts were used to modify microcantilevers for measurements of the concentration of CrO4(2-) in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various CrO4(2-) concentrations as a result of swelling or shrinking of the hydrogels. The microcantilever deflection as a function of the concentration of CrO4(2-) ions is nearly linear in most concentration ranges. It was found that a concentration of 10(-11) M CrO4(2-) can be detected using this technology in a fluid cell. Other ions, such as Br-, HPO4(2-), and NO3-, have minimal effect on the deflection of this cantilever. The anions SO4(2-) and CO3(2-) could interfere with the CrO4(2-) detection, but only at high concentrations (> 10(-5) M). Such hydrogel-coated microcantilevers could potentially be used to prepare microcantilever-based chemical and biological sensors when molecular recognition agents are immobilized in the hydrogel.

Journal Article↗

Complete degradation of perchlorate in ferric chloride and hydrochloric acid under controlled temperature and pressure.

Despite favorable thermodynamics, the reduction of perchlorate (ClO4-) is kinetically limited in aqueous media because of its high activation energy. In this paper, a new methodology has been presented for degrading ClO4- in an FeCl3-HCl solution at an elevated temperature (< 200 degrees C) and/or pressure (approximately 20 atm). Results indicate that the rate constant for the pseudo-first-order reaction between ClO4- and ferrous Fe(II) (in excess) increased nearly 3 orders of magnitude when the temperature was increased from 110 to 195 degrees C, and a complete reduction of ClO4- occurred in < 1 h at 195 degrees C in the FeCl3-HCl solution. The activation energy of the reaction was calculated to be about 120 kJ/mol. Additionally, a flow-through reactor was constructed based on the batch kinetic measurements, and a nearly complete degradation of ClO4- was observed under continuous-flow mode. Because the FeCl3-HCl solution has been successfully used in regenerating selective anion-exchange resins sorbed with ClO4- during water treatment, this new methodology offers a cost-effective means to degrade ClO4- while not altering the chemical properties of the FeCl3-HCl regenerant solution so it can be reused, eliminating the production of secondary wastes.

Anion Exchange Resins↗

Detection of Hg2+ using microcantilever sensors.

Trace amounts of Hg2+ are detected by using a microcantilever coated with gold. The microcantilever undergoes bending due to accumulation of Hg2+ on the gold surface. It is found that a concentration of 10(-11) M Hg2+ can be detected using this technology. Other cations, such as K+, Na+, Pb2+, Zn2+, Ni2, Cd2+, Cu2+, and Ca2+ have little or no effect on the deflection of the cantilever. The selectivity of the Hg2+ sensor could be improved by coating the gold surface of microcantilever with a self-assembled monolayer of a long-chain thiol compound.

Adsorption↗