Effects of electrode design and configuration on channel interactions.

A potential shortcoming of existing multichannel cochlear implants is electrical-field summation during simultaneous electrode stimulation. Electrical-field interactions can disrupt the stimulus waveform prior to neural activation. To test whether speech intelligibility can be degraded by electrical-field interaction, speech recognition performance and interaction were examined for three Clarion electrode arrays: the pre-curved, enhanced bipolar electrode array, the enhanced bipolar electrode with an electrode positioner, and the Hi-Focus electrode with a positioner. Channel interaction was measured by comparing stimulus detection thresholds for a probe signal in the presence of a sub-threshold perturbation signal as a function of the separation between the two simultaneously stimulated electrodes. Correct identification of vowels, consonants, and words in sentences was measured with two speech strategies: one which used simultaneous stimulation and another which used sequential stimulation. Speech recognition scores were correlated with measured electrical-field interaction for the strategy which used simultaneous stimulation but not the strategy which used sequential stimulation. Higher speech recognition scores with the simultaneous strategy were generally associated with lower levels of electrical-field interaction. Electrical-field interaction accounted for as much as 70% of the variance in speech recognition scores, suggesting that electrical-field interaction is a significant contributor to the variability found across patients who use simultaneous strategies.

Adult↗

Speech recognition with amplitude and frequency modulations.

Amplitude modulation (AM) and frequency modulation (FM) are commonly used in communication, but their relative contributions to speech recognition have not been fully explored. To bridge this gap, we derived slowly varying AM and FM from speech sounds and conducted listening tests using stimuli with different modulations in normal-hearing and cochlear-implant subjects. We found that although AM from a limited number of spectral bands may be sufficient for speech recognition in quiet, FM significantly enhances speech recognition in noise, as well as speaker and tone recognition. Additional speech reception threshold measures revealed that FM is particularly critical for speech recognition with a competing voice and is independent of spectral resolution and similarity. These results suggest that AM and FM provide independent yet complementary contributions to support robust speech recognition under realistic listening situations. Encoding FM may improve auditory scene analysis, cochlear-implant, and audiocoding performance.

Cochlear Implants↗

Speech and melody recognition in binaurally combined acoustic and electric hearing.

Speech recognition in noise and music perception is especially challenging for current cochlear implant users. The present study utilizes the residual acoustic hearing in the nonimplanted ear in five cochlear implant users to elucidate the role of temporal fine structure at low frequencies in auditory perception and to test the hypothesis that combined acoustic and electric hearing produces better performance than either mode alone. The first experiment measured speech recognition in the presence of competing noise. It was found that, although the residual low-frequency (<1000 Hz) acoustic hearing produced essentially no recognition for speech recognition in noise, it significantly enhanced performance when combined with the electric hearing. The second experiment measured melody recognition in the same group of subjects and found that, contrary to the speech recognition result, the low-frequency acoustic hearing produced significantly better performance than the electric hearing. It is hypothesized that listeners with combined acoustic and electric hearing might use the correlation between the salient pitch in low-frequency acoustic hearing and the weak pitch in the envelope to enhance segregation between signal and noise. The present study suggests the importance and urgency of accurately encoding the fine-structure cue in cochlear implants.

Acoustic Stimulation↗

Contribution of frequency modulation to speech recognition in noise.

Cochlear implants allow most patients with profound deafness to successfully communicate under optimal listening conditions. However, the amplitude modulation (AM) information provided by most implants is not sufficient for speech recognition in realistic settings where noise is typically present. This study added slowly varying frequency modulation (FM) to the existing algorithm of an implant simulation and used competing sentences to evaluate FM contributions to speech recognition in noise. Potential FM advantage was evaluated as a function of the number of spectral bands, FM depth, FM rate, and FM band distribution. Barring floor and ceiling effects, significant improvement was observed for all bands from 1 to 32 with the additional FM cue both in quiet and noise. Performance also improved with greater FM depth and rate, which might reflect resolved sidebands under the FM condition. Having FM present in low-frequency bands was more beneficial than in high-frequency bands, and only half of the bands required the presence of FM, regardless of position, to achieve performance similar to when all bands had the FM cue. These results provide insight into the relative contributions of AM and FM to speech communication and the potential advantage of incorporating FM for cochlear implant signal processing.

Acoustic Stimulation↗

Cochlear implant speech recognition with speech maskers.

Speech recognition performance was measured in normal-hearing and cochlear-implant listeners with maskers consisting of either steady-state speech-spectrum-shaped noise or a competing sentence. Target sentences from a male talker were presented in the presence of one of three competing talkers (same male, different male, or female) or speech-spectrum-shaped noise generated from this talker at several target-to-masker ratios. For the normal-hearing listeners, target-masker combinations were processed through a noise-excited vocoder designed to simulate a cochlear implant. With unprocessed stimuli, a normal-hearing control group maintained high levels of intelligibility down to target-to-masker ratios as low as 0 dB and showed a release from masking, producing better performance with single-talker maskers than with steady-state noise. In contrast, no masking release was observed in either implant or normal-hearing subjects listening through an implant simulation. The performance of the simulation and implant groups did not improve when the single-talker masker was a different talker compared to the same talker as the target speech, as was found in the normal-hearing control. These results are interpreted as evidence for a significant role of informational masking and modulation interference in cochlear implant speech recognition with fluctuating maskers. This informational masking may originate from increased target-masker similarity when spectral resolution is reduced.