PubMed Health⌕ Search

Biomedical subjects

Giorgio Bonmassar

Publications and source records attributed to Giorgio Bonmassar.

8 recordsLinked to original sources

EEG/(f)MRI measurements at 7 Tesla using a new EEG cap ("InkCap").

We aimed at improving the signal-to-noise ratio (SNR) of electroencephalography (EEG) during magnetic resonance imaging (MRI) by introducing a new EEG cap ("InkCap") based on conductive ink technology. The InkCap was tested with temperature measurements on an electrically conductive phantom head and during structural and functional MRI (fMRI) recordings in 11 healthy human volunteers at 7 T. Combined EEG/fMRI measurements were conducted to study the interaction between the two modalities. The EEG recordings with the InkCap demonstrated up to a five-fold average decrease in signal variance during echo-planar imaging, with respect to a cap made of standard carbon fiber leads. During concurrent EEG/fMRI measurements in human volunteers, alpha oscillations were clearly detected at 7 T. Minimal artifacts were present in the T2* and high-resolution structural MR images of the brain parenchyma. Our results show that the InkCap technology considerably improves the quality of both EEG and (f)MRI during concurrent measurements even at 7 T.

Adult↗

Task-modulated "what" and "where" pathways in human auditory cortex.

Human neuroimaging studies suggest that localization and identification of relevant auditory objects are accomplished via parallel parietal-to-lateral-prefrontal "where" and anterior-temporal-to-inferior-frontal "what" pathways, respectively. Using combined hemodynamic (functional MRI) and electromagnetic (magnetoencephalography) measurements, we investigated whether such dual pathways exist already in the human nonprimary auditory cortex, as suggested by animal models, and whether selective attention facilitates sound localization and identification by modulating these pathways in a feature-specific fashion. We found a double dissociation in response adaptation to sound pairs with phonetic vs. spatial sound changes, demonstrating that the human nonprimary auditory cortex indeed processes speech-sound identity and location in parallel anterior "what" (in anterolateral Heschl's gyrus, anterior superior temporal gyrus, and posterior planum polare) and posterior "where" (in planum temporale and posterior superior temporal gyrus) pathways as early as approximately 70-150 ms from stimulus onset. Our data further show that the "where" pathway is activated approximately 30 ms earlier than the "what" pathway, possibly enabling the brain to use top-down spatial information in auditory object perception. Notably, selectively attending to phonetic content modulated response adaptation in the "what" pathway, whereas attending to sound location produced analogous effects in the "where" pathway. This finding suggests that selective-attention effects are feature-specific in the human nonprimary auditory cortex and that they arise from enhanced tuning of receptive fields of task-relevant neuronal populations.

Adaptation, Physiological↗

Finger motion sensors for fMRI motor studies.

The kinematics of motor task performance affect brain activity. However, few functional magnetic resonance imaging (fMRI) motor studies have accounted for on-line kinematics because there are currently few MRI-compatible devices to record motor performance. We built a device based on Micro-Electro-Mechanical System (MEMS) gyroscopes that measures the angular velocity of one segment of each of the 10 fingers while a subject performs a finger motor task during fMRI. Finger position, acceleration, and jerk were computed from the angular velocity measurements. The signal-to-noise ratio (SNR) of the MEMS sensors (range: 27.10-34.36 dB) allowed for clear detection of velocity of finger motion during fMRI motor task performance, and showed good stability over time. We demonstrate that use of the MEMS-based device, while negligibly increasing radiofrequency (RF) noise in the scanning environment, did not cause MR image artifacts nor alter fMRI statistical activation maps. Further, we show that signal from the MEMS sensors was not affected by the high static magnetic field (3 T). Increasing the RF power transmitted during fMRI by using a body coil, as compared to a head coil, decreased the sensor's SNR from 30.7 to 24.2 dB, though this loss in SNR did not interfere with the ability to measure velocity of finger motion. We demonstrate the utility of the MEMS-based device in fMRI motor studies through two experiments that examined the relationship between finger movement kinematics and fMRI activation in the healthy and injured brain. On-line acquisition of motor performance during fMRI, through the use of the MEMS-based device, promises to allow for a more detailed understanding of the relationship between movement kinematics and activation in the healthy and injured brain.

Adult↗

On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies.

The purpose of the study was to assess the effects of electrodes and leads on electromagnetic field and specific absorption rate (SAR) distributions during simultaneous electroencephalography (EEG) and 7-T MRI. Two different approaches were evaluated and compared to the case without electrodes: (a) the use of different EEG lead resistivity and (b) the use of a radiofrequency (RF) resistor on the lead near the EEG electrode. These configurations are commonly used in research and clinical settings. Electromagnetic field and SAR distributions generated by the transmit RF coil were evaluated using finite difference time domain simulations on an anatomically accurate head model. The spatiotemporal changes of temperature were estimated with the heat equation. Temperature changes during turbo spin echo sequences were also measured using a custom-made phantom: the conductive head mannequin anthropomorphic (CHEMA). The results of this study showed that the SAR and temperature distributions in CHEMA (a) increased when using low resistive leads, with respect to the no-electrode case; (b) were affected by the resistivity of the EEG leads, with carbon fiber leads performing better than standard copper leads; and (c) were not affected by the use of an RF resistor between the EEG electrode and the lead.

Electrodes↗

Human posterior auditory cortex gates novel sounds to consciousness.

Life or death in hostile environments depends crucially on one's ability to detect and gate novel sounds to awareness, such as that of a twig cracking under the paw of a stalking predator in a noisy jungle. Two distinct auditory cortex processes have been thought to underlie this phenomenon: (i) attenuation of the so-called N1 response with repeated stimulation and (ii) elicitation of a mismatch negativity response (MMN) by changes in repetitive aspects of auditory stimulation. This division has been based on previous studies suggesting that, unlike for the N1, repetitive "standard" stimuli preceding a physically different "novel" stimulus constitute a prerequisite to MMN elicitation, and that the source loci of MMN and N1 are different. Contradicting these findings, our combined electromagnetic, hemodynamic, and psychophysical data indicate that the MMN is generated as a result of differential adaptation of anterior and posterior auditory cortex N1 sources by preceding auditory stimulation. Early ( approximately 85 ms) neural activity within posterior auditory cortex is adapted as sound novelty decreases. This alters the center of gravity of electromagnetic N1 source activity, creating an illusory difference between N1 and MMN source loci when estimated by using equivalent current dipole fits. Further, our electroencephalography data show a robust MMN after a single standard event when the interval between two consecutive novel sounds is kept invariant. Our converging findings suggest that transient adaptation of feature-specific neurons within human posterior auditory cortex filters superfluous sounds from entering one's awareness.

Adult↗

Basal ganglia activity remains elevated after movement in focal hand dystonia.

Although previous studies of focal hand dystonia have detected cortical sensorimotor abnormalities, little is known about the role of the basal ganglia in this disorder. We report here that when focal hand dystonic patients performed finger-tapping tasks, functional magnetic resonance imaging showed persisting elevations of basal ganglia activity after the tasks ended. We posit that inhibitory control of the basal ganglia may be faulty in focal hand dystonia, and that the increases we observe in "resting" activity may mask basal ganglia abnormalities in standard imaging contrast analyses.

Adult↗

Metallic electrodes and leads in simultaneous EEG-MRI: specific absorption rate (SAR) simulation studies.

The purpose of this study was to investigate the changes in specific absorption rate (SAR) in human-head tissues while using nonmagnetic metallic electroencephalography (EEG) electrodes and leads during magnetic resonance imaging (MRI). A realistic, high resolution (1 mm(3)) head model from individual MRI data was adopted to describe accurately thin tissues, such as bone marrow and skin. The RF power dissipated in the human head was evaluated using the FDTD algorithm. Both surface and bird cage coils were used. The following numbers of EEG electrodes/leads were considered: 16, 31, 62, and 124. Simulations were performed at 128 and 300 MHz. The difference in SAR between the electrodes/leads and no-electrodes conditions was greater with the bird cage coil than with the surface coil. The peak 1 g averaged SAR values were highest at 124 electrodes, increasing to as much as two orders of magnitude (x172.3) at 300 MHz compared to the original value. At 300 MHz, there was a fourfold (x3.6) increase of SAR averaged over the bone marrow, and a sevenfold (x7.4) increase in the skin. At 128 MHz, there was a fivefold (x5.6) increase of whole head SAR. Head models were obtained from two different subjects, with an inter-subject whole head SAR variability of 3%. .

Adult↗

Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI.

Artifacts generated by motion (e.g., ballistocardiac) of the head inside a high magnetic field corrupt recordings of EEG and EPs. This paper introduces a method for motion artifact cancellation. This method is based on adaptive filtering and takes advantage of piezoelectric motion sensor information to estimate the motion artifact noise. This filter estimates the mapping between motion sensor and EEG space, subtracting the motion-related noise from the raw EEG signal. Due to possible subject motion and changes in electrode impedance, a time-varying mapping of the motion versus EEG is required. We show that this filter is capable of removing both ballistocardiogram and gross motion artifacts, restoring EEG alpha waves (8-13 Hz), and visual evoked potentials (VEPs). This adaptive filter outperforms the simple band-pass filter for alpha detection because it is also capable of reducing noise within the frequency band of interest. In addition, this filter also removes the transient responses normally visible in the EEG window after echo planar image acquisition, observed during interleaved EEG/fMRI recordings. Our adaptive filter approach can be implemented in real-time to allow for continuous monitoring of EEG and fMRI during clinical and cognitive studies.

Adult↗