PubMed Health⌕ Search

Biomedical subjects

Giorgio Tomasi

Publications and source records attributed to Giorgio Tomasi.

4 recordsLinked to original sources

Dioxin screening in fish product by pattern recognition of biomarkers.

Two alternative, cost- and time-effective dioxin screening methods relying on two categories of potential lipid biomarkers were investigated. A dioxin range varying from 1.1 to 47.1 pg PCDD/F TEQ-WHO/g lipid using 64 fish meal samples was used for model calibration. The methods were based on multivariate models using either (1) fatty acid composition monitored by GC-FID or (2) fluorescence landscape signals analysed using the PARAFAC model and in both cases predicting dioxin content as pgPCDD/F TEQ-WHO/g lipid. In both cases, Partial Least Squares (PLS) regression was performed for predicting the dioxin content of a sample. The GC-FID data analyses was based on automatic peak alignment and integration, enabling extraction of the area of 140 peaks from the gas chromatograms, as opposed to the 31 fatty acids usually considered for fish oil characterisation. In addition to classic PLS employing the whole dataset for calibration, a two-step local PLS modeling approach was performed based upon an initial selection of k number of calibration samples providing the best match to the prediction sample using a so-called k Nearest Neighbors (kNN) approach, then followed by PLS calibration on these kNN selected samples for dioxin prediction. Fluorescence spectroscopy offers a promising non-invasive and ultra-rapid technique, with less than two minutes analysis time. However, fluorescence spectroscopy using the pattern recognition "kNN-PLS" yielded a correlation of 0.76 (r2) and a high root mean square error of prediction of 11.4 pg PCDD/F TEQ-WHO/g lipid. The predictions were improved when the PLS calibration was performed on all the sample with a root mean square error of prediction of 7.0 pg PCDD/F TEQ-WHO/g lipid. Unfortunately, these results failed to demonstrate the potential of fluorophore monitoring as a screening method. In contrast, the overall best screening performance was obtained with the fatty acid profile, when the kNN-PLS combination employed for pattern recognition (kNN) all the areas of the 140 detected peaks and the PLS regression used the areas of 46 selected peaks. This "kNN-PLS" prediction with three latent variables and based upon the 12 nearest neighbors selected out of the 64 x 2 fatty acid profiles (duplicate analyses), yielded a correlation of 0.85 (r2) and a root mean square error of prediction of 2.1 pg PCDD/F TEQ-WHO/g lipid and resulted in a total analysis time of one and half hour per sample.

Animals↗

Chemical fingerprinting of petroleum biomarkers using time warping and PCA.

A new method for chemical fingerprinting of petroleum biomakers is described. The method consists of GC-MS analysis, preprocessing of GC-MS chromatograms, and principal component analysis (PCA) of selected regions. The preprocessing consists of baseline removal by derivatization, normalization, and alignment using correlation optimized warping. The method was applied to chromatograms of m/z 217 (tricyclic and tetracyclic steranes) of oil spill samples and source oils. Oil spill samples collected from the coastal environment in the weeks after the Baltic Carrier oil spill were clustered in principal components 1 to 4 with oil samples from the tank of the Baltic Carrier (source oil). The discriminative power of PCA was enhanced by deselecting the most uncertain variables or scaling them according to their uncertainty, using a weighted least squares criterion. The four principal components were interpreted as follows: boiling point range (PC1), clay content (PC2), carbon number distribution of sterols in the source rock (PC3), and thermal maturity of the oil (PC4). In summary, the method allows for analyses of chromatograms using a fast and objective procedure and with more comprehensive data usage compared to other fingerprinting methods.

Accidents↗

Integrated methodology for forensic oil spill identification.

A new integrated methodology for forensic oil spill identification is presented. It consists of GC-MS analysis, chromatographic data processing, variable-outlier detection, multivariate data analysis, estimation of uncertainties, and statistical evaluation. The methodology was tested on four groups of diagnostic ratios composed of petroleum biomarkers and ratios within homologous PAH categories. Principal component analysis (PCA) was employed and enabled the simultaneous analysis of many diagnostic ratios. Weathering was taken into account by considering the sampling uncertainties estimated from replicate spill samples. Statistical evaluation ensured an objective matching of oil spill samples with suspected source oils as well as classification into positive match, probable match, and nonmatch. The data analysis is further refined if two or more source oils are classified as probable match by using weighted least squares fitting of the principal components, local PCA models, and additional information relevant to the spill case. The methodology correctly identified the source of two spill samples (i.e., crude oils from Oseberg East and Oseberg Field Centre) and distinguished them from closely related source oils.

Denmark↗

Application of multi-way models to the time-resolved fluorescence of polycyclic aromatic hydrocarbons mixtures in water.

The time-resolved laser-induced fluorescence of a series of polycyclic aromatic compounds (PAHs) and mixtures of these latter in aqueous solution was measured by means of an apparatus equipped with optical fibers, which allows their real time in situ monitoring. The potential of such spectroscopic technique, yielding 4-way fluorescence data arrays, together with the application of multi-way models to the matricized data, was tested for the resolution of complex aqueous mixtures containing low concentrations of PAHs, as typical fluorescent pollutants in aquatic systems. PARAllel FACtors analysis was employed for the qualitative resolution of PAHs mixtures and for calculating the fluorescence lifetimes of single PAHs; n-way partial least squares analysis was applied for evaluating the concentration of the single PAHs in the aqueous mixtures.

Environmental Monitoring↗