PubMed Health⌕ Search

Biomedical subjects

Giuseppe M Peretti

Publications and source records attributed to Giuseppe M Peretti.

13 recordsLinked to original sources

An allogenic cell-based implant for meniscal lesions.

BACKGROUND: Meniscal tears in the avascular zones do not heal. Although tissue-engineering approaches using cells seeded onto scaffolds could expand the indication for meniscal repair, harvesting autologous cells could cause additional trauma to the patient. Allogenic cells, however, could provide an unlimited amount of cells. HYPOTHESIS: Allogenic cells from 2 anatomical sources can repair lesions in the avascular region of the meniscus. STUDY DESIGN: Controlled laboratory study. METHODS: Both autologous and allogenic chondrocytes were seeded onto a Vicryl mesh scaffold and sutured into a bucket-handle lesion created in the medial menisci of 17 swine. Controls consisted of 3 swine knees treated with unseeded implants and controls from a previous experiment in which 4 swine were treated with suture only and 4 with no treatment. Menisci were harvested after 12 weeks and evaluated histologically for new tissue and percentage of interface healing surface; they were also evaluated statistically. RESULTS: The lesions were closed in 15 of 17 menisci. None of the control samples demonstrated healing. Histologic analysis of sequential cuts through the lesion showed formation of new scar-like tissue in all experimental samples. One of 8 menisci was completely healed in the allogenic group and 2 of 9 in the autologous group; the remaining samples were partially healed in both groups. No statistically significant differences in the percentage of healing were observed between the autologous and allogenic cell-based implants. CONCLUSION: Use of autologous and allogenic chondrocytes delivered via a biodegradable mesh enhanced healing of avascular meniscal lesions. CLINICAL RELEVANCE: This study demonstrates the potential of a tissue-engineered cellular repair of the meniscus using autologous and allogenic chondrocytes.

Absorbable Implants↗

Healing potential of transplanted allogeneic chondrocytes of three different sources in lesions of the avascular zone of the meniscus: a pilot study.

UNLABELLED: Successful treatment of tears to the avascular region of the meniscus remains a challenge. Current repair techniques, such as sutures and anchors, are effective in stabilizing the peripheral, vascularized regions of the meniscus, but are not adequate for promoting healing in the avascular region. The purpose of this study was to demonstrate the healing ability of a tissue-engineered repair technique using allogenic chondrocytes from three different sources for the avascular zone of the meniscus. MATERIAL AND METHODS: Articular, auricular, and costal chondrocytes were harvested from 3-month-old Yorkshire swine. A 1-cm bucket-handle lesion was created in the avascular zone of each three swine. A cell-scaffold construct, composed of a single chondrocyte cell type and Vicryl mesh, was implanted into the lesion and secured with two vertical mattress sutures. Controls consisted of each three sutured unseeded mesh implants, suture only, and untreated lesions. The swine were allowed immediate post-operative full weight bearing. Menisci and controls were harvested after 12 weeks. RESULTS: In all experimental samples, lesion closure was observed. Gross mechanical testing with two Adson forceps demonstrated bonding of the lesion. Histological analysis showed formation of new tissue in all three experimental samples. None of the control samples demonstrated closure and formation of new matrix. CONCLUSION: We present preliminary data that demonstrates the potential of a tissue-engineered, allogenic cellular repair to provide successful healing of lesions in the avascular zone in a large animal model.

Animals↗

Tissue engineered cartilage integration to live and devitalized cartilage: a study by reflectance mode confocal microscopy and standard histology.

This study investigated the in vivo formation of engineering cartilage within living or devitalized cartilage discs using reflectance mode confocal microscopy and conventional light microscopy. Pig articular chondrocytes were suspended in fibrin glue and placed between two cartilage discs. Four experimental groups were prepared: in groups 1 and 2, the cell-hydrogel composite was placed between two live or between two devitalized cartilage discs, respectively; in groups 3 and 4, acellular fibrin glue was placed between two live or between two devitalized cartilage discs, respectively. Samples were implanted in the back of nude mice and analyzed after 2, 5, and 8 weeks. Results showed that engineered cartilage seems to grow more homogenously when the cell-seeded gel was placed between devitalized cartilages than when it was placed between live cartilage matrices. Confocal microscopy provides valuable information on the integration of tissue-engineered cartilage with native tissue and could be useful for nondestructive imaging in vivo.

Animals↗

Review of injectable cartilage engineering using fibrin gel in mice and swine models.

More than a decade of work has been devoted to engineering cartilage for articular surface repair. This review covers the use of fibrin gel polymer as an injectable scaffold for generating new cartilage matrix from isolated articular chondrocytes beginning with studies in mice and culminating in an applied study in swine joints. These studies began with developing a formulation of fibrin that was injectable and promoted cartilage matrix formation. Subsequent studies addressed the problems of volume loss after the scaffolds were placed in vivo by adding lyophilized cartilage matrix. Additional studies focused on the ability of isolated chondrocytes to heal and repair cartilage in a model that could be biomechanically tested. In conclusion, this series of studies demonstrated that fibrin gel is a suitable polymer gel for generating new cartilage matrix from articular chondrocytes. The new matrix is capable of forming mechanical bonds between cartilage disks and can lead to healing and integration. Armed with these results, implantation of fibrin-cell constructs into defects in swine knees showed new cartilage formation and filling of the defects. Continuing work in these models with fibrin and other polymerizable hydrogels could result in a suitable cell-based therapy for articular cartilage lesions.

Animals↗

Tissue-engineered flexible ear-shaped cartilage.

BACKGROUND: Previous attempts to engineer human ear-shaped constructs mimicked human shape but lacked the flexibility and size of a human ear. Recently, the authors engineered flexible cartilage by incorporating a perichondrium-like layer into the construct. In this study, they used lyophilized swine perichondrium as a pseudoperichondrium, examined its ability to confer flexibility to tissue-engineered cartilage, and used it to engineer flexible cartilage in the shape and size of a human ear. METHODS: Auricular chondrocytes and perichondrium were isolated from swine. Chondrocytes were mixed with fibrin polymer and gelled to form 5 x 20-mm constructs. Constructs alone (control, n = 6) or constructs sandwiched between two layers of lyophilized swine perichondrium (experimental, n = 6) were implanted into athymic mice. Auricular chondrocytes in fibrin polymer and lyophilized perichondrium were also used to form a tri-layer, ear-shaped construct, which was implanted into an athymic rat and externally stented for 6 weeks (n = 1). At 12 weeks, constructs were analyzed with histology and gross mechanical testing. RESULTS: New cartilaginous tissue was engineered in both the experimental and control groups. In samples laminated with lyophilized swine perichondrium, the intimate integration of the laminate with the neocartilage closely resembled the histoarchitecture of the native swine ear. Experimental constructs had mechanical properties similar to those of the native swine ear, while control constructs fractured with similar testing. The engineered ear could not be fractured with gross mechanical testing, and its size, shape, and flexibility remained stable. CONCLUSIONS: This study demonstrates that it is possible to engineer a cartilage construct that resembles the human ear not only in shape but also in size and flexibility. This study also confirms that lamination is a reliable method to confer elastic-like flexibility to an engineered cartilage construct.

Animals↗

Producing a flexible tissue-engineered cartilage framework using expanded polytetrafluoroethylene membrane as a pseudoperichondrium.

BACKGROUND: Both native and engineered cartilage is brittle and fractures easily without perichondrium. The aim of this study was to understand the role of the perichondrium and try to enhance the flexible properties of tissue-engineered cartilage using expanded polytetrafluoroethylene (ePTFE) membrane as a pseudoperichondrium. METHODS: The study was conducted in two phases. In phase I, native swine auricular cartilage of different thicknesses was studied by histologic evaluation and failure testing. Next, isolated perichondrium was bonded to native cartilage slices using fibrin glue or Dermabond and tested to failure. In phase II, swine auricular chondrocytes were suspended in fibrin glue. The chondrocyte-fibrin glue composites were then bound to expanded polytetrafluoroethylene membrane in two trilaminar configurations: In group EC-1, the membrane was in the center, whereas it was on the surfaces in group EC-2. Specimens were implanted into nude mice for 4 weeks, 8 weeks, 12 weeks, and 8 months and subjected to histologic evaluation and failure testing. RESULTS: In phase I, the results demonstrated that perichondrium securely bonded to the cartilage plays an important role in maintaining the flexible nature of elastic cartilage. In phase II, failure testing revealed that specimens in group EC-1 (expanded polytetrafluoroethylene core) were fractured during bending and destroyed after torsion, whereas those in group EC-2 (cartilage core) returned to their original shape without fracturing even after rigorous torsion. Histologic analysis demonstrated that transplanted chondrocytes penetrated into the microporous structure of expanded polytetrafluoroethylene and created a bond to it. CONCLUSION: It is possible to engineer flexible cartilage using expanded polytetrafluoroethylene as a pseudoperichondrium.

Animals↗

Injectable tissue-engineered cartilage with different chondrocyte sources.

Injectable engineered cartilage that maintains a predictable shape and volume would allow recontouring of craniomaxillofacial irregularities with minimally invasive techniques. This study investigated how chondrocytes from different cartilage sources, encapsulated in fibrin polymer, affected construct mass and volume with time. Swine auricular, costal, and articular chondrocytes were isolated and mixed with fibrin polymer (cell concentration of 40 x 10 cells/ml for all groups). Eight samples (1 cm x 1 cm x 0.3 cm) per group were implanted into nude mice for each time period (4, 8, and 12 weeks). The dimensions and mass of each specimen were recorded before implantation and after explantation. Ratios comparing final measurements and original measurements were calculated. Histological, biochemical, and biomechanical analyses were performed. Histological evaluations (n = 3) indicated that new cartilaginous matrix was synthesized by the transplanted chondrocytes in all experimental groups. At 12 weeks, the ratios of dimension and mass (n = 8) for auricular chondrocyte constructs increased by 20 to 30 percent, the ratios for costal chondrocyte constructs were equal to the initial values, and the ratios for articular chondrocyte constructs decreased by 40 to 50 percent. Constructs made with auricular chondrocytes had the highest modulus (n = 3 to 5) and glycosaminoglycan content (n = 4 or 5) and the lowest permeability value (n = 3 to 5) and water content (n = 4 or 5). Constructs made with articular chondrocytes had the lowest modulus and glycosaminoglycan content and the highest permeability value and water content (p < 0.05). The amounts of hydroxyproline (n = 5) and DNA (n = 5) were not significantly different among the experimental groups (p > 0.05). It was possible to engineer injectable cartilage with chondrocytes from different sources, resulting in neocartilage with different properties. Although cartilage made with articular chondrocytes shrank and cartilage made with auricular chondrocytes overgrew, the injectable tissue-engineered cartilage made with costal chondrocytes was stable during the time periods studied. Furthermore, the biomechanical properties of the engineered cartilage made with auricular or costal chondrocytes were superior to those of cartilage made with articular chondrocytes, in this model.

Animals↗

Analysis of bending behavior of native and engineered auricular and costal cartilage.

A large-deflection elasticity model was used to describe the mechanical behavior of cartilaginous tissues during three-point bending tests. Force-deflection curves were measured for 20-mm long x 4-mm wide x approximately 1-mm thick strips of porcine auricular and costal cartilage. Using a least-squares method with elastic modulus in bending as the only adjustable parameter, data were fit to a model based on the von Karman theory for large deflection of plates. This model described the data well, with an average RMS error of 14.8% and an average R(2) value of 0.98. Using this method, the bending modulus of auricular cartilage (4.6 MPa) was found to be statistically lower (p < 0.05) than that of costal cartilage (7.1 MPa). Material features of the cartilage samples influenced the mechanical behavior, including the orientation of the perichondrium in auricular cartilage. These methods also were used to determine the elastic moduli of engineered cartilage samples produced by seeding chondrocytes into fibrin glue. The modulus of tissue-engineered constructs increased statistically with time (p < 0.05), but still were statistically lower than the moduli of the native tissue samples (p > 0.05), reaching only about a third of the values of native samples.

Animals↗

Biomechanical properties of human articular cartilage under compressive loads.

The function of articular cartilage is to support and distribute loads and to provide lubrication in the diarthrodial joints. Cartilage function is described by proper mechanical and rheological properties, strain and depth-dependent, which are not completely assessed. Unconfined and confined compression are commonly used to evaluate the Young's modulus (E) and the aggregate modulus (H(A)), respectively. The Poisson's ratio (nu) can be calculated indirectly from the equilibrium compression data, or using the biphasic indentation technique; it has recently been optically evaluated by using video microscopy during unconfined compression. The transient response of articular cartilage during confined compression depends on its permeability k; a constant value of k can be easily identified by a simple analytical model of confined compression tests, whereas more complex models or direct measurements (permeation tests) are needed to study the permeability dependence on deformation. A poroelastic finite element model of articular cartilage was developed for this purpose. The elastic parameters (E,nu) of the model were evaluated performing unconfined compression creep tests on human articular cartilage disks, whereas k was identified from the confined test response. Our combined experimental and computational method can be used to identify the parameters that define the permeability dependence on deformation, as a function of depth from articular surface.

Adaptation, Physiological↗

Cell-based bonding of articular cartilage: An extended study.

This study evaluated the biomechanical characteristics of newly formed cartilaginous tissue synthesized from isolated chondrocytes and seeded onto devitalized cartilage in an extended study in vivo. Cartilage from porcine articular joints was cut into regular discs and devitalized by multiple freeze-thaw cycles. Articular chondrocytes were enzymatically isolated and incubated in suspension culture in the presence of devitalized cartilage discs for 21 days. This procedure allowed the isolated chondrocytes to adhere to the devitalized matrix surfaces. Chondrocyte-matrix constructs were assembled with fibrin glue and implanted in dorsal subcutaneous pockets in nude mice for up to 8 months. Histological evaluation and biomechanical testing were performed to quantify the integration of cartilage pieces and the mechanical properties of the constructs over time. Histological analysis indicated that chondrocytes grown on devitalized cartilage discs produced new matrix that bonded and integrated individual cartilage elements with mechanically functional tissue. Biomechanical testing demonstrated a time dependent increase in tensile strength, failure strain, failure energy, and tensile modulus to values 5-30% of normal articular cartilage by 8 months in vivo. The values recorded at 4 months were not statistically different from those collected at the latest time point, indicating that the limits of the biomechanical property values were reached after four months from implantation.

Animals↗

Histomorphometric analysis of a cell-based model of cartilage repair.

This study examined the morphology of chondrocytes in an established model of articular cartilage repair. Articular cartilage was harvested from young sheep and seeded onto pieces of devitalized sheep cartilage. The seeded pieces were stacked in pairs and wrapped in fibrin glue, and then implanted subcutaneously in the dorsum of athymic mice. Samples were harvested after 6 weeks and examined by transmission electron microscopy (TEM) or by light microscopy. TEM revealed that the cells in direct apposition to the devitalized cartilage were elongated, with an enlarged cytoplasm, and a ruffled border. TEM of cells far from the interface with scaffold tissue revealed rounded cells with large nuclei that appeared similar to normal chondrocytes. Quantitative morphometry of histologic specimens revealed that cell area, relative amount of cytoplasm, cell aspect ratio, and relative nuclear displacement were all higher in cells near the interface with the scaffold tissue, and decreased with distance from the interface. These indices of cell morphology are all consistent with an active remodeling of the scaffold at the cell-scaffold interface.

Animals↗

Cell-based therapy for meniscal repair: a large animal study.

BACKGROUND: The avascular portion of the meniscus cartilage in the knee does not have the ability to repair spontaneously. HYPOTHESIS: Cell-based therapy is able to repair a lesion in the swine meniscus. STUDY DESIGN: Controlled laboratory study. METHODS: Sixteen Yorkshire pigs were divided into four groups. A longitudinal tear was produced in the avascular portion of the left medial meniscus of 4 pigs. Autologous chondrocytes were seeded onto devitalized allogenic meniscal slices and were secured inside the lesion with two sutures. Identical incisions were created in 12 other pigs, which were used as three separate control groups: 4 animals treated with an unseeded scaffold, 4 were simply sutured, and 4 were left untreated. Meniscal samples were collected after 9 weeks, and the samples were analyzed grossly, histologically, and histomorphometrically. RESULTS: Gross results showed bonding of the lesion margins in the specimens of the experimental group, whereas no repair was noted in any of the control group specimens. Histological and histomorphometrical analysis showed multiple areas of healing in the specimens of the experimental group. CONCLUSIONS: This study demonstrated the ability of seeded chondrocytes to heal a meniscal tear. CLINICAL RELEVANCE: Cell-based therapy could be a potential tool for avascular meniscus repair.

Animals↗

Poroelastic numerical modelling of natural and engineered cartilage based on in vitro tests.

The mechanisms underlying the ability of articular cartilage to withstand and distribute the loads applied across diarthrodial joints have been widely studied. Experimental tests have been done under several configurations to reveal the tissue response to mechanical stimuli, and theoretical models have been developed for the interpretation of the experimental results. The experiments demonstrated that the tissue is non-linear with strain, both in tension and in compression, non-linear with direction of stimulus, anisotropic in tension and compression, non-homogeneous with depth, resulting in depth dependent mechanical properties, and presents fluid dependent and fluid independent viscoelasticity. None of the models up to now developed is able to describe the whole set of responses of such a complex tissue. The purpose of this study was to develop a combined experimental-numerical approach for the proper description of the cartilage response under confined and unconfined compression. We defined a series of experimental tests to be performed on disks of natural and engineered cartilage and we developed a numerical model for cartilage, based on the biphasic theory, which potentially includes the tension-compression non-linearity, the strain non-linearity and the fluid independent viscoelasticity. The model successfully simulated the confined and unconfined compression experiments performed on disks of natural and engineered cartilage, and was also used to identify parameters of difficult experimental evaluation, such as the collagen stiffness and the permeability. In conclusion, the use of our model in combination with biomechanical experimental testing seems a valuable tool to analyze the mechanical properties of natural cartilage and the biofunctionality of tissue engineered cartilage.

Aged↗