PubMed Health⌕ Search

Biomedical subjects

Gildas Marin

Publications and source records attributed to Gildas Marin.

3 recordsLinked to original sources

Simulated optical performance of custom wavefront soft contact lenses for keratoconus.

PURPOSE: Outstanding improvements in vision can theoretically be expected using contact lenses that correct monochromatic aberrations of the eye. Imperfections in such correction inherent to contact lenses are lens flexure, translation, rotation, and tear layer effects. The effects of pupil size and accommodation on ocular aberration may cause further difficulties. The purpose of this study was to evaluate whether nonaxisymmetric soft contact lenses could efficiently compensate for higher-order aberrations induced by keratoconus and to what extent rotation and translation of the lens would degrade this perfect correction. METHODS: Height topography data of nine moderate to severe keratoconus corneas were obtained using the Maastricht Shape Topographer. Three-dimensional ray tracing was applied to each elevation topography to calculate aberrations in the form of a phase error mapping. The effect of a nonaxisymmetric soft contact lens tailored to the corneal aberrations was simulated by adding an opposite phase error mapping that would theoretically compensate all corneal-induced optical aberrations of the keratoconus eyes. Translation (0.25, 0.5, 0.75, and 1.0 mm) and rotation (2.5 degrees, 5.0 degrees, 7.5 degrees, and 10 degrees ) mismatches were introduced. The modulation transfer function (MTF) of each eye with each displaced correction and with various pupil sizes (3, 5, and 7 mm) was deduced from the residual phase error mapping. A single performance criterion (mtfA) was calculated as the area under the MTF over a limited spatial frequency range (5 to 15 periods per degree). Finally, the ratio (RmtfA) of corrected mtfA over uncorrected mtfA provided an estimate of the global enhancement in contrast sensitivity with the customized lens. RESULTS: The contrast improvement ratios RmtfA with perfectly located lenses were for an average pupil size of 4.5 mm between 6.5 and 200. For small translation errors (0.25 mm), RmtfA ranged between 2 and 7. The largest lens translation tested (1 mm) often resulted in poorer performance than without correction (RmtfA <1). More than threefold improvements were achieved with any of the angular errors experimented. RmtfA values showed significant variations for pupil diameters between 3 and 7 mm. CONCLUSIONS: Three-dimensional aberration-customized soft contact lenses may drastically improve visual performance in patients with keratoconus. However, such lenses should be well positioned on the cornea. In particular, translation errors should not exceed 0.5 mm. Angular errors appeared to be less critical. It is further questioned whether the visual system is able to adapt to variations in optical performance of the correction in situ due to lens positioning and pupil size.

Contact Lenses, Hydrophilic↗

Optimising RGP lens fitting in normal eyes using 3D topographic data.

PURPOSE: To analyse, retrospectively, the effect of fitting characteristics on comfort of wear and the role that 3D topographic data can play in attaining an optimal lens fit with rigid gas permeable (RGP) contact lenses in normal eyes. METHODS: Included were 60 normal myopic eyes (1.00-5.00 D) with astigmatism limited to 2.00 D. Lenses were ordered empirically, based on traditional fitting rules. RESULTS: The initial fit based on traditional computation was accepted in 40% of the eyes. To achieve an acceptable fit, 15% of the eyes needed an adaptation of the back optic zone radius, in 28% switching from a multicurve to an aspheric lens design was indicated and in 17% a non-rotational symmetric lens design was favoured. The reason for changing the lens parameters could in 88% be attributed to mid-peripheral differences between corneal shape as found with 3D corneal topography. Average comfort of wear improved statistically significantly (chi(2), P<0.05) from 5.2 initially to 7.7 after 3 months in the group with optimal lens fits, while comfort slightly decreased (not significant) in the group with sub-optimal fits. Switching to a non-rotational symmetric lens design, when indicated, improved comfort significantly (chi(2), P<0.05) from 5.0 to 7.3. CONCLUSION: In normal eyes, the measurement of corneal shape, especially in the mid-peripheral regions, is of importance to optimise RGP lens fit. Optimised lens fits increases comfort of wear.

Journal Article↗

Aberration generation by contact lenses with aspheric and asymmetric surfaces.

PURPOSE: We explored the potential of aberration correction in the human eye by using a new generation of soft contact lenses with aspheric and asymmetric surfaces. METHODS: Soft contact lens samples were designed with one asymmetrical surface (front) and one spherical (back) to produce predetermined amounts of desired pure defocus, astigmatism, trefoil, coma, and spherical aberration. Contact lens wavefront aberrations were measured ex vivo using a Fizeau-Tolanski interferometer and compared with the in vivo wavefronts obtained by subtracting the aberrations of the eye with and without the contact lenses. These second set of measurements were obtained using a Shack-Hartmann sensor. RESULTS: We found that an aberration-free contact lens sample induced in the eye a small amount of residual aberration. We obtained a good match between the ex vivo and in vivo wavefront measurements for most of the samples of the contact lenses. CONCLUSIONS: The aberrations generated by soft contact lenses on the eye were predictable. Rotations and translations of the contact lenses with respect to correct position on the eye were, however, the main limitation for precise correction of the ocular aberrations.

Adult↗