A new concept of integrated cardiopulmonary bypass circuit.

OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.

Animals↗

[ECMO and cardiopulmonary support].

ECMO (extracorporeal membrane oxygenation) may be viewed as a prolonged cardiopulmonary bypass allowing for a prolonged cardio-respiratory support. Since its introduction in the 60's, its indication has expanded from acute respiratory failure to acute cardiac failure refractory to conventional treatments. The target group involves mainly those patients presenting with a cardiogenic shock following cardiac surgery or acute myocardial infarction. The advantages of this form of circulatory support, when compared with long-term ventricular assist devices, are its less invasive aspect, its ease of implantation and its reduced cost. However, its main limitation lies in its limited duration of 7 to 10 days, in particular because of hemorrhage complications. Currently, ECMO provides a temporary hemodynamical stability in order to perform an invasive cardiac treatment (coronary bypass or percutaneous dilatation), or to assess the eligibility of the patient for a long-term ventricular assist device, which will enable to wait for the availability of an allograft. The latter scenario is crucial nowadays because of the severe lack of organ donors, which is the leading cause of death among patients waiting for a heart transplant.

Cardiac Output, Low↗