Accuracy and rate of coronary artery segment visualization with CT angiography for the non-invasive detection of coronary artery stenoses.

OBJECTIVES: To evaluate CT coronary angiography (CTA) when compared with catheter coronary angiography (CCA), for the detection of coronary artery stenoses and rate of optimal coronary artery segment visualization. METHOD: Retrospective, two-center study enrolling 26 patients who underwent CCA and ECG-gated 16-detector CTA (slice thickness 0.6 mm; rotation 500 ms). RESULTS AND CONCLUSION: 283 segments were available for postprocessing. Sensitivity, specificity, and positive predictive value were, respectively, 80, 100, and 100%, for detecting more than 50% luminal stenoses, when optimally visualized segments were considered, in comparison to CCA. Negative predictive value was excellent (98%). Rate of non-optimally visualized coronary segments was 26%. Most clinical benefits of coronary CT angiography should probably be obtained when it is performed to exclude significant stenoses on selected populations of patients with a low pre-test probability of severe coronary artery disease, and under optimal conditions of controlled heart rate and minimal presence of calcium.

Aged↗

Optimization of spatial resolution for peripheral magnetic resonance angiography.

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Constriction, Pathologic↗

Nitrogen-rich coatings for promoting healing around stent-grafts after endovascular aneurysm repair.

Complications following endovascular aneurysm repair (EVAR) are related to deficient healing around the stent-graft (SG). New generations of SG with surface properties that foster vascular repair could overcome this limitation. Our goal was to evaluate the potential of a new nitrogen-rich plasma-polymerised biomaterial, designated PPE:N, as an external coating for polyethylene terephtalate (PET)- or polytetrafluoro-ethylene (PTFE)-based SGs, to promote healing around the implant. Thin PPE:N coatings were deposited on PET and PTFE films. Then, adhesion, growth, migration and resistance to apoptosis of vascular smooth muscle cells (VSMCs) and fibroblasts, as well as myofibroblast differentiation, were assessed in vitro. In another experimental group, chondroitin sulphate (CS), a newly described mediator of vascular repair, was added to normal culture medium, to search for possible additional benefit. PPE:N-coatings, especially on PET, increased and accelerated cell adhesion and growth, compared with control PET and with standard polystyrene culture plates (PCP). PPE:N was also found to increase the resistance to apoptosis in VSMC, an important finding as aneurysms are characterised by VMSC depletion caused by a pro-apoptotic phenotype. Addition of CS in solution further increased migration and resistance to apoptosis. In conclusion, PPE:N-coating and/or CS could promote vascular repair around SGs following EVAR.

Aneurysm↗

Effect of radioactivity on stent-graft incorporation after endovascular treatment of aneurysms: An animal study.

Poor stent-graft (SG) incorporation into the vessel wall, following endovascular repair of abdominal aortic aneurysms (EVAR), can lead to endoleaks and SG migration. Low-dose radiation can prevent aneurysm recurrence after coil embolization, and has been associated with a "paradoxical" increase in neointima formation after stenting in a few studies. It was hypothesized that in situ beta radiation emitted from SG could improve its incorporation by preventing the persistence of circulating channels between the implant and the vessel wall and increasing neointima formation around the SG. Phosphorus 32 ((32)P, 200 or 400 kBq per SG (n = 6 each)) was ion implanted on the external surface of balloon-expandable SGs. Twelve radioactive and six non-radioactive SGs were deployed in iliac arteries of nine Mongrel dogs. Neointima formation inside the graft and the persistence of circulating flow through an artificial groove created during the endovascular procedure were assessed by follow-up imaging and by blinded, computerized histomorphometric analysis after animal sacrifice at 3 months. Occlusion occurred in four radioactive SGs. A lesser number of patent grooves was observed along high-activity SGs than along control SGs (1/3 versus 4/4). No difference in neointima formation was observed in radioactive and non-radioactive SGs. Alteration of external graft surface was observed after ion implantation. Ion implantation of (32)P on SGs does not seem to be a viable strategy to improve incorporation and prevent type-I endoleak after EVAR.

Aneurysm↗

Influence of multiple stenoses on echo-Doppler functional diagnosis of peripheral arterial disease: a numerical and experimental study.

The objective of this paper was to evaluate the ability of the peak systolic velocity ratio (PSVR) and pressure drop (DeltaP) to detect and grade multiple stenoses in lower limb mimicking arteries. Numerical simulations and experiments in vascular phantoms allowing ultrasound duplex scanning and pressure measurements were used to investigate simple and double stenotic arterial segments. Inter-stenotic distance, severity of the distal stenosis, flow rate and flow profile (steady or pulsatile) were the tested parameters. The three-dimensional simulations considered the turbulent two-equation Wilcox model. Agreements were observed between the experimental and numerical results for DeltaP and PSVR. The maximum PSVR along the artery was shown to be mainly influenced by the severity of the most important stenosis. However, mutual interactions of both stenoses on hemodynamics were noted. By using the clinical PSVR threshold used to diagnose critical lesions (PSVR > or = 2), its longitudinal evolution along the artery poorly reflected the length of the lesion or the impact of surrounding stenoses. This investigation confirms the interaction between adjacent stenoses on hemodynamics and its impact on the Doppler ultrasound index PSVR.

Animals↗

Contrast-induced nephropathy in patients with chronic kidney disease undergoing computed tomography: a double-blind comparison of iodixanol and iopamidol.

BACKGROUND: Based on a single clinical trial, it has been suggested that the contrast agent iodixanol, which is isotonic to human plasma, may be less nephrotoxic than other nonionic contrast agents in renally impaired patients after intra-arterial injection. We compared the effects on renal function of iopamidol-370 injection (796 mOsm/kg) and iodixanol-320 (290 mOsm/kg) in patients with chronic kidney disease undergoing contrast-enhanced multidetector computed tomography (CE-MDCT) examinations using a multicenter, double-blind, randomized, parallel-group design. METHODS: A total of 166 patients with stable moderate-to-severe chronic kidney disease (screening and baseline serum creatinine, SCr, > or =1.5 mg/dL and/or creatinine clearance, CrCl, < or =60 mL/min) who were undergoing CE-MDCT of the liver or peripheral arteries were randomized to receive equi-iodine IV doses (40 gI) of either iopamidol-370 (370 mgI/mL) or iodixanol-320 (320 mgI/mL) at 4 mL/s. SCr and CrCl were obtained at screening, baseline, and at 48-72 +/- 6 hours after dose (mean, 57.4 hours). Contrast-induced nephropathy (CIN) was defined as an absolute increase > or =0.5 mg/dL (44.2 micromol/L) and/or a relative increase in SCr > or =25% from baseline. RESULTS: A total of 153 patients were included in the final analysis (13 patients excluded because of lack of follow-up, hemodialysis to remove contrast, average daily CrCl variation >1% at screening). The 2 study groups were comparable with regard to age, gender distribution, the presence of diabetes, concomitant medications, hydration, and contrast dose. Mean predose SCr was 1.6 +/- 0.4 mg/dL in both groups (P = 0.9). An absolute increase > or =0.5 mg/dL (44.2 micromol/L) in SCr was observed in none of the patients receiving iopamidol-370 and in 2.6% (2/76) of patients receiving iodixanol-320 (95% confidence interval -6.2, 1.0, P = 0.2). A relative increase > or =25% in SCr occurred in 4% (3/77) of patients receiving iopamidol-370 and in 4% (3/76) of the patients receiving iodixanol-320 (95% confidence interval -6.2, 6.1, P = 1.0). CONCLUSION: The rate of CIN was similarly low in risk patients after intravenous administration of iopamidol-370 or iodixanol-320 for CE-MDCT.

Adult↗

Endovascular embolization of symptomatic arteriovenous fistulas secondary to lower-limb in situ venous bypass grafts.

PURPOSE: To evaluate the safety and efficacy of endovascular treatment of symptomatic arteriovenous (AV) fistulas associated with femoropopliteal in situ venous bypass grafts. MATERIALS AND METHODS: Twenty-one patients underwent embolization of symptomatic AV fistulas associated with lower-limb bypass with use of the saphenous vein (n = 16) or femoral vein (n = 5). The procedures were performed with microcatheters and metallic coils. Indications for embolization were venous congestion (n = 15) and arterial insufficiency (n = 6). Eight patients had persistent lower-limb edema, seven had painful inflammatory skin thickening, three had intermittent claudication, and three had nonhealing ulcers. RESULTS: Forty-four AV fistulas were embolized. Symptoms of venous congestion regressed completely in 12 of 15 patients (80%). Partial symptom improvement was achieved in three other patients (20%), two of whom had persistent lower-limb edema and bypass with use of the femoral vein. Five of six patients with ischemic symptoms (83%) had complete symptom relief. One patient (17%) whose ischemic ulcer did not recover despite successful embolization of AV fistulas required an amputation 4 months later. Overall, 17 of 21 patients (81%) showed complete recovery of clinical symptoms. There was no bypass occlusion during follow-up (mean, 17.5 months; range, 1-45 months). CONCLUSIONS: Embolization of symptomatic AV fistulas secondary to lower-limb in situ venous bypass is a safe and efficient alternative to surgical ligature. Complete regression of clinical symptoms is less likely when the bypass is performed with use of the femoral vein.

Aged↗

Bronchial artery embolization in adults with cystic fibrosis: impact on the clinical course and survival.

PURPOSE: Although bronchial artery embolization (BAE) is effective in the acute control of recurrent or major hemoptysis in adults with cystic fibrosis, outcomes after embolization are not well known. The objective of this retrospective study was to evaluate respiratory function, survival, and hemoptysis-free survival in adult patients with cystic fibrosis treated for hemoptysis with BAE. MATERIALS AND METHODS: Of 297 patients with cystic fibrosis hospitalized from 1990 to 2004, 30 patients (mean age, 26.7+/-9.2 years) presented with major or persistent hemoptysis that required 42 BAE sessions. These patients were compared with a control group of 27 patients without hemoptysis requiring embolization who were matched for age, sex, and forced expiratory volume in 1 second (FEV1). RESULTS: Hemoptysis stopped within 24 hours after BAE in 96.6% of patients (n=29), and there were no major complications. The change in the slope of FEV1 after the BAE or matching date was significantly worse in the embolization group (P=.0007). At last follow-up, nine and one patients, respectively, had undergone lung transplantation in the BAE and control groups (P=.002). The 5-year survival rates without lung transplantation were 31% and 84%, respectively, in the BAE and control groups (hazard ratio, 5.95; P=.002). Sixty-two percent of patients were free of hemoptysis 5 years after BAE. The number of collateral arteries was the only factor associated with the risk of death or recurrent hemoptysis (P=.001). CONCLUSIONS: Despite the effectiveness of embolization in controlling recurrent or major hemoptysis, adults with cystic fibrosis who have undergone BAE for hemoptysis are at much higher risk of respiratory function aggravation, death, and the need for lung transplantation than those who have not undergone BAE for hemoptysis. They are more likely to die or to undergo lung transplantation than to present with recurrent major hemoptysis.

Adult↗

Intravascular ultrasound image segmentation: a three-dimensional fast-marching method based on gray level distributions.

Intravascular ultrasound (IVUS) is a catheter based medical imaging technique particularly useful for studying atherosclerotic disease. It produces cross-sectional images of blood vessels that provide quantitative assessment of the vascular wall, information about the nature of atherosclerotic lesions as well as plaque shape and size. Automatic processing of large IVUS data sets represents an important challenge due to ultrasound speckle, catheter artifacts or calcification shadows. A new three-dimensional (3-D) IVUS segmentation model, that is based on the fast-marching method and uses gray level probability density functions (PDFs) of the vessel wall structures, was developed. The gray level distribution of the whole IVUS pullback was modeled with a mixture of Rayleigh PDFs. With multiple interface fast-marching segmentation, the lumen, intima plus plaque structure, and media layers of the vessel wall were computed simultaneously. The PDF-based fast-marching was applied to 9 in vivo IVUS pullbacks of superficial femoral arteries and to a simulated IVUS pullback. Accurate results were obtained on simulated data with average point to point distances between detected vessel wall borders and ground truth <0.072 mm. On in vivo IVUS, a good overall performance was obtained with average distance between segmentation results and manually traced contours <0.16 mm. Moreover, the worst point to point variation between detected and manually traced contours stayed low with Hausdorff distances <0.40 mm, indicating a good performance in regions lacking information or containing artifacts. In conclusion, segmentation results demonstrated the potential of gray level PDF and fast-marching methods in 3-D IVUS image processing.

Algorithms↗

Implant degradation and poor healing after endovascular repair of abdominal aortic aneurysms: an analysis of explanted stent-grafts.

PURPOSE: To study explanted stent-grafts to achieve a better understanding of the mechanisms of failure after endovascular treatment of abdominal aortic aneurysms (AAA). METHODS: Twelve stent-grafts were harvested at autopsy (n=3) or during surgical conversion (n=9). Device alterations were investigated by macroscopic examination, radiography, and surface analysis techniques. Healing around the implants was studied via histology and immunohistochemistry, with particular attention to the stent-graft/tissue interface. RESULTS: Degradation was more important with Vanguard stent-grafts (off the market) than with AneuRx and Talent stent-grafts, but rupture of nitinol wires and poor surface finish in Talent stent-grafts raise concern about their corrosion resistance and long-term stability. Poor healing was observed around stent-grafts even after several years of implantation, with absence of vascular smooth muscle cells, fibroblasts, and collagen formation. In addition to the well-known foreign body reaction around the graft, numerous polymorphonuclear cells characteristic of the first step of healing were present in tissues around stent-grafts retrieved at surgical conversion. Factors explaining the lack of tissue organization around stent-grafts are discussed. CONCLUSION: The long-term stability of implants remains a concern and requires more transparency from manufacturers regarding the surface properties of their devices. Lack of neointima formation impairs biological fixation of the implant to the vessel wall, leading to possible endoleaks and migration. New-generation stent-grafts promoting biological fixation should be developed to improve clinical outcomes of this minimally invasive treatment.

Aged↗

Endothelial stress induces the release of vitamin D-binding protein, a novel growth factor.

Endothelial cells (EC) under stress release paracrine mediators that facilitate accumulation of vascular smooth muscle cells (VSCM) at sites of vascular injury. We found that medium conditioned by serum-starved EC increase proliferation and migration of VSCM in vitro. Fractionation of the conditioned medium followed by mass spectral analysis identified one bioactive component as vitamin D-binding protein (DBP). DBP induced both proliferation and migration of VSMC in vitro in association with increased phosphorylation of ERK 1/2. PD 98059, a biochemical inhibitor of ERK 1/2, abrogated these proliferative and migratory responses in VSMC. DBP is an important carrier for the vitamin-D sterols, 25-hydroxyvitamin-D, and 1alpha,25-dihydroxyvitamin-D. Both sterols inhibited the activity of DBP on VSMC, suggesting that vitamin D binding sites are important for initiating the activities of DBP on VSMC. Release of DBP at sites of endothelial injury represents a novel pathway favoring accumulation of VSMC at sites of vascular injury.

Amino Acid Sequence↗

External beam radiation to prevent restenosis after superficial femoral artery balloon angioplasty.

BACKGROUND: Femoropopliteal percutaneous transluminal angioplasty (PTA) remains limited by restenosis. Although vascular brachytherapy may be effective in reducing restenosis, external beam radiation would be more practical to administer after PTA. METHODS AND RESULTS: After femoropopliteal PTA without stent placement, 99 patients were randomly assigned to 0 Gy (placebo; n=24), 7 Gy (n=24), 10.5 Gy (n=26), or 14 Gy (n=25) of external beam radiation of the PTA site (with a 3-cm margin at both extremities) in 1 session 24 hours after PTA. The primary end point was minimum lumen diameter on quantitative angiography 1 year after PTA. One year after PTA, the mean minimum lumen diameter was 1.92, 1.64, 1.92, and 2.91 mm, respectively, for the 0-, 7-, 10.5-, and 14-Gy groups (P=0.0072 for 0 versus 14 Gy). Mean luminal loss was 1.14, 1.27, 1.08, and 0.14 mm, respectively, for the 4 groups (P=0.0072 for 0 versus 14 Gy). Restenosis >50% was present in 50%, 65%, 48%, and 25% of patients, respectively, for the 0-, 7-, 10.5-, and 14-Gy groups (P=0.072). At 18 months, repeated revascularizations were required in 25% of patients in the 0-Gy group versus 12% of patients in the 14-Gy group (P=0.24). CONCLUSIONS: A single session of external beam radiation of 14 Gy of the femoropopliteal angioplasty site significantly reduces restenosis at 1 year.

Aged↗

Automatic 3D segmentation of intravascular ultrasound images using region and contour information.

Intravascular ultrasound (IVUS) produces images of arteries that show the lumen in addition to the layered structure of the vessel wall. A new automatic 3D IVUS fast-marching segmentation model is presented. The method is based on a combination of region and contour information, namely the gray level probability density functions (PDFs) of the vessel structures and the image gradient. Accurate results were obtained on in-vivo and simulated data with average point to point distances between detected vessel wall boundaries and validation contours below 0.105 mm. Moreover, Hausdorff distances (that represent the worst point to point variations) resulted in values below 0.344 mm, which demonstrate the potential of combining region and contour information in a fast-marching scheme for 3D automatic IVUS image processing.

Algorithms↗

3D elastic registration of vessel structures from IVUS data on biplane angiography.

RATIONALE AND OBJECTIVES: Planar angiograms and intravascular ultrasound (IVUS) imaging provide important insight for the evaluation of atherosclerotic diseases and blood flow abnormalities. The construction of realistic three-dimensional models is essential to efficiently follow the progression of arterial plaque. This requires an explicit localization of IVUS frames from angiograms. Because of the difficulties encountered when trying to track the position of an IVUS transducer, we propose an elastic registration approach that relies on a virtual catheter path. MATERIALS AND METHODS: Deformable surface models of the lumen and external wall are constructed from segmented IVUS contours. A crude registration is obtained using a three-dimensional vessel centerline, reconstructed from two calibrated angiograms. Robust optimization of the virtual catheter path, position, absolute orientation, and regulation of the external wall shape is performed until near-perfect alignment of the back-projected silhouettes on image edges is reached. RESULTS: Visual assessment of the reconstructed vessels showed a good superposition of virtual models on the angiograms. We measured a 0.4-mm residual error value. A preliminary study of convergence properties on 15 datasets showed that initial absolute orientation may affect the solution. However, for follow-ups, coherent solutions were found among datasets. CONCLUSION: The advantages of the virtual catheter path approach are demonstrated. Future work will look at ways to single out the true solution with a better use of the available information in both modalities and additional validation studies on improved datasets.

Algorithms↗

Pain and quality of life assessment after endovascular versus open repair of abdominal aortic aneurysms in patients at low risk.

PURPOSE: To compare functional autonomy, quality of life (QOL), and pain control after endovascular and open repair (OR) of abdominal aortic aneurysms. MATERIALS AND METHODS: Forty patients with a low surgical risk profile and anatomic compatibility for stent-graft therapy were randomized to receive OR or endovascular aneurysm repair (EVAR). Technical and clinical success as well as mortality were assessed in both groups and compared by Kaplan-Meier analysis. Functional autonomy and QOL were assessed by Karnofsky score and Short Form 36 (SF-36) questionnaire. Pain control was assessed by a numeric rating scale and Brief Pain Inventory questionnaire. QOL outcomes by means of the SF-36 and pain questionnaires were compared with use of mixed-effects models for repeated-measures analysis. RESULTS: All procedures were technically successful in both groups. Three late clinical failures requiring surgical conversion or repeated intervention were observed in the EVAR group and one was observed in the OR group. There was no significant difference between groups in terms of functional autonomy or QOL. No difference in pain level was evident during the early postoperative period, whereas the pain level was lower in the OR group after 1 month. Opioid analgesic drug consumption was significantly greater in the OR group during the postoperative period. Mean hospitalization duration was shorter in the EVAR group than in the OR group (4.5 days +/- 2.4 vs 11.5 days +/- 8.1; P= .001). CONCLUSION: EVAR has no advantage over OR in patients at low risk in terms of functional autonomy, QOL, and pain control. However, EVAR was associated with shorter hospitalization durations compared with OR.

Aged↗

The Jonas study: evaluation of the retrievability of the Cordis OptEase inferior vena cava filter.

PURPOSE: To evaluate the success, safety, and efficacy of the retrieval of the OptEase Permanent/Retrievable Vena Cava Filter (Cordis, Warren, NJ), when implanted for temporary protection against venous thromboembolism. MATERIALS AND METHODS: This prospective, multicenter, non-randomized study enrolled 27 patients who needed temporary protection against pulmonary embolism in whom the intent at the time of filter insertion was retrieval of the OptEase filter. Patients presented with deep venous thrombosis (n = 17), pulmonary embolism (PE) (n = 6), and high risk for PE without thromboembolic disease (n = 4). Assessments included duplex sonography of the access site performed within 24 hours of device implantation and retrieval. All patients underwent cavography before and after filter placement and filter retrieval. Contrast-enhanced computed tomography (CT) of the abdomen and clinical follow-up was performed at 1 month after device retrieval. RESULTS: Of the 27 enrolled patients, 21 patients (77.8%) met the criteria for retrieval and all 21 patients (100%) had filters successfully retrieved with no associated adverse events. Retrieval was not attempted in six patients as a result of ongoing contraindication to anticoagulation (n = 3), large trapped thrombi within the filter (n = 2), and poor patient prognosis (n = 1). Time to retrieval ranged from 5 to 14 days with a mean implantation time of 11.1 days +/- 1.82. No symptomatic pulmonary embolism, vena cava wall injury, vena cava stenosis, significant bleeding, filter fracture, or filter migration was observed. Nineteen of the 21 patients (90.5%) were followed for 1-month post-retrieval with no device-related adverse events or symptomatic PE. Caval patency was documented in 18 of these 19 patients with CT. Two patients were lost to follow-up, and one patient refused to undergo CT examination. CONCLUSION: The OptEase permanent/retrievable vena cava filter can be safely and successfully retrieved up to 14 days in patients who no longer require inferior vena cava filter protection against pulmonary embolism.

Adult↗

Diagnosis and treatment of renovascular hypertension: a cost-benefit analysis.

OBJECTIVE: We sought to evaluate and compare the relative cost-benefit of Doppler sonography, MR angiography, and captopril-enhanced renal scintigraphy as techniques for predicting a patient's clinical response to renal angioplasty. MATERIALS AND METHODS: Estimations of positive and negative predictive values of baseline and captopril-enhanced renal scintigraphy and Doppler sonography examinations for predicting a favorable outcome after renal angioplasty were based on a previously published prospective study involving 74 patients who underwent this treatment. For gadolinium-enhanced MR angiography, predictive values were calculated from a subpopulation of 57 of these 74 subjects. The value of different combined strategies with these techniques for predicting clinical success after angioplasty was evaluated in this population. The costs of investigation and treatment per improved patient were calculated for each imaging technique and for combined strategies in a hypothetic 1,000-patient population with a 30% prevalence of renal artery stenosis, relying on the diagnostic performance reported in the literature for each technique in detecting renal artery stenosis. RESULTS: The costs for each improved patient were $12,579 for patients selected on the basis of a positive finding on Doppler sonography (false-negative results = 12/1,000) and $10,149 for patients selected with criteria combining a positive finding on Doppler sonography with a bilateral resistive index of less than 0.75 (false-negative results = 32/1,000). Patient selection based on a positive finding on MR angiography cost $18,119 (false-negative results = 0), whereas the cost of patient selection based on a positive finding on renal scintigraphy was $12,939 (false-negative results = 29/1,000). CONCLUSION: Doppler sonography is more cost-efficient but less sensitive than MR angiography for identifying patients with renovascular hypertension. MR angiography should be favored in hypertensive patients who are resistant to medical therapy to avoid false-negative examinations.