PubMed Health⌕ Search

Biomedical subjects

Giovanni Dugo

Publications and source records attributed to Giovanni Dugo.

At least 19 recordsLinked to original sources

Odour fingerprint acquisition by means of comprehensive two-dimensional gas chromatography-olfactometry and comprehensive two-dimensional gas chromatography/mass spectrometry.

The analysis of complex matrices, such as perfumes, by means of gas chromatography-olfactometry (GC-O) can be rather imprecise due to the co-elutions, leading to a possible masking of odour-active trace-level compounds by major interferences or agglomeration of olfactive impressions resulting in unreliable olfactive characterization. To overcome these limits an innovative technique, comprehensive two-dimensional gas chromatography-olfactometry (GC x GC-O), was applied, revealing several relevant co-elutions, as in the linalool and linalyl acetate zones. A total of 177 compounds, out of these 135 odour-active, were detected by GC-O, while about 481 out of 818 compounds presented odour-activity through GC x GC-O analyses. In addition, GC/mass spectrometry (GC/MS) and GC x GC/MS analyses were also performed. Peak assignment was achieved by means of different information sources, such as GC/MS, GC x GC/MS, LRI, injection of standards and olfactive impressions.

Chromatography, Gas↗

Rapid, micro-scale preparation and very fast gas chromatographic separation of cod liver oil fatty acid methyl esters.

The present research is focussed on the optimization of a fast and economically convenient method for the sample preparation and gas chromatographic separation of fatty acids contained in lipidic samples. This, as part of a wider project that has, as ultimate goal, the automation of this specific analytical procedure. The developed approach was applied to the analysis of cod liver oil, a highly complex lipid characterized by a wide nutritional interest. Derivatization was carried out by using low quantities (microL amounts) of a reagent and solvent, while the derived fatty acid methyl esters (FAMEs) were separated in 120 s on a 10 m x 0.1 mm i.d. polar micro-bore column. The total analysis time required for six samples was approximately 45 min (7.5 min/sample), considering a simultaneous process of methylation and GC separation of previously prepared samples. The results obtained were compared to those derived from conventional applications on the same sample. With regard to the validation of the rapid method, peak area/retention time repeatability, linear range, limit of detection (LOD) and quantitation (LOQ) were determined. Peak assignment was carried out by exploiting bidimensional group-type mapping information obtained in a comprehensive gas chromatographic application.

Animals↗

Evaluation of leaf-derived extracts as an environmentally sustainable source of essential oils by using gas chromatography-mass spectrometry and enantioselective gas chromatography-olfactometry.

In consideration of the world's present environmental situation and the threat of species extinction, investigations concerning alternative sustainable sources of natural substances represent an extremely important issue. In this respect, the present research is focused on the analytical evaluation of Brazilian rosewood (Aniba rosaeodora Ducke) leaves, as an alternative source (with respect to wood) of rosewood essential oil and, as such, of natural linalool, which is extensively used in perfumery. Enantioselective-gas chromatography-olfactometry (Es-GC-O) was used as a tool for the simultaneous stereodifferentiation and olfactive evaluation of the volatile optically active components present in the analyzed samples. In addition to Es-GC-O analyses, direct olfactive analyses were also performed, enabling the evaluation of the global aroma exerted by each sample and the influence of each linalool antipode, as also other minor compounds. The samples were also submitted to gas chromatography-mass spectrometric analysis, thus establishing their chemical profiles. The assessment of enantiopure chiral compounds through Es-GC-O, along with direct olfactive analyses, confirmed that the leaves are a potential substituent for wood in the extraction of Brazilian rosewood essential oil, representing a sustainable nonwood source of natural linalool.

Chromatography, Gas↗

Determination of beef tallow in lard through a multidimensional off-line non-aqueous reversed phase-argentation LC method coupled to mass spectrometry.

The presence of tallow in lard is not easy to determine, due to the similarity of the composition of these two animal fats, which differ mainly in the distribution of fatty acids (FA) in the three positions of the glycerol molecule. The determination of the composition of the triacylglycerol (TAG) fraction of lard, tallow, and their mixtures was investigated by HPLC in combination with atmospheric pressure chemical ionization mass spectrometry (APCI-MS). The presence of tallow in lard was determined through the study of the sn-POP/sn-PPO ratio by multidimensional HPLC. The off-line bidimensional system was attained through the coupling of non-aqueous reversed phase (NARP)-HPLC and silver ion (Ag)-HPLC. The primary column eluate was fractionated and the fraction containing POP/PPO isomers was injected onto the secondary column, allowing the separation of positional isomers, unresolved in the first dimension. Peak assignment was carried out by combining retention data with APCI-MS spectral information. The fatty acid distribution along the glycerol backbone, determined by Ag-HPLC, was confirmed through diglyceride ion ratios derived from APCI-MS analysis. Method validation was carried out in preliminary applications on standard TAGs. The analytical results obtained show that even a 5% addition of tallow to lard modifies the distribution of positional isomers.

Animals↗

Optimization of a comprehensive two-dimensional normal-phase and reversed-phase liquid chromatography system.

The present investigation is based on the evaluation of the performance of a comprehensive two-dimensional liquid chromatography (LCxLC) system during method optimization. The LCxLC set-up, operated in normal phase (NP) mode (adsorption) in the first dimension (1D) and reversed-phase (RP) mode in the second dimension (2D), is equipped with a 1D microbore silica column and a 2D monolithic C(18) column with a 10-port two position valve as the interface. A photodiode array detector is used after the 2D separation. A possible cause of peak distorsion because of the immiscibility of the mobile phases employed in the two dimensions is resolved. The optimization of the analytical run time and flow rate for both dimensions and the initial gradient in the 2D is carried out with various standard compounds. The potential and versatility of this LCxLC approach is demonstrated through the separation of 11 standard components, most of them allergens. The latter, which are characterized by a scattered distribution on the 2D space plane, underwent separation on both a hydrophobicity and polarity basis.

Chromatography, Liquid↗

High-throughput analysis of bergamot essential oil by fast solid-phase microextraction-capillary gas chromatography-flame ionization detection.

The advantages of using a narrow-bore column in headspace solid-phase microextraction-gas chromatographic (HS-SPME-GC) analysis are investigated. An automated rapid HS-SPME-GC method for the determination of volatile compounds in a complex sample (bergamot essential oil) was developed. A low-capacity (7 microm) SPME fibre was employed, enabling a short equilibration time (15 min). The absorbed volatile compounds were then separated in 12.5 min on a 10 m x 0.1 mm I.D. capillary. The fast GC method was characterized by relatively moderate GC parameters (head pressure: 173 kPa; temperature program rate: 12 degrees C/min). The employment of the low-capacity fibre also suited the reduced sample capacity of the capillary employed, hence column overloading was avoided. Analytical repeatibility was determined in terms of retention times (maximum RSD: 0.32%) and peak areas (maximum RSD: 9.80%). The results obtained were compared to those derived from a conventional HS-SPME-GC (a 30 microm SPME fibre and 0.25 mm I.D. capillary were used) application on the same sample. In this respect, a great reduction of analytical time was obtained both with regard to the conventional SPME equilibration and GC run times, which both required 50 min. Peak resolution was altogether comparable in both applications. Although a slight loss in terms of sensitivity was observed in the rapid approach (generally within the 25-50% range), this did not impair the detection of all peaks of interest. Finally, the selectivities of the 30 and 7 microm fibres were evaluated and, as expected, these were in good agreement.

Chemical Fractionation↗

Fast enantiomeric analysis of a complex essential oil with an innovative multidimensional gas chromatographic system.

The present research is focussed on the evaluation of a recently developed high performance multidimensional gas chromatographic (MDGC) system employed in the fast analysis of a series of chiral compounds contained in rosemary essential oil. The heart of the MDGC system consists in a simple transfer device for the rapid sequential re-injection of analyte "heart-cuts" from the first to the second dimension. The transfer system has no temperature restrictions, presents very low dead volumes and achieves multidimensional analysis through a pressure-balance mechanism. The MDGC set-up is characterized by two GC ovens (enabling independent temperature programming) and the possibility of mass spectrometric (MS) and/or flame ionization detection (FID). Multiple-cut conventional and fast MDGC-FID methods were developed and the results obtained compared, in order to evaluate the effectiveness of the system. In this respect, the rapid method provided the same analytical result in a greatly reduced time (approximately five times less). Furthermore, quali/quantitative data reproducibilty was very good. Fast MDGC was achieved by using micro-bore (0.1mm I.D.) columns in both dimensions.

Chromatography, Gas↗

Comprehensive two-dimensional gas chromatography in combination with rapid scanning quadrupole mass spectrometry in perfume analysis.

Single column gas chromatography (GC) in combination with a flame ionization detector (FID) and/or a mass spectrometer is routinely employed in the determination of perfume profiles. The latter are to be considered medium to highly complex matrices and, as such, can only be partially separated even on long capillaries. Inevitably, several monodimensional peaks are the result of two or more overlapping components, often hindering reliable identification and quantitation. The present investigation is based on the use of a comprehensive GC (GC x GC) method, in vacuum outlet conditions, for the near to complete resolution of a complex perfume sample. A rapid scanning quadrupole mass spectrometry (qMS) system, employed for the assignment of GC x GC peaks, supplied high quality mass spectra. The validity of the three-dimensional (3D) GC x GC-qMS application was measured and compared to that of GC-qMS analysis on the same matrix. Peak identification, in all applications, was achieved through MS spectra library matching and the interactive use of linear retention indices (LRI).

Gas Chromatography-Mass Spectrometry↗

A comparison between different techniques for the isolation of rosemary essential oil.

Traditional hydrodistillation (HD), supercritical fluid extraction (SFE), organic solvent extraction (SE), and water microwave assisted hydrodistillation (MAHD) techniques were compared and evaluated for their effectiveness in the isolation of rosemary essential oil. The microwave assisted hydrodistillation technique was optimized in terms of both delivered power and time duration. The extracts/distillates were analyzed by GC and GC-MS. Microwave distillation, which exploits the physical action of microwaves on plants, showed a series of advantages over the other approaches: low cost, use of water in sample pre-treatment step, greatly reduced isolation time, and attainment of high quality essential oil distillate. Moreover, the absence of environmental impact of this innovative technique was also emphasized.

Gas Chromatography-Mass Spectrometry↗

Reliable characterization of coffee bean aroma profiles by automated headspace solid phase microextraction-gas chromatography-mass spectrometry with the support of a dual-filter mass spectra library.

This investigation is based on the automated solid phase microextraction GC-MS analysis of the volatile fraction of a variety of coffee bean matrices. Volatile analytes were extracted by headspace (HS)-SPME which was achieved with the support of automated instrumentation. The research was directed towards various important aspects relating to coffee aroma analysis: monitoring of the volatile fraction formation during roasting; chromatographic differentiation of the two main coffee species (Arabica and Robusta) and of a single species from different geographical origins; evaluation of the influence of specific industrial treatments prior to roasting. Reliable peak assignment was carried out through the use of a recently laboratory-constructed "flavour and fragrance" library and a dual-filter MS spectral search procedure. Further emphasis was placed on the automated SPME instrumentation and on its ability to supply highly repeatable chromatographic data.

Coffee↗

Determination of flavonoids in citrus juices by micro-HPLC-ESI/MS.

Flavonoids are a large class of naturally occurring aromatic secondary plant metabolites. They constitute one of the most characteristic classes found in nature and more than 4000 flavonoids have been identified and divided into several subclasses. Flavonoids have several effects on human health, mainly related to their antioxidant activity. As a result of the increased interest in the biologically active compounds in food, many research studies have investigated the detection and quantification of antioxidants. Citrus plants are of great interest since they accumulate large amounts of flavonoids and fruit and juices of these species are consumed in large quantities. Despite the extensive research performed on Citrus flavonoids, many compounds still remain unidentified. In this work, flavonoids of five citrus juices: lemon, grapefruit, bergamot, orange, and mandarin were analyzed by microHPLC coupled on-line with an MS detector equipped with an ESI source operating in negative mode. The use of microcolumn HPLC greatly enhanced detection performance. In total, 20 flavonoids of two different subclasses (flavanone and flavone glycosides) were identified with the help of retention data and MS spectral information.

Beverages↗

Comprehensive two-dimensional chromatography in food analysis.

Comprehensive two-dimensional (2D) chromatographic techniques can be considered innovative methods, only quite recently developed. Since their introduction to the chromatographic community, these techniques have been used in several fields and have gained an excellent reputation as valuable and powerful analytical tools. The revolutionary aspect of comprehensive multidimensional (MD) techniques, in respect to classical MD chromatography, is that the entire sample is subjected to the 2D advantage. The resulting unprecedented separating capacity makes these approaches prime choices when analysts are challenged with highly complex mixtures. Furthermore, in the case of automated systems, instrumental analysis times are roughly the same as in monodimensional applications. The present review reports various comprehensive chromatographic applications on different food matrices. The GC x GC section highlights two fundamental aspects for component separation/identification: the exceptional peak capacity and the formation of group types on the 2D space plane. The LC x LC section reports the employment in food analysis of a recently developed multidimensional normal-phase (NP)-reversed-phase (RP) high performance liquid chromatography (HPLC) system. Also reported are comprehensive LC x GC and packed column supercritical fluid chromatography (pSFC x pSFC) applications in this field.

Chromatography, Gas↗

Off-line coupling of non-aqueous reversed-phase and silver ion high-performance liquid chromatography-mass spectrometry for the characterization of rice oil triacylglycerol positional isomers.

The determination of the triacylglycerol (TAG) profile in real world matrices is rather difficult as these compounds present a complex composition and are characterized by similar physico-chemical properties. This investigation is based on the high-performance liquid chromatography (HPLC) multidimensional determination of the TAG profile in terms of TAG species and positional isomers in a rice oil sample. The off-line bi-dimensional system was attained through the coupling of non-aqueous reversed-phase HPLC and silver ion (Ag)-HPLC. The primary column eluate was fractionated and the fractions of interest were then injected onto the secondary column, allowing the separation of several TAG positional isomers, unresolved in the first dimension. Peak assignment was carried out by combining retention data with atmospheric pressure chemical ionisation (APCI) MS spectra information. The fatty acid distribution along the glycerol backbone, determined by Ag-HPLC, was confirmed through diglyceride ion ratios derived from APCI-MS analysis. Method validation, where both precision and accuracy were measured, was carried out in preliminary applications on standard compounds. The analytical results obtained show that rice oil TAGs follow a distribution which can be considered typical for vegetable oils.

Atmospheric Pressure↗

Evaluation of fast gas chromatography and gas chromatography-mass spectrometry in the analysis of lipids.

Fast and conventional gas chromatography (GC) techniques were applied to nine different lipidic matrices (butter, lard, tallow, and peanut, corn, sunflower, soya, olive, menhaden oils). Simultaneous methylic transesterification was performed on all samples prior to GC analysis. Several practical aspects concerning high speed analysis were investigated, such as the great increase in linear velocity, the use of fast temperature ramps, column sample capacity and detection systems. Analytical results showed certain losses in resolution, balanced by a consistent reduction in analysis time. The actual time savings were variable (60-70 min) as they were dependent on the complexity of the sample while the speed enhancement factor was equal to 10.5. Peak identification was achieved by means of different information sources, such as fast GC-mass spectrometry (MS), linear retention indices and comprehensive two-dimensional (2D) gas chromatography group patterns. The method developed was shown to be applicable in routine applications on complex natural samples.

Chromatography, Gas↗

Comprehensive two-dimensional normal-phase (adsorption)-reversed-phase liquid chromatography.

A comprehensive two-dimensional HPLC system has been developed. It is based on the use of a microbore silica column operated in normal-phase (adsorption) mode (NP) in the first dimension and a monolithic type C18 column operated in reversed-phase (RP) mode in the second dimension. The interface was a 10-port, 2-position valve equipped with two storage loops. The first column was operated at a flow rate of 20 microL/min in isocratic mode, while the monolithic column flow rate was 4 mL/min and was operated in gradient mode. The sample loops had a volume of 20 microL each, and the analysis time in the second dimension was 1 min. In this way, every fraction from the first dimension was transferred on-line to the second dimension switching the automated valve every minute. A photodiode array detector has been used after the secondary column. The use of normal- and reversed-phase mode in the two dimensions can be helpful in the separation of complex mixtures of a natural origin that contain uncharged molecules of comparable dimension, different in polarity and hydrophobicity. The use of a microbore column in the first dimension permits the injection of a small volume in the secondary column, making the transfer of incompatible solvents from the first to the second dimension possible. Since the mobile phase in the NP separation is always stronger than the mobile phase at the head of the secondary column operated in RP mode, the initial eluent strength is important in order to obtain an effective focusing of the sample. The use of a monolithic type column in the second dimension permits the performance of very fast analysis operating at higher flow rates without loss of resolution, due to a higher permeability and increased mass-transfer properties in comparison to conventional particulate columns. Due to the brief reconditioning time necessary for monolithic columns, repetitive gradients can be carried out, extending the field of application to mixtures that contain components with different polarities. The utility of the system has been demonstrated in the analysis of the oxygen heterocyclic fraction of cold-pressed lemon oil, made up of coumarins and psoralens. These components may contain hydroxyl, methoxyl, isopentenyl, isopentenyloxyl, and geranyloxyl groups and oxygen-containing modification of the terpenoid side-chain groups, such as epoxides or vicinal diol groups. The relative location of the components in the 2D plane varied in relation to their chemical structure and allowed positive peak identification. The UV spectra recorded with the photodiode array detector supplied additional information that was used for the characterization of the studied sample.

Adsorption↗

Ultra-fast essential oil characterization by capillary GC on a 50 microm ID column.

A 5 m x 50 microm capillary column with 0.05 microm stationary phase film thickness, with a calculated efficiency of almost 20,000 plates per metre (under optimum conditions), was used for very fasthigh resolution GC analysis of lime essential oil. The total analysis time of this volatile essential oil was less than 90 s. Fast GC is shown to be appropriate for essential oil quality assurance analysis, and quantitative results of key components are comparable with those obtained by using conventional GC analysis. The fast GC analysis is approximately 33 times faster than the conventional GC method.

Chromatography, Gas↗

Comprehensive multidimensional GC for the characterization of roasted coffee beans.

The present investigation is based on the separation of one of the most complex food matrices: the roasted coffee bean volatile fraction. Analysis of the two main species of coffee (Arabica/Robusta) was achieved through an effective and simple sampling procedure, headspace solid-phase microextraction (SPME), and the unprecedented resolving power of comprehensive gas chromatography (GC x GC). The combination of these two techniques proved to be a powerful tool for the extraction and separation of coffee volatiles. In fact, thousands of compounds that play various roles in the constitution of coffee aroma profile were resolved in the 2-D contour plot, each occupying a specific position pinpointed by two retention time coordinates. The potential use of this method for the assessment of coffee quality and the detection of commercial fraud is discussed. The potential of GC x GC for identification and classification of unknowns was also demonstrated, as the formation of characteristic patterns for structurally related compounds was observed in the bidimensional chromatogram. Moreover, reproducibility results were supported by the use of an autosampler for SPME applications that allowed any inaccuracy arising from manual handling to be avoided.

Journal Article↗

Determination of anthocyanins and related components in red wines by micro- and capillary HPLC.

Anthocyanins and derived components of red wines were determined by microHPLC using a 1 mm ID HPLC column coupled on-line with an MS detector equipped with an ESI (ElectroSpray Ionisation) source. The use of microcolumn HPLC greatly enhanced detection performance, allowing direct identification of components present in the fraction. Nineteen anthocyanins were detected. Fifteen were identified, two were tentatively identified, and only the aglycon of the remaining two components was certainly identified. Six anthocyanin-derived pigments, supposedly formed during wine maturation, were also investigated and found in a wine sample. The analysis of red wine anthocyanins was also carried out by injecting a large sample volume onto a 0.32 mm ID HPLC column, using the column focusing technique, in order to decrease the limit of detection and quantification of components present in a very small amounts.